Investigation of the "block effect" on spatial resolution in PET detectors

被引:20
|
作者
Tomic, N [1 ]
Thompson, CJ
Casey, ME
机构
[1] McGill Univ, Jewish Gen Hosp, Dept Radiat Oncol, Montreal, PQ H3T 1E2, Canada
[2] McGill Univ, Dept Phys Med, Montreal, PQ H3T 1E2, Canada
[3] CTI PET Syst Inc, Knoxville, TN 37932 USA
基金
加拿大自然科学与工程研究理事会;
关键词
BGO; block detectors; positron emission tomography (PET); spatial resolution;
D O I
10.1109/TNS.2005.851433
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Previous studies suggest that when block detectors are used in positron emission tomography (PET) scanners, a "block effect" of about 2 mm should be added in quadrature to the other effects blurring spatial resolution (SR). However, no explanation of the cause of the effect has ever been published. If the effect could be identified, isolated, and reduced then the SR of PET scanners should improve. We studied the origin of the "block effect," using experiments in which all other blurring effects on SR were minimized and precisely determined. Thin, 1 mm wide bismuth germanate (BGO) crystals and a small (1 mm) (68)Ge source were used to probe the SR of a HR+ block detector. Two precise translation stages were used to move detectors. We compared coincidence aperture functions (CAFs) for crystals in the block with CAFs of single crystals of various widths. From those measurements, done with one block detector, we concluded that the central crystals in the block showed an additional blurring of 0.8 mm whereas the edge ones showed no additional blurring. When the detectors were separated by 21 cm, the full width at half maximum (FWHM) for central crystals was found to be 2.20 +/- 0.04 mm and for edge crystals 1.98 +/- 0.04 mm. The FWHM for 4.4 mm width crystals (as used in the HR + block) was estimated to be 2.1 +/- 0.2 mm. Results from the crystal identification matrix show that the apparent centroids of the crystals are not located at the geometric centers, which would give errors in the reconstruction algorithm assumed uniform sampling. Our results suggest that the additional blurring previously reported in PET scanners with block detectors is not entirely due to the use of block detectors.
引用
收藏
页码:599 / 605
页数:7
相关论文
共 50 条
  • [21] Efficient one-pair experimental system for spatial resolution demonstration of prototype PET detectors
    Tashima H.
    Yoshida E.
    Hirano Y.
    Nishikido F.
    Inadama N.
    Murayama H.
    Yamaya T.
    Radiological Physics and Technology, 2014, 7 (2) : 379 - 386
  • [22] A Method to Achieve Spatial Linearity and Uniform Resolution at the Edges of Monolithic Scintillation Crystal Detectors for PET
    Vinke, Ruud
    Olcott, Peter D.
    Yearn, Jung Yeol
    Levin, Craig S.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2270 - 2273
  • [23] Spatial resolution of silicon microstrip detectors
    Turchetta, R.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993, A335 (1-2) : 44 - 58
  • [24] Effect of tissue density on PET spatial resolution in magnetic environment
    Chong Li
    Xingzhong Cao
    Fuyan Liu
    Peng Zhang
    Zhiming Zhang
    Long Wei
    Baoyi Wang
    The European Physical Journal Plus, 135
  • [25] Effect of tissue density on PET spatial resolution in magnetic environment
    Li, Chong
    Cao, Xingzhong
    Liu, Fuyan
    Zhang, Peng
    Zhang, Zhiming
    Wei, Long
    Wang, Baoyi
    EUROPEAN PHYSICAL JOURNAL PLUS, 2020, 135 (01):
  • [26] Effect of Spatial Resolution in Modeling Stormwater Runoff for an Urban Block
    Goldstein, Alisha
    Foti, Romano
    Montalto, Franco
    JOURNAL OF HYDROLOGIC ENGINEERING, 2016, 21 (11)
  • [27] Study of the spatial resolution in gamma detectors using photosensitive wire chambers in view of their use as high resolution PET scanners
    Bruyndonckx, P.
    Shuping, Z.
    Tavernier, S.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992, A323 (1-2) : 54 - 59
  • [28] PET investigation of a fluidized particle: spatial and temporal resolution and short term motion
    Hoffmann, AC
    Dechsiri, C
    van de Wiel, F
    Dehling, HG
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (03) : 851 - 858
  • [29] A ∼0.7 mm Spatial Resolution All-digital Animal PET System using Improved Trans-PET Detectors
    Liu, Tong
    Niu, Ming
    Gu, Shuguo
    Xiao, Peng
    Xie, Qingguo
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [30] Experimental Evaluation of System Models for PET with Block Detectors
    Tohme, Michel S.
    Qi, Jinyi
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2778 - 2782