Research on "Rotten Feet" Phenomenon in Cast-in-place Reinforced Concrete Columns of Liu Lu Apartment

被引:0
|
作者
Zhao, Shouyong [1 ]
机构
[1] Sichuan Agr Univ, Coll Civil Engn, Dujiangyan, Sichuan, Peoples R China
来源
2018 INTERNATIONAL CONFERENCE ON COMPUTER, CIVIL ENGINEERING AND MANAGEMENT SCIENCE (ICCEMS 2018) | 2018年
关键词
Drain Holes; Exposed Reinforcement; Prevention; Treatment Measures;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
"Rotten feet" phenomenon, represented by drain holes and exposed reinforcement, occurs in the cast-in-place concrete columns of Liu Lu Apartment. This paper analyzes the reasons of this phenomenon. Main reasons include concrete disintegration, which is represented by mortar and gravel separation; too much concrete unloading at one-time and inadequate vibration; inappropriate selection of concrete mix ratios and others. Corresponding preventive ways and countermeasures are provided in this paper. These methods of prevention and treatment are also applicable to drain holes and exposed reinforcement in beams and plates.