A new method to determine biological sample volume by short end multiple injection capillary electrophoresis: Application in determination of nitrate and thiocyanate in human saliva

被引:27
作者
Vitali, Luciano [1 ]
Favere, Valfredo T. [1 ]
Micke, Gustavo A. [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Chem, BR-88040900 Florianopolis, SC, Brazil
关键词
Short-end multiple injection; Saliva; Nitrate; Thiocyanate; Capillary coated; ZONE-ELECTROPHORESIS; BACKGROUND ELECTROLYTES; CHITOSAN; DRUGS; PRECONCENTRATION; EIGENMOBILITIES; EIGENPEAKS; BIOFLUIDS; NITRITE; FLUIDS;
D O I
10.1016/j.chroma.2011.02.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this study was to develop a simple and rapid method of capillary electrophoresis using a short end multiple injection in free solution to determine simultaneously the biological sample volume and analytes concentration. The method consists of a sequence of injection steps with an internal standard as the reference for correction of the volume of sample collected. The procedure was applies in the determination of NO3- and SCN in saliva samples. The background electrolyte was composed of 12 mM tris(hydroxymethyl)aminomethane and 8.5 mM sulfuric acid, at pH 2.5. The internal standard used was BrO3-. A fused silica capillary (48.5 cm total length, 8.5 cm effective length and 75 mu m i.d.) coated with chitosan was used in a short-end injection configuration. Modification of the electroosmotic flow (EOF) using dynamic coating resulted in a controlled and stable EOF, contributing to the rapid separation of anions (0.36 min) in co-electroosmotic mode. The validation of the method for correcting the volume of saliva collected with a swab showed a difference of less than 3.5% compared with the predicted value and a correlation of 0.999. The limits of detection for NO3- and SCN- were 0.13 and 0.23 mg L-1, respectively. The inter-day precision of the method determined for both analytes was less than 5% and the recovery ranged between 97 and 102%. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2327 / 2333
页数:7
相关论文
共 23 条
[1]   Capillary electrophoresis as a versatile tool for the bioanalysis of drugs - a review [J].
Boone, CM ;
Waterval, JCM ;
Lingeman, H ;
Ensing, K ;
Underberg, WJM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (06) :831-863
[2]   Sample preparation [J].
Chen, Yi ;
Guo, Zhenpeng ;
Wang, Xiaoyu ;
Qiu, Changgui .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) :191-219
[3]   Saliva specimen: A new laboratory tool for diagnostic and basic investigation [J].
Chiappin, Silvia ;
Antonelli, Giorgia ;
Gatti, Rosalba ;
De Palo, Elio F. .
CLINICA CHIMICA ACTA, 2007, 383 (1-2) :30-40
[4]   Ionic interactions between sulfuric acid and chitosan membranes [J].
Cui, Zheng ;
Xiang, Yan ;
Si, Jiangju ;
Yang, Meng ;
Zhang, Qi ;
Zhang, Tao .
CARBOHYDRATE POLYMERS, 2008, 73 (01) :111-116
[5]  
Gas B, 2001, J CHROMATOGR A, V905, P269
[6]   Application of capillary zone electrophoresis to the analysis and to a stability study of nitrite and nitrate in saliva [J].
Gáspár, A ;
Juhász, P ;
Bágyi, K .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1065 (02) :327-331
[7]   Decreasing analysis time in capillary electrophoresis: Validation and comparison of quantitative performances in several approaches [J].
Geiser, L ;
Rudaz, S ;
Veuthey, JL .
ELECTROPHORESIS, 2005, 26 (12) :2293-2302
[8]   Analysis of thiocyanate in biological fluids by capillary zone electrophoresis [J].
Glatz, Z ;
Nováková, S ;
Sterbová, H .
JOURNAL OF CHROMATOGRAPHY A, 2001, 916 (1-2) :273-277
[9]   Heterogeneous catalysis on chitosan-based materials: a review [J].
Guibal, E .
PROGRESS IN POLYMER SCIENCE, 2005, 30 (01) :71-109
[10]   Preparation and evaluation of stable coating for capillary electrophoresis using coupled chitosan as coated modifier [J].
Huang, XJ ;
Wang, QQ ;
Huang, BL .
TALANTA, 2006, 69 (02) :463-468