A Novel Approach for Optimal PMU Placement Considering Channel Limit

被引:0
|
作者
Rokkamand, Venkatesh [1 ]
Bhimasingu, Ravikumar [2 ]
机构
[1] Crompton Greaves Ltd, Global R&D Ctr, Bombay 400040, Maharashtra, India
[2] Indian Inst Technol Hyderabad, Dept Elect Engn, Hyderabad 502205, Andhra Pradesh, India
关键词
phasor measurement units; channel limit; zero injections; binary integer linear programming;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a simple approach for finding the optimal placement of Phasor Measurement Units (PMUs) considering bus connectivity matrix and line connectivity matrix. The approach apart from minimizing number of PMUs also minimizes the number of branch current phasors. In this approach, a method is proposed in which the OPP problem is solved while considering PMUs with limit on the number of channels. Conventional Binary Integer Linear Programming (BILP) is adopted to solve the optimization problem. The approach guarantees the optimum number of PMUs and minimum number of channels. The proposed approach is illustrated on a sample 7-bus system and extended to IEEE 14-bus, IEEE 24-bus, IEEE 30-bus, New England 39-bus, IEEE 57-bus and IEEE 118-bus systems for illustration purpose.
引用
收藏
页码:1164 / 1171
页数:8
相关论文
共 50 条
  • [1] Optimal PMU Placement for Numerical Observability Considering Fixed Channel Capacity-A Semidefinite Programming Approach
    Manousakis, Nikolaos M.
    Korres, George N.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (04) : 3328 - 3329
  • [2] Optimal PMU placement considering topology constraints
    Zhao, Yuanyuan
    Yuan, Peng
    Ai, Qian
    Lv, Tianguang
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 73 : 240 - 248
  • [3] Optimal PMU Placement Using Binary SOS Considering Measurement Redundancy and Channel Limitations
    Chatterjee, Soumesh
    Roy, Biman Kumar Saha
    2018 20TH NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2018,
  • [4] Multiple channel PMU placement considering communication constraints
    Miljanić Z.
    Djurović I.
    Vujošević I.
    Energy Systems, 2013, 4 (02) : 125 - 135
  • [5] Optimal PMU Placement Considering Data Integrity Attack
    Gao, Ziqin
    Li, Jianing
    2022 IEEE 16TH INTERNATIONAL CONFERENCE ON COMPATIBILITY, POWER ELECTRONICS, AND POWER ENGINEERING (CPE-POWERENG), 2022,
  • [6] Multistage Optimal PMU Placement Considering Substation Infrastructure
    Almasabi, Saleh
    Mitra, Joydeep
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (06) : 6519 - 6528
  • [7] Optimal Placement of PMU's Considering Sensitivity Analysis
    Yammani, Chandrasekhar
    Reddy, Narsi K.
    Maheswarapu, Sydulu
    PROCEEDINGS OF IEEE INTERNATIONAL CONFERENCE ON TECHNOLOGICAL ADVANCEMENTS IN POWER AND ENERGY, 2015, : 40 - 44
  • [8] A modified optimal PMU placement problem formulation considering channel limits under various contingencies
    Shafiullah, Md
    Hossain, Md Ismail
    Abido, M. A.
    Abdel-Fattah, Taher
    Mantawy, A. H.
    MEASUREMENT, 2019, 135 : 875 - 885
  • [9] Optimal co-placement method considering non-homogeneous PMU channel capacities
    Okekunle, Dahunsi J.
    Unigwe, Obinna
    Kiprakis, Aristides E.
    IET SMART GRID, 2020, 3 (05) : 626 - 637
  • [10] Observability Constrained GA Approach for Optimal PMU Placement considering Zero Injection Modeling
    Sushma, G. Chandana
    Jyothsna, T. R.
    2018 INTERNATIONAL CONFERENCE ON CONTROL, POWER, COMMUNICATION AND COMPUTING TECHNOLOGIES (ICCPCCT), 2018, : 174 - 178