Electrocardiography Screening for Hypertrophic Cardiomyopathy

被引:8
作者
Campbell, Matthew J. [1 ]
Zhou, Xuefu [2 ]
Han, Chia [2 ]
Abrishami, Hedayat [2 ]
Webster, Gregory [3 ]
Miyake, Christina Y. [4 ]
Knilans, Timothy K. [5 ]
Czosek, Richard J. [5 ]
机构
[1] Cincinnati Childrens Hosp Med Ctr, Dept Pediat, Cincinnati, OH 45229 USA
[2] Univ Cincinnati, Coll Engn & Appl Sci, Dept Elect Engn & Comp Syst, Cincinnati, OH USA
[3] Ann & Robert H Lurie Childrens Hosp Chicago, Dept Pediat, Div Cardiol, Chicago, IL 60611 USA
[4] Texas Childrens Hosp, Dept Pediat, Cardiol Sect, Houston, TX 77030 USA
[5] Cincinnati Childrens Hosp Med Ctr, Dept Pediat, Inst Heart, Div Pediat Cardiol, Cincinnati, OH 45229 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2016年 / 39卷 / 09期
关键词
hypertrophic cardiomyopathy; ECG screening; Seattle Criteria; SUDDEN CARDIAC DEATH; AMERICAN-HEART-ASSOCIATION; COLLEGE-OF-CARDIOLOGY; CARDIOVASCULAR-ABNORMALITIES; SCIENTIFIC STATEMENT; ECG; CHILDREN; CRITERIA; ECHOCARDIOGRAM; ADOLESCENTS;
D O I
10.1111/pace.12913
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundHypertrophic cardiomyopathy (HCM) is the leading cause of sudden cardiac death in athletes. However, preparticipation electrocardiogram (ECG) screening has been criticized for failing to meet cost-effectiveness thresholds, in part because of high false-positive rates. We sought to evaluate whether a highly automated software algorithm could be used for a high throughput, population-based screening program and address several of the limitations seen with population-based screening MethodsA proprietary computed algorithm was created based on both voltage- as well as Seattle-based ECG criteria. Different cut points for Q-wave depth, Q-wave length, the degree of ST depression, the degree of T-wave inversion, and left ventricular voltage were analyzed for optimum sensitivity and specificity. After developing receiver operating characteristic curves for each criterion, different cut points were trialed together on our data set to obtain settings to optimize sensitivity and specificity. ResultsThe automated algorithm was capable of identifying patients with HCM based on ECG with 88.6% sensitivity and 98% specificity, compared to a sensitivity of 90.2% and specificity of 96% when the ECGs were read by physicians according to the Seattle Criteria. Adding voltage criteria improved the sensitivity of the algorithm with a mild decrease in specificity. Optimum sensitivity with this automated software was 98%; optimum specificity was 96%. ConclusionComputer-automated ECG screening for HCM is feasible. Evaluation of automated ECG algorithms in larger and more diverse populations is warranted.
引用
收藏
页码:944 / 950
页数:7
相关论文
共 22 条
[1]   Usefulness of Combined History, Physical Examination, Electrocardiogram, and Limited Echocardiogram in Screening Adolescent Athletes for Risk for Sudden Cardiac Death [J].
Anderson, Jeffrey B. ;
Grenier, Michelle ;
Edwards, Nicholas M. ;
Madsen, Nicolas L. ;
Czosek, Richard J. ;
Spar, David S. ;
Barnes, Allison ;
Pratt, Jesse ;
King, Eileen ;
Knilans, Timothy K. .
AMERICAN JOURNAL OF CARDIOLOGY, 2014, 114 (11) :1763-1767
[2]   Modest agreement in ECG interpretation limits the application of ECG screening in young athletes [J].
Brosnan, Maria ;
La Gerche, Andre ;
Kumar, Saurabh ;
Lo, Wilson ;
Kalman, Jonathan ;
Prior, David .
HEART RHYTHM, 2015, 12 (01) :130-136
[3]   The Seattle Criteria increase the specificity of preparticipation ECG screening among elite athletes [J].
Brosnan, Maria ;
La Gerche, Andre ;
Kalman, Jon ;
Lo, Wilson ;
Fallon, Kieran ;
MacIsaac, Andrew ;
Prior, David .
BRITISH JOURNAL OF SPORTS MEDICINE, 2014, 48 (15) :1144-1150
[4]   NORMAL ECG STANDARDS FOR INFANTS AND CHILDREN [J].
DAVIGNON, A ;
RAUTAHARJU, P ;
BOISSELLE, E ;
SOUMIS, F ;
MEGELAS, M ;
CHOQUETTE, A .
PEDIATRIC CARDIOLOGY, 1980, 1 (02) :123-131
[5]   An efficient new method for the detection of QRS in electrocardiogram [J].
Dohare, Ashok Kumar ;
Kumar, Vinod ;
Kumar, Ritesh .
COMPUTERS & ELECTRICAL ENGINEERING, 2014, 40 (05) :1717-1730
[6]   Cardiovascular screening in adolescents and young adults: a prospective study comparing the Pre-participation Physical Evaluation Monograph 4th Edition and ECG [J].
Fudge, Jessie ;
Harmon, Kimberly G. ;
Owens, David S. ;
Prutkin, Jordan M. ;
Salerno, Jack C. ;
Asif, Irfan M. ;
Haruta, Alison ;
Pelto, Hank ;
Rao, Ashwin L. ;
Toresdahl, Brett G. ;
Drezner, Jonathan A. .
BRITISH JOURNAL OF SPORTS MEDICINE, 2014, 48 (15) :1172-1178
[7]   Correlation of Precordial Voltages to Left Ventricular Mass on Echocardiogram in Adolescent Patients With Hypertrophic Cardiomyopathy Compared With that in Adolescent Athletes [J].
Guerrier, Karine ;
Anderson, Jeffrey B. ;
Pratt, Jesse ;
King, Eileen C. ;
Statile, Christopher ;
Wilmot, Ivan ;
Campbell, Matthew ;
Czosek, Richard J. .
AMERICAN JOURNAL OF CARDIOLOGY, 2015, 115 (07) :956-961
[8]   Discrete Wavelet-Aided Delineation of PCG Signal Events via Analysis of an Area Curve Length-Based Decision Statistic [J].
Homaeinezhad, M. R. ;
Atyabi, S. A. ;
Daneshvar, E. ;
Ghaffari, A. ;
Tahmasebi, M. .
CARDIOVASCULAR ENGINEERING, 2010, 10 (04) :218-234
[9]   Real-time electrocardiogram P-QRS-T detection-delineation algorithm based on quality-supported analysis of characteristic templates [J].
Karimipour, Atiyeh ;
Homaeinezhad, Mohammad Reza .
COMPUTERS IN BIOLOGY AND MEDICINE, 2014, 52 :153-165
[10]   Recommendations and considerations related to preparticipation screening for cardiovascular abnormalities in competitive athletes: 2007 update a scientific statement from the American Heart Association Council on Nutrition, Physical Activity, and Metabolism - Endorsed by the American College of Cardiology Foundation [J].
Maron, Barry J. ;
Thompson, Paul D. ;
Ackerman, Michael J. ;
Balady, Gary ;
Berger, Stuart ;
Cohen, David ;
Dimeff, Robert ;
Douglas, Pamela S. ;
Glover, David W. ;
Hutter, Adolph M., Jr. ;
Krauss, Michael D. ;
Maron, Martin S. ;
Mitten, Matthew J. ;
Roberts, William O. ;
Puffer, James C. .
CIRCULATION, 2007, 115 (12) :1643-1655