Application of capillary electrophoresis-inductively coupled plasma mass spectrometry to trace elemental speciation analysis

被引:0
作者
Kang, JZ [1 ]
Duan, TC [1 ]
Liu, J [1 ]
Zeng, XJ [1 ]
Chen, HT [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, Natl Analyt Res Ctr Electrochem & Spect, State key Lab Electroanalyt Chem, Changchun 130022, Peoples R China
关键词
capillary electrophoresis; inductively coupled plasma mass spectrometry; elemental-speciation analysis; review;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The importance-and development of elemental-speciation analysis were elucidated and reviewed. Based on these, particular attentions were focused on those related to the technique of capillary electrophoresis (CE) inductively coupled plasma mass spectrometry (CE-ICP-MS) that was recently applied to trace elemental-speciation analysis, including different designs of the critical interface of ICP-MS with CE, main factors that affect the discrimination of CE and the analytical sensitivity, and discussions on the potential limits and developing trends of this kind of technique applied in elemental-speciation analysis.
引用
收藏
页码:1385 / 1392
页数:8
相关论文
共 85 条
[1]  
[Anonymous], 1988, METAL SPECIATION THE
[2]   The role of element speciation in environmental and occupational medicine [J].
Apostoli, P .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (5-6) :499-504
[3]   Evaluation of a microconcentric nebulizer and its suction effect in a capillary electrophoresis interface with inductively coupled plasma mass spectrometry [J].
B'Hymer, C ;
Day, JA ;
Caruso, JA .
APPLIED SPECTROSCOPY, 2000, 54 (07) :1040-1046
[4]   The use of sol-gel frits to minimize suction effects in capillary electrophoresis-nebulizer interfaces for plasma spectrometry [J].
B'Hymer, C ;
Sutton, RMC ;
Sutton, KL ;
Caruso, JA .
ANALYTICAL COMMUNICATIONS, 1999, 36 (9-10) :349-353
[5]   Comparison of a cross-flow and microconcentric nebulizer for chemical speciation measurements using CZE-ICP-MS [J].
Baker, SA ;
Miller-Ihli, NJ .
APPLIED SPECTROSCOPY, 1999, 53 (04) :471-478
[6]   Capillary electrophoresis and inductively coupled plasma spectrometry: Status report [J].
Barnes, RM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03) :246-251
[7]  
BATLEY GE, 1987, TRACE ELEMENT SPECIA
[8]   The use of radiofrequency glow discharge-mass spectrometry (rf-GD-MS) coupled to gas chromatography for the determination of selenoaminoacids in biological samples [J].
Bayón, MM ;
B'Hymer, C ;
de León, CAP ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (05) :492-497
[9]   THE ROLE OF SUPERCRITICAL-FLUID EXTRACTION AND CHROMATOGRAPHY IN ORGANOTIN SPECIATION STUDIES [J].
BAYONA, JM ;
CAI, Y .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (08) :327-332