The quantitative impact of the mesopore size on the mass transfer mechanism of the new 1.9 μm fully porous Titan-C18 particles II - Analysis of biomolecules

被引:14
作者
Gritti, Fabrice [1 ]
Guiochon, Georges [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
关键词
Protein analysis; Column efficiency; Average pore size; Sub-2 mu m Titan-C-18 particles; Bradykinin; Insulin; ESTIMATING DIFFUSION-COEFFICIENTS; LIQUID-CHROMATOGRAPHY; SHELL PARTICLES; EXCLUSION CHROMATOGRAPHY; SILICA PARTICLES; PACKING MATERIAL; PERFORMANCE; DISPERSION; COLUMNS; PHASE;
D O I
10.1016/j.chroma.2015.02.075
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The kinetic performances of 3.0 x 100 mm columns packed with 1.9 mu m Titan-C-18 particles with average mesopore sizes of 80 angstrom and 120 angstrom were investigated quantitatively for the analysis of biomolecules Large mesopores are expected to speed up the rate of diffusivity of high-molecular-weight compounds across the stationary phase and to generate higher plate counts at high velocities. The mass transfer mechanism of bradykinin acetate salt (1060 Da) and insulin (5733 Da) was determined over a range of flow rates from 0.025 to 1.0 mL/min. The pore diffusivities of these two biomolecules were accurately measured from the peak parking method. Even though the gain in column efficiency was not found significant for small molecules such as valerophenone (162 Da), enlarging the average pore size from 80 to 120 angstrom induces a measurable diminution of the reduced plate height, h, of bradykinin (from 17 to 11 or -35% at a reduced velocity of 50) and a significant reduction for insulin (from 43 to 12 or -72% at a reduced velocity of 90). Remarkably, while the increase of the column efficiency for bradykinin is consistent with a faster diffusivity of bradykinin across the 120 angstrom Titan-C-18 particles, the higher column efficiencies measured for insulin are mostly due to a faster absorption kinetics into the 120 angstrom than that into the 80 angstrom Titan-C-18 particles. This result is supported by the fact that the effective pore diffusivity of insulin is even slightly smaller across the 120 angstrom than that across the 80 angstrom 1.9 mu m Titan-C-18 particles. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 19
页数:10
相关论文
共 39 条
[11]   Effect of the surface coverage of C18-bonded silica particles on the obstructive factor and intraparticle diffusion mechanism [J].
Gritti, Fabrice ;
Guiochon, Georges .
CHEMICAL ENGINEERING SCIENCE, 2006, 61 (23) :7636-7650
[12]   The quantitative impact of the mesopore size on the mass transfer mechanism of the new 1.9 μm fully porous Titan-C18 particles. I: Analysis of small molecules [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1384 :76-87
[13]   Particle size distribution and column efficiency. An ongoing debate revived with 1.9 μm Titan-C18 particles [J].
Gritti, Fabrice ;
Bell, David S. ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1355 :179-192
[14]   The rationale for the optimum efficiency of columns packed with new 1.9 μm fully porous Titan-C18 particles-A detailed investigation of the intra-particle diffusivity [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1355 :164-178
[15]   Realization and potential advantages of gradient separations performed under steady state temperature regime [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1291 :104-113
[16]   Optimization of the peak capacity per unit time [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1263 :125-140
[17]   Overload behavior and apparent efficiencies in chromatography [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1254 :30-42
[18]   On the relationship between band broadening and the particle-size distribution of the packing material in liquid chromatography: Theory and practice. [J].
Gritti, Fabrice ;
Farkas, Tivadar ;
Heng, Josuah ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (45) :8209-8221
[19]   Mass transfer kinetics, band broadening and column efficiency [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1221 :2-40
[20]   Mass transfer mechanism in liquid chromatography columns packed with shell particles: Would there be an optimum shell structure? [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (52) :8167-8180