Dosimetric evaluation of the mean glandular dose for mammography in Korean women: A preliminary report

被引:6
作者
Oh, KK
Hur, J
Kim, EK
Choo, SS
机构
[1] Yonsei Univ, Coll Med, Res Inst Radiol Sci, Dept Diagnost Radiol, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Dept Radiat Oncol, Seoul, South Korea
关键词
radiation; mammography; dosimetry; phantom;
D O I
10.3349/ymj.2003.44.5.863
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to evaluate the thickness of the compressed breast in mediolateral oblique (MLO) and craniocaudal (CC) mammograms, to relate these thickness and breast patterns to mean glandular dose (MGD) in Korean women, and to evaluate the suitability of using the American College of Radiology's Recommendations for Korean women from a quality assurance standpoint. The study population consisted of 92 paired MLO and CC mammograms obtained on one mammographic unit. The digital readouts of compressed breast thickness, applied compression force and tube voltage were recorded. Entrance skin exposure was measured by dosimetry. MGD was calculated by multiplying entrance skin exposure by the exposure-to-absorbed dose conversion factor. The range of breast thickness was 1.3 - 6.2 cm in CC mammograms with a mean breast thickness of 3.6 cm, and 1.6 - 6.5 cm in MLO mammograms with a mean breast thickness of 3.9 cm. MGDs in CC and MLO mammograms were. 1.77 mSv and 1.88 mSv per view, respectively. Breast composition patterns were divided into 4 groups according to ACR BI-RADS; P1. (n=20), P2 (n=16), P3 (n=48) and P4 (n=8). The MGDs for these groups were: 1.82, 1.84, 1.84, and 1.91 mSv, respectively. When subjects were subdivided by breast thickness into three groups, namely, below 3 cm, 3 cm to 4.2 cm, aaa and above 4.2 cm, the corresponding MGDs were 1.83, 1.86, and 1.91 mSv. According to our initial trial, the mean breast thickness and the MGDs of Korean women are lower than recommended by the American College of Radiology, which are commonly used for quality assurance purposes.
引用
收藏
页码:863 / 868
页数:6
相关论文
共 16 条
[1]  
[Anonymous], 1999, MAMMOGRAPHY QUALITY
[2]  
[Anonymous], 1980, EFF POP EXP LOW LEV
[3]   A pilot survey of radiation doses received in the United Kingdom breast screening programme [J].
Burch, A ;
Goodman, DA .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (845) :517-527
[4]   Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol [J].
Dance, DR ;
Skinner, CL ;
Young, KC ;
Beckett, JR ;
Kotre, CJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) :3225-3240
[5]   MONTE-CARLO CALCULATION OF CONVERSION FACTORS FOR THE ESTIMATION OF MEAN GLANDULAR BREAST DOSE [J].
DANCE, DR .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (09) :1211-1219
[6]   ESTIMATION OF RADIATION RISK FROM SCREENING MAMMOGRAPHY - RECENT TRENDS AND COMPARISON WITH EXPECTED BENEFITS [J].
FEIG, SA ;
EHRLICH, SM .
RADIOLOGY, 1990, 174 (03) :638-647
[7]   TLD measurements of in vivo mammographic exposures and the calculated mean glandular dose across the United States [J].
Gentry, JR ;
DeWerd, LA .
MEDICAL PHYSICS, 1996, 23 (06) :899-903
[8]   BREAST THICKNESS IN ROUTINE MAMMOGRAMS - EFFECT ON IMAGE QUALITY AND RADIATION-DOSE [J].
HELVIE, MA ;
CHAN, HP ;
ADLER, DD ;
BOYD, PG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (06) :1371-1374
[9]  
Kim SH, 2000, J KOREAN RADIOL SOC, V42, P1009
[10]   A survey of clinical factors and patient dose in mammography [J].
Kruger, RL ;
Schueler, BA .
MEDICAL PHYSICS, 2001, 28 (07) :1449-1454