Quality assessment for CT colonography: Validation of automated measurement of colonic distention and residual fluid

被引:10
作者
Deshpande, Keshav K.
Summers, Ronald M.
Van Uitert, Robert L.
Franaszek, Marek
Brown, Linda
Dwyer, Andrew J.
Fletcher, Joel G.
Choi, J. Richard
Pickhardt, Perry J.
机构
[1] NIH, Ctr Clin, Dept Diagnost Radiol, Bethesda, MD 20892 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN USA
[3] Uniformed Serv Univ Hlth Sci, Walter Reed Army Med Ctr, Dept Radiol, Washington, DC USA
[4] Univ Wisconsin, Sch Med, Dept Radiol, Madison, WI USA
关键词
colon; colonography; CT; quality; virtual colonoscopy;
D O I
10.2214/AJR.07.2327
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to validate automated quality assessment (QA) software for CT colonography (CTC) by comparing results obtained with the software with results of interpretation by radiologists in the assessment of colonic distention and surface area obscured by residual fluid. MATERIALS AND METHODS. CTC scans of 30 patients were selected retrospectively to span ranges of luminal distention (well distended to poorly distended) and surface area covered by residual fluid (high amount of coverage to low amount of coverage). We used QA software developed in our laboratory to automatically measure the mean distention of each of five colonic segments (ascending, transverse, descending, sigmoid, and rectum). Three experienced radiologists visually graded each scan for distention and fluid coverage. Distention and fluid scores for specific segments were assessed with Bland-Altman analysis (mean difference with 95% limits of agreement) and the weighted kappa test. Interobserver and intraobserver variability was determined with the weighted kappa test. RESULTS. For distention scoring, the mean difference between radiologists and the QA software was 0.1% (95% limits of agreement, -25.6% and 25.9%). For fluid scoring, the mean difference was -0.6% (95% limits of agreement, -8.2% and 7.1%). There was moderate to good agreement (weighted kappa value, 0.50 - 0.78) between the radiologists' mean scores and the scores obtained with the QA software and for interreader and intrareader assessments of distention and fluid coverage. CONCLUSION. Results with the QA software agreed with radiologists' assessment of colonic distention and residual fluid coverage but were a more objective assessment. Use of this QA software can help standardize two important factors, distention and residual fluid coverage, that affect the quality of CTC, reducing two known causes of poor CTC performance.
引用
收藏
页码:1457 / 1463
页数:7
相关论文
共 18 条
[11]   Meta-analysis: Computed tomographic colonography [J].
Mulhall, BP ;
Veerappan, GR ;
Jackson, JL .
ANNALS OF INTERNAL MEDICINE, 2005, 142 (08) :635-650
[12]   False-negative results at multi-detector row CT colonography: Multivariate analysis of causes for missed lesions [J].
Park, SH ;
Ha, HK ;
Kim, MJ ;
Kim, KW ;
Kim, AY ;
Yang, DH ;
Lee, MG ;
Kim, PN ;
Shin, YM ;
Yang, SK ;
Myung, SJ ;
Min, YI .
RADIOLOGY, 2005, 235 (02) :495-502
[13]   Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults [J].
Pickhardt, PJ ;
Choi, JR ;
Hwang, I ;
Butler, JA ;
Puckett, ML ;
Hildebrandt, HA ;
Wong, RK ;
Nugent, PA ;
Mysliwiec, PA ;
Schindler, WR .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (23) :2191-2200
[14]   Quality in the technical performance of colonoscopy and the continuous quality improvement process for colonoscopy: Recommendations of the US Multi-Society Task Force on Colorectal Cancer [J].
Rex, DK ;
Bond, JH ;
Winawer, S ;
Levin, TR ;
Burt, RW ;
Johnson, DA ;
Kirk, LM ;
Litlin, S ;
Lieberman, DA ;
Waye, JD ;
Church, J ;
Marshall, JB ;
Riddell, RH .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2002, 97 (06) :1296-1308
[15]   Patient-controlled room air insufflation versus automated carbon dioxide delivery for CT colonography [J].
Shinners, TJ ;
Pickhardt, PJ ;
Taylor, AJ ;
Jones, DA ;
Olsen, CH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :1491-1496
[16]   Optimizing colonic distention for multi-detector row CT colonography: Effect of hyoscine butylbromide and rectal balloon catheter [J].
Taylor, SA ;
Halligan, S ;
Goh, V ;
Morley, S ;
Bassett, P ;
Atkin, W ;
Bartram, CI .
RADIOLOGY, 2003, 229 (01) :99-108
[17]  
VANUITERT R, 2006, P SPIE MED IMAGING 2, V6143, P434
[18]   The usefulness of glucagon hydrochloride for colonic distention in CT colonography [J].
Yee, J ;
Hung, RK ;
Akerkar, GA ;
Wall, SD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (01) :169-172