Low cost portable 3-D printed optical fiber sensor for real-time monitoring of lower back bending

被引:9
作者
Kam, Wern [1 ]
O'Sullivan, Kieran [2 ,4 ]
O'Keeffe, Mary [2 ]
O'Keeffe, Sinead [1 ]
Mohammed, Waleed S. [3 ]
Lewis, Elfed [1 ]
机构
[1] Univ Limerick, Dept Elect & Comp Engn, Opt Fibre Sensors Res Ctr, Limerick, Ireland
[2] Univ Limerick, Dept Clin Therapies, Limerick, Ireland
[3] Bangkok Univ, Sch Engn, Ctr Res Optoelect Commun & Control Syst BU CROCCS, Pathum Thani 12120, Thailand
[4] Aspetar Orthopaed & Sports Med Hosp, Sports Spine Ctr, Doha, Qatar
关键词
Optical fiber sensor; 3-D printed sensor; Lower back bending sensor; Lateral and sagittal plane motions; LUMBAR SPINE; POSTURE; RELIABILITY; POSITIONS; ROTATION; FLEXION;
D O I
10.1016/j.sna.2017.08.044
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A mechanically robust and compact novel optical fiber sensor systernis described to monitor the bending of the lower backbone in both sagittal and frontal planes. Both bending modes are monitored through the change of the coupled optical intensity ratio between three output fibers aligned to one input fiber. This provides real-time feedback to the clinical therapist when different postures are sustained. The output ratio is calibrated against bending angle using an optical setup utilizing a precise rotational stage. The measured data is also correlated to the curvature of the lower back through the implementation of an ad-hoc imaging scheme. Sequences of images are also captured while the optical fiber sensor is attached on the skin surface to the lower back. The imaging system tracks three spots placed on the sensor and skin to trace the angle changes. The optical fiber sensor system has an operational range between -12 degrees to +12 degrees. It is demonstrated that the sensor is suitable for clinical use with the additional benefits of being non-invasive, robust, straightforward to use and low cost. It also allows record of spinal curvature in the home and other real-world settings and potentially reduces the requirement for the use of X-rays and MRI in the clinic. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:193 / 201
页数:9
相关论文
共 17 条
[1]   A reliable low-cost wireless and wearable gait monitoring system based on a plastic optical fibre sensor [J].
Bilro, L. ;
Oliveira, J. G. ;
Pinto, J. L. ;
Nogueira, R. N. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (04)
[2]   RELIABILITY AND VALIDITY OF 4 INSTRUMENTS FOR MEASURING LUMBAR SPINE AND PELVIC POSITIONS [J].
BURDETT, RG ;
BROWN, KE ;
FALL, MP .
PHYSICAL THERAPY, 1986, 66 (05) :677-684
[3]   Evaluation of lumbar spine motion with dynamic X-ray -: A reliability analysis [J].
Cakir, Balkan ;
Richter, Marcus ;
Kaefer, Wolfram ;
Wieser, Michael ;
Puhl, Wolfhart ;
Schmidt, Rene .
SPINE, 2006, 31 (11) :1258-1264
[4]   Differences in sitting postures are associated with nonspecific chronic low back pain disorders when patients are subclassified [J].
Dankaerts, W ;
O'Sullivan, P ;
Burnett, A ;
Straker, LM .
SPINE, 2006, 31 (06) :698-704
[5]  
Davis Patricia C, 2009, J Am Coll Radiol, V6, P401, DOI 10.1016/j.jacr.2009.02.008
[6]  
Deyo R, 1994, BACK PAIN PATIENT OU
[7]   A simple device to monitor flexion and lateral bending of the lumbar spine [J].
Donatell, GJ ;
Meister, DW ;
O'Brien, JR ;
Thurlow, JS ;
Webster, JG ;
Salvi, FJ .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2005, 13 (01) :18-23
[8]  
Dunne LE, 2006, TENTH IEEE INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS, PROCEEDINGS, P65
[9]   Rasterstereographic analysis of axial back surface rotation in standing versus forward bending posture in idiopathic scoliosis [J].
Hackenberg, Lars ;
Hierholzer, Eberhard ;
Bullmann, Viola ;
Liljenqvist, Ulf ;
Goetze, Christian .
EUROPEAN SPINE JOURNAL, 2006, 15 (07) :1144-1149
[10]   ACCURACY OF MEASURING LATERAL FLEXION OF THE SPINE WITH A TAPE [J].
MELLIN, GP .
CLINICAL BIOMECHANICS, 1986, 1 (02) :85-89