A post-occupancy study of ventilation effectiveness from high-resolution CO2 monitoring at live theatre events to mitigate airborne transmission of SARS-CoV-2

被引:14
作者
Adzic, Filipa [1 ]
Roberts, Ben M. [2 ]
Hathway, Elizabeth Abigail [3 ]
Matharu, Rupy Kaur [1 ]
Ciric, Lena [1 ]
Wild, Oliver [1 ]
Cook, Malcolm [2 ]
Malki-Epshtein, Liora [1 ]
机构
[1] UCL, Dept Civil Environm & Geomat Engn, London, England
[2] Loughborough Univ, Sch Architecture, Bldg Energy Res Grp, Bldg & Civil Engn, Loughborough, England
[3] Univ Sheffield, Dept Civil & Struct Engn, Sheffield, England
基金
英国工程与自然科学研究理事会;
关键词
Theatres; Ventilation; IAQ; SARS-CoV-2; Long-range transmission; Microbiology; THERMAL COMFORT; INDOOR ENVIRONMENTS; LECTURE THEATER; SYSTEM; RISK;
D O I
10.1016/j.buildenv.2022.109392
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Mass-gathering events were closed around the world in 2020 to minimise the spread of the SARS-CoV-2 virus. Emerging research on the transmission of SARS-CoV-2 emphasised the importance of sufficient ventilation. This paper presents the results of an indoor air quality (IAQ) monitoring study over 82 events in seven mechanically ventilated auditoria to support the UK government Events Research Programme. Indoor carbon dioxide con-centration was measured at high resolution before, during, and after occupancy to allow for assessment of the ventilation systems. Generally, good indoor air quality was measured in all auditoria, with average IAQ found to be excellent or very good for 70% of spaces. In some auditoria, spatial variation in IAQ was identified, indicating poor mixing of the air. In addition, surface and air samples were taken and analysed for the presence of bacteria by culture and SARS-CoV-2 using RT-qPCR in one venue. SARS-CoV-2 RNA was detected on a small number of surfaces at very low copy numbers, which are unlikely to pose an infection risk. Under the ventilation strategies and occupancy levels investigated, it is likely that most theatres pose a low risk of long-range transmission of COVID-19.
引用
收藏
页数:18
相关论文
共 50 条
[1]  
ACCLiverpool, 2022, VEN
[2]  
AEA, 2021, INVESTOPEDIA
[3]   Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review [J].
Ai, Z. T. ;
Melikov, A. K. .
INDOOR AIR, 2018, 28 (04) :500-524
[4]   Comparison of SARS-CoV-2 N gene real-time RT-PCR targets and commercially available mastermixes [J].
Brown, Julianne R. ;
O'Sullivan, Denise M. ;
Shah, Divya ;
Atkinson, Laura ;
Pereira, Rui P. A. ;
Whale, Alexandra S. ;
Busby, Eloise J. ;
Huggett, Jim F. ;
Harris, Kathryn .
JOURNAL OF VIROLOGICAL METHODS, 2021, 295
[5]  
CEN,, 2017, ISO Standard EN 16798-7:2017, DOI DOI 10.3403/BSEN16798
[6]  
Centers for Disease Control and Prevention, 2020, CLEANING DISINFECTIO
[7]   Stratified air distribution systems in a large lecture theatre: A numerical method to optimize thermal comfort and maximize energy saving [J].
Cheng, Yuanda ;
Niu, Jianlei ;
Gao, Naiping .
ENERGY AND BUILDINGS, 2012, 55 :515-525
[8]   Thermal comfort study of an air-conditioned lecture theatre in the tropics [J].
Cheong, KWD ;
Djunaedy, E ;
Chua, YL ;
Tham, KW ;
Sekhar, SC ;
Wong, NH ;
Ullah, MB .
BUILDING AND ENVIRONMENT, 2003, 38 (01) :63-73
[9]  
*CIBSE, 2015, CIBSE GUIDE A ENVIRO
[10]   Mass Events Trigger Malta's Second Peak After Initial Successful Pandemic Suppression [J].
Cuschieri, Sarah ;
Balzan, Martin ;
Gauci, Charmaine ;
Aguis, Steve ;
Grech, Victor .
JOURNAL OF COMMUNITY HEALTH, 2021, 46 (03) :618-625