Distinguishing sleep from wake with a radar sensor: a contact-free real-time sleep monitor

被引:12
|
作者
Heglum, Hanne Siri Amdahl [1 ,2 ]
Kallestad, Havard [4 ,5 ]
Vethe, Daniel [4 ,5 ]
Langsrud, Knut [4 ,5 ]
Sand, Trond [1 ,3 ]
Engstrom, Morten [1 ,3 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Neuromed & Movement Sci, Trondheim, Norway
[2] Novelda AS, Trondheim, Norway
[3] St Olavs Univ Hosp, Dept Neurol & Clin Neurophysiol, Trondheim, Norway
[4] Norwegian Univ Sci & Technol, Dept Mental Hlth, Trondheim, Norway
[5] St Olavs Univ Hosp, Div Mental Hlth Care, Trondheim, Norway
关键词
sleep; radar; actigraphy; polysomnography; sleep monitoring; ambulatory home monitoring; PRACTICE PARAMETERS; WRIST ACTIGRAPHY; POLYSOMNOGRAPHY; VALIDATION; NONINFERIORITY; ALGORITHM; MEDICINE; QUALITY; MOTION;
D O I
10.1093/sleep/zsab060
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This work aimed to evaluate whether a radar sensor can distinguish sleep from wakefulness in real time. The sensor detects body movements without direct physical contact with the subject and can be embedded in the roof of a hospital room for completely unobtrusive monitoring. We conducted simultaneous recordings with polysomnography, actigraphy, and radar on two groups: healthy young adults (n = 12, four nights per participant) and patients referred to a sleep examination (n = 28, one night per participant). We developed models for sleep/wake classification based on principles commonly used by actigraphy, including real-time models, and tested them on both datasets. We estimated a set of commonly reported sleep parameters from these data, including total-sleep-time, sleep-onset-latency, sleep-efficiency, and wake-after-sleep-onset, and evaluated the inter-method reliability of these estimates. Classification results were on-par with, or exceeding, those often seen for actigraphy. For real-time models in healthy young adults, accuracies were above 92%, sensitivities above 95%, specificities above 83%, and all Cohen's kappa values were above 0.81 compared to polysomnography. For patients referred to a sleep examination, accuracies were above 81%, sensitivities about 89%, specificities above 53%, and Cohen's kappa values above 0.44. Sleep variable estimates showed no significant intermethod bias, but the limits of agreement were quite wide for the group of patients referred to a sleep examination. Our results indicate that the radar has the potential to offer the benefits of contact-free real-time monitoring of sleep, both for in-patients and for ambulatory home monitoring.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Helena: Real-time Contact-free Monitoring of Sleep Activities and Events around the Bed
    Clemente, Jose
    Valero, Maria
    Li, Fangyu
    Wang, Chengliang
    Song, WenZhan
    2020 IEEE INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING AND COMMUNICATIONS (PERCOM 2020), 2020,
  • [2] Contact-free radar recordings of body movement can reflect ultradian dynamics of sleep
    Heglum, Hanne Siri Amdahl
    Drews, Henning Johannes
    Kallestad, Havard
    Vethe, Daniel
    Langsrud, Knut
    Sand, Trond
    Engstrom, Morten
    JOURNAL OF SLEEP RESEARCH, 2022, 31 (06)
  • [3] Validation of Contact-Free Sleep Monitoring Device with Comparison to Polysomnography
    Tal, Asher
    Shinar, Zvika
    Shaki, David
    Codish, Shlomi
    Goldbart, Aviv
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2017, 13 (03): : 517 - 522
  • [4] Screening for obstructive sleep apnea using a contact-free system compared with polysomnography
    Zhao, Rui
    Xue, JianBo
    Dong, Xiao Song
    Zhi, Hui
    Chen, JiaNan
    Zhao, Long
    Zhang, XueLi
    Li, Jing
    Penzel, Thomas
    Han, Fang
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2021, 17 (05): : 1075 - 1082
  • [5] Smartphone as Unobtrusive Sensor for Real-time Sleep Recognition
    Montanini, Laura
    Sabino, Nicola
    Spinsante, Susanna
    Gambi, Ennio
    2018 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), 2018,
  • [6] Contact-Free Detection of Obstructive Sleep Apnea Based on Wavelet Information Entropy Spectrum Using Bio-Radar
    Qi, Fugui
    Li, Chuantao
    Wang, Shuaijie
    Zhang, Hua
    Wang, Jianqi
    Lu, Guohua
    ENTROPY, 2016, 18 (08):
  • [7] A Real-Time Contact-Free Atrial Fibrillation Detection System for Mobile Devices
    Tseng, Chih-Wei
    Wu, Bing-Fei
    Sun, Yu
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2025, 29 (01) : 17 - 29
  • [8] Sleep/wake measurement using a non-contact biomotion sensor
    de Chazal, Philip
    Fox, Niall
    O'Hare, Emer
    Heneghan, Conor
    Zaffaroni, Alberto
    Boyle, Patricia
    Smith, Stephanie
    O'Connell, Caroline
    McNicholas, Walter T.
    JOURNAL OF SLEEP RESEARCH, 2011, 20 (02) : 356 - 366
  • [9] Real-Time Sensor- and Camera-based Logging of Sleep Postures
    Nuksawn, Lerit
    Nantajeewarawat, Ekawit
    Thiemjarus, Surapa
    2015 INTERNATIONAL COMPUTER SCIENCE AND ENGINEERING CONFERENCE (ICSEC), 2015, : 136 - 141
  • [10] Sleep Minder: An Innovative Contact-Free Device for the Estimation of the Apnoea-Hypopnoea Index
    Zaffaroni, Alberto
    de Chazal, Philip
    Heneghan, Conor
    Boyle, Patricia
    Ronayne, Patricia
    McNicholas, Walter T.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 7091 - +