The role of post-operative radiographs in predicting risk of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures - A case control study

被引:20
作者
Selvan, D. R. [1 ]
Perry, D. [1 ]
Machin, D. G. [1 ]
Brown, D. J. [1 ]
机构
[1] Royal Liverpool Univ Hosp, Liverpool L7 8XP, Merseyside, England
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2014年 / 45卷 / 12期
关键词
Distal radius; Fracture; Flexor pollicis longus; Tendon; Rupture; Volar plating; COMPLICATIONS; SYSTEM;
D O I
10.1016/j.injury.2014.05.035
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background and aim: Volar plating of distal radius fractures is one of the common procedures performed in trauma surgery. Flexor pollicis longus (FPL) rupture has been described as complication following volar plating of distal radius fractures. The aim of our study was to investigate the possible relation between parameters measured on postoperative radiographs and the occurrence of FPL ruptures. Materials and methods: This was a case control study. The post-operative radiographs of 11 FPL rupture, and 22 non-FPL rupture patients were reviewed with respect to fracture reduction and plate position and the various parameters were calculated by five independent people. Logistic regression was used to examine the importance of the variables. Results: We identified two significant factors to predict FPL rupture after volar plating of distal radial fractures. These were radial tilt and plate distance from the joint line. The odds ratio of ruptures was 0.74 (95% CI 0.57-0.95) for every degree of radial tilt <25 degrees and 0.50 (95% CI 0.28-0.88) for every millimetre that the distal end of the plate was away from the volar lip of the distal radius at the wrist joint. Conclusion: Post-operative radiographs could help us predict FPL rupture after distal radius volar plating. The findings also highlight the need for good fracture reduction and thoughtful placement of the volar plate intraoperatively to minimise the risk of FPL tendon rupture. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1885 / 1888
页数:4
相关论文
共 15 条
[1]  
Adham Mehdi N, 2009, Hand (N Y), V4, P406, DOI 10.1007/s11552-009-9180-0
[2]   Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures [J].
Al-Rashid, M. ;
Theivendran, K. ;
Craigen, M. A. C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (12) :1610-1612
[3]   Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius [J].
Bell, JSP ;
Wollstein, R ;
Citron, ND .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :225-226
[4]   FLEXOR POLLICIS LONGUS TENDON RUPTURES AFTER PALMAR PLATE FIXATION OF FRACTURES OF THE DISTAL RADIUS [J].
Casaletto, J. A. ;
Machin, D. ;
Leung, R. ;
Brown, D. J. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (04) :471-474
[5]   COMPLICATIONS OF COLLES FRACTURES [J].
COONEY, WP ;
DOBYNS, JH ;
LINSCHEID, RL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (04) :613-619
[6]   Flexor tendon injuries following locked volar plating of distal radius fractures [J].
Cross, Andrew W. ;
Schmidt, Christopher C. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (02) :164-167
[7]   Osteosynthesis of distal radial fractures with a volar locking screw plate system [J].
Drobetz, H ;
Kutscha-Lissberg, E .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) :1-6
[8]  
Duncan Scott F M, 2007, Am J Orthop (Belle Mead NJ), V36, P669
[9]   Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius:: A brief report [J].
Kambouroglou, GK ;
Axelrod, TS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (04) :737-741
[10]   Volar Plate Position and Flexor Tendon Rupture Following Distal Radius Fracture Fixation [J].
Kitay, Alison ;
Swanstrom, Morgan ;
Schreiber, Joseph J. ;
Carlson, Michelle G. ;
Nguyen, Joseph T. ;
Weiland, Andrew J. ;
Daluiski, Aaron .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (06) :1091-1096