Randomised, controlled trial of nasal continuous positive airway pressure in the extubation of infants weighing 600 to 1250 g

被引:31
作者
Davis, P
Jankov, R
Doyle, L
Henschke, P
机构
[1] Royal Hosp Women, Dept Paediat, Melbourne, Vic, Australia
[2] Univ Melbourne, Parkville, Vic 3052, Australia
来源
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION | 1998年 / 79卷 / 01期
关键词
ventilation; nasal continuous positive airway pressure; extubation;
D O I
10.1136/fn.79.1.F54
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Aim-To determine whether extubation to nasal continuous airway pressure (NCPAP) results in a greater proportion of infants remaining free of additional ventilatory support for one week after extubation compared with those extubated directly to headbox oxygen. Methods-A randomised, controlled, clinical trial was conducted at the neonatal intensive care unit of the Royal Women's Hospital, Melbourne, of infants with birthweights between 600 and 1250 g, ventilated via an endotracheal tube for more than 12 hours, requiring less than 50% oxygen, a ventilator rate less than or equal to 20/minute, considered by the clinical management team to be ready for extubation. Infants were randomly allocated either to NCPAP or to oxygen administered via a headbox. Success was defined by no requirement for additional ventilatory support over the week following extubation. Failure criteria were (i) apnoea; (ii) absolute increase in oxygen requirement greater than 15% above that required before extubation; or (iii) respiratory acidosis (pH<7.25 with pCO(2) >6.67 kPa). Results-Thirty one of 47 (66%) infants were successfully extubated to NCPAP compared with 18 of 45 (40%) for headbox oxygen. The increase in failure rate in the headbox group was due primarily to increased oxygen requirements in this group. Of the 27 who failed headbox oxygen, 26 were given a trial of NCPAP and 13 did not require endotracheal reintubation. There was no significant difference between the groups in the total number of days of assisted ventilation or the duration of inpatient stay. Conclusions-NCPAP applied prophylactically after endotracheal extubation reduces the incidence of adverse clinical events that lead to failure of extubation in the seven days after extubation. This reduction is clinically important. The benefits of NCPAP do not seem to be associated with an increased incidence of unwanted side effects.
引用
收藏
页码:F54 / F57
页数:4
相关论文
共 15 条
[1]   EFFECTS ON RESPIRATION OF CPAP IMMEDIATELY AFTER EXTUBATION IN THE VERY PRETERM INFANT [J].
ANDREASSON, B ;
LINDROTH, M ;
SVENNINGSEN, NW ;
JONSON, B .
PEDIATRIC PULMONOLOGY, 1988, 4 (04) :213-218
[2]   RANDOMIZED, CONTROLLED TRIAL OF NASOPHARYNGEAL CONTINUOUS POSITIVE AIRWAY PRESSURE IN THE EXTUBATION OF VERY-LOW-BIRTH-WEIGHT INFANTS [J].
ANNIBALE, DJ ;
HULSEY, TC ;
ENGSTROM, PC ;
WALLIN, LA ;
OHNING, BL .
JOURNAL OF PEDIATRICS, 1994, 124 (03) :455-460
[3]  
Bancalari Eduardo, 1992, P200
[4]   RANDOMIZED TRIAL OF METHODS OF EXTUBATION IN ACUTE AND CHRONIC RESPIRATORY-DISTRESS [J].
CHAN, V ;
GREENOUGH, A .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1993, 68 (05) :570-572
[5]   POST-EXTUBATION NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE - A PROSPECTIVE CONTROLLED-STUDY [J].
ENGELKE, SC ;
ROLOFF, DW ;
KUHNS, LR .
AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1982, 136 (04) :359-361
[6]   CONTINUOUS POSITIVE AIRWAY PRESSURE VIA A SINGLE NASAL CATHETER IN PRETERM INFANTS [J].
FIELD, D ;
VYAS, H ;
MILNER, AD ;
HOPKIN, IE .
EARLY HUMAN DEVELOPMENT, 1985, 11 (3-4) :275-280
[7]  
GARNER A, 1984, PEDIATRICS, V74, P127
[8]   TREATMENT OF IDIOPATHIC RESPIRATORY-DISTRESS SYNDROME WITH CONTINUOUS POSITIVE AIRWAY PRESSURE [J].
GREGORY, GA ;
KITTERMAN, JA ;
PHIBBS, RH ;
TOOLEY, WH ;
HAMILTON, WK .
NEW ENGLAND JOURNAL OF MEDICINE, 1971, 284 (24) :1333-+
[9]  
HIGGINS RD, 1991, PEDIATRICS, V88, P999
[10]  
KORONES SB, 1988, ASSISTED VENTILATION, P245