Critical temperature of free cooling using indirect opening cooling tower in data centres: a review

被引:6
|
作者
Liu, Jing [1 ,2 ,3 ,4 ]
Su, Lin [1 ,3 ,4 ]
Dong, Kaijun [1 ,3 ,4 ]
Liu, Xueliang [5 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou, Guangdong, Peoples R China
[2] Univ Chinese Acad Sci, Beijing, Guangdong, Peoples R China
[3] CAS Key Lab Renewable Energy, Guangzhou, Guangdong, Peoples R China
[4] Guangdong Prov Key Lab New & Renewable Energy Res, Guangzhou, Guangdong, Peoples R China
[5] Univ Southern Calif, Dept Elect & Comp Engn, Los Angeles, CA 90007 USA
关键词
Data centres; free cooling; critical temperature; cooling approach;
D O I
10.1080/01430750.2019.1694069
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The energy consumption of data centres is increasing rapidly. The key to energy saving in the data centre is to reduce cooling energy consumption, resulting from 30-50% of the total power consumption in the data centre. The free cooling of the cooling tower is a significant method to reduce cooling energy consumption. Determining a reasonable critical temperature of free cooling can extend the free cooling time, which is significant for energy saving. In this study, an overview of the current status and affecting factors of the critical temperature had discussed. Chilled water supply temperature and cooling approach are the key factors of critical temperature and are analysed. Further, this review proposes an effective method to obtain the critical temperature of free cooling.
引用
收藏
页码:1339 / 1344
页数:6
相关论文
共 50 条
  • [1] Free cooling of data centers: A review
    Zhang, Hainan
    Shao, Shuangquan
    Xu, Hongbo
    Zou, Huiming
    Tian, Changqing
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 35 : 171 - 182
  • [2] Cooling technologies for data centres and telecommunication base stations-A comprehensive review
    Zhang, Yelong
    Zhao, Yanqi
    Dai, Siyuan
    Nie, Binjian
    Ma, Hongkun
    Li, Jianming
    Miao, Qi
    Jin, Yi
    Tan, Linghua
    Ding, Yulong
    JOURNAL OF CLEANER PRODUCTION, 2022, 334
  • [3] Critical review of latent heat storage systems for free cooling in buildings
    Zeinelabdein, Rami
    Omer, Siddig
    Gan, Guohui
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 82 : 2843 - 2868
  • [4] Experimental investigation of an optimized indirect free cooling system including a dry cooler equipped with evaporative cooling pads for data center
    Hnayno, Mohamad
    Chehade, Ali
    Klaba, Henryk
    Polidori, Guillaume
    Maalouf, Chadi
    ENERGY REPORTS, 2023, 9 : 460 - 469
  • [5] Experimental investigation of an optimized indirect free cooling system including a dry cooler equipped with evaporative cooling pads for data center
    Hnayno, Mohamad
    Chehade, Ali
    Klaba, Henryk
    Polidori, Guillaume
    Maalouf, Chadi
    ENERGY REPORTS, 2023, 9 : 460 - 469
  • [6] Experimental study on direct evaporative cooling for free cooling of data centers
    Li, Chao
    Mao, Ruiyong
    Wang, Yong
    Zhang, Jun
    Lan, Jiang
    Zhang, Zujing
    ENERGY, 2024, 288
  • [7] Review on free cooling of buildings using phase change materials
    Raj, V. Antony Aroul
    Velraj, R.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2010, 14 (09): : 2819 - 2829
  • [8] Cooling performance of a pump-driven two phase cooling system for free cooling in data centers
    Ma, Yuezheng
    Ma, Guoyuan
    Zhang, Shuang
    Zhou, Feng
    APPLIED THERMAL ENGINEERING, 2016, 95 : 143 - 149
  • [9] Investigation on the Energy Saving Potential of Using a Novel Dew Point Cooling System in Data Centres
    Bi, Yin
    Wang, Yugang
    Ma, Xiaoli
    Zhao, Xudong
    ENERGIES, 2017, 10 (11):
  • [10] Relating measured PUE to the cooling strategy and operating conditions through a review of a number of Maltese data centres
    Abdilla, Amy
    Borg, Simon P.
    Licari, John