Off-pump insertion of continuous flow left ventricular assist devices

被引:30
作者
Selzman, Craig H. [1 ]
Sheridan, Brett C. [1 ]
机构
[1] Univ N Carolina, Div Cardiothorac Surg, Chapel Hill, NC 27599 USA
关键词
D O I
10.1111/j.1540-8191.2007.00429.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Aim of the Study. Traditional left ventricular assist device (LVAD) implantation requires extensive dissection and use of cardiopulmonary bypass (CPB). Potential adverse effects of CPB in very ill end-stage heart failure patients include right ventricular dysfunction, end-organ injury, and bleeding. We sought to evaluate the feasibility and outcome of LVAD insertion without CPB. Methods: The Jarvik 2000 is an axial-flow pump newly involved in a phase I clinical trial in status I patients as a bridge to transplantation. Seven patients received this pump through thoracotomy or sternotomy with or without the use of CPB. Results: All patients had NYHA class IV heart failure with end-organ dysfunction requiring inotropic therapy. Two were in cardiogenic shock, necessitating full CPB support. Five patients had the Jarvik implanted off-CPB. The off-CPB patients were associated with decreased length of surgery, mechanical ventilation, blood transfusions, inotropic support, and hospital stay including rehabilitation. Nearly all of the patients had complete resolution of liver and kidney dysfunction. Conclusion: We have demonstrated that off-CPB insertion of axial flow LVADs is feasible, safe, and potentially advantageous. Although we are encouraged by the perioperative simplicity of this strategy, we acknowledge that additional implants and comparisons of outcomes with traditional pulsatile and continuous flow device techniques will be necessary to advocate its widespread adoption.
引用
收藏
页码:320 / 322
页数:3
相关论文
共 11 条
  • [1] Lung injury and acute respiratory distress syndrome after cardiopulmonary bypass
    Asimakopoulos, G
    Smith, PLC
    Ratnatunga, CP
    Taylor, KM
    [J]. ANNALS OF THORACIC SURGERY, 1999, 68 (03) : 1107 - 1115
  • [2] Mechanical circulatory support device database of the International Society for Heart and Lung Transplantation: Third Annual Report - 2005
    Deng, MC
    Edwards, LB
    Hertz, MI
    Rowe, AW
    Keck, BM
    Kormos, R
    Naftel, DC
    Kirklin, JK
    Taylor, DO
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (09) : 1182 - 1187
  • [3] Initial experience with non-thoracic, extraperitoneal, off-pump insertion of the Jarvik 2000 Heart in patients with previous median sternotomy
    Frazier, O. H.
    Gregoric, Igor D.
    Cohn, William E.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (05) : 499 - 503
  • [4] Implantation of the Jarvik 2000 left ventricular assist device without the use of cardiopulmonary bypass
    Frazier, OH
    [J]. ANNALS OF THORACIC SURGERY, 2003, 75 (03) : 1028 - 1030
  • [5] Aortic valve bypass for the high-risk patient with aortic stenosis
    Gammie, JS
    Brown, JW
    Brown, JM
    Poston, RS
    Pierson, RN
    Odonkor, PN
    White, CS
    Gottdiener, JS
    Griffith, BP
    [J]. ANNALS OF THORACIC SURGERY, 2006, 81 (05) : 1605 - 1611
  • [6] HeartMate vented-electric left ventricular assist system: Technique for intrathoracic or intraperitoneal implantation via a left thoracotomy
    Gregoric, I
    Wadia, Y
    Radovancevic, B
    Messner, G
    Khan, T
    Frazier, OH
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2004, 23 (06) : 759 - 762
  • [7] Inflammatory response to cardiopulmonary bypass
    Levy, JH
    Tanaka, KA
    [J]. ANNALS OF THORACIC SURGERY, 2003, 75 (02) : S715 - S720
  • [8] Long James W, 2005, Congest Heart Fail, V11, P133, DOI 10.1111/j.1527-5299.2005.04540.x
  • [9] Predictors of severe right ventricular failure after Implantable left ventricular assist device insertion: Analysis of 245 patients
    Ochiai, Y
    McCarthy, PM
    Smedira, NG
    Banbury, MK
    Navia, JL
    Feng, JY
    Hsu, AP
    Yeager, ML
    Buda, T
    Hoercher, KJ
    Howard, MW
    Takagaki, M
    Doi, K
    Fukamachi, K
    [J]. CIRCULATION, 2002, 106 (13) : I198 - I202
  • [10] Improved mechanical reliability of the HeartMate XVE left ventricular assist system
    Pagani, Francis D.
    Long, James W.
    Dembitsky, Walter P.
    Joyce, Lyle D.
    Miller, Leslie W.
    [J]. ANNALS OF THORACIC SURGERY, 2006, 82 (04) : 1413 - 1419