A novel in vitro flow system for changing flow direction on endothelial cells

被引:42
|
作者
Wang, Chong [1 ]
Lu, Hao [2 ]
Schwartz, Martin Alexander [1 ,3 ,4 ,5 ]
机构
[1] Univ Virginia, Robert M Berne Cardiovasc Res Ctr, Charlottesville, VA 22908 USA
[2] Univ Minnesota Twin Cities, St Anthony Falls Lab, Minneapolis, MN USA
[3] Univ Virginia, Dept Microbiol, Charlottesville, VA 22908 USA
[4] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22908 USA
[5] Univ Virginia, Dept Cell Biol, Charlottesville, VA 22908 USA
关键词
Parallel plate device; Shear stress; Endothelial cells; Mechanotransduction; Cell alignment; WALL SHEAR-STRESS; DISTURBED FLOW; PULSATILE FLOW; BLOOD-FLOW; ATHEROSCLEROSIS; PATTERNS; BIFURCATION; DISTAL; AORTA;
D O I
10.1016/j.jbiomech.2012.01.045
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Atherosclerotic plaques localize to regions of flow disturbance, i.e. bifurcations, branch points and regions of high curvature. Shear stress in these regions can be multi-directional due to complex flow patterns such as time-varying vortices. However, commonly used in vitro flow models are incapable of changing flow orientation to any direction other than the reverse. We have developed a novel in vitro flow system to enable changes in flow direction to any angle. When cells were pre-aligned in laminar shear, and then rotated 90 degrees, cells re-aligned over 24 h. Re-alignment involved actin remodeling by gradual rotation of actin stress fibers. This device will enable that analysis of how endothelial cells sense changes in flow direction as occur in vivo. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1212 / 1218
页数:7
相关论文
共 50 条
  • [41] Fluid flow regulates translation in endothelial cells
    Kraiss, LW
    Weyrich, AS
    McIntyre, TM
    Zimmerman, GA
    JOURNAL OF VASCULAR SURGERY, 2001, 33 (06) : 1298 - 1299
  • [42] Ultrastructure of endothelial cells under flow alteration
    Masuda, H
    Kawamura, K
    Nanjo, H
    Sho, E
    Komatsu, M
    Sugiyama, T
    Sugita, A
    Asari, Y
    Kobayashi, M
    Ebina, T
    Hoshi, N
    Singh, TM
    Xu, CP
    Zarins, CK
    MICROSCOPY RESEARCH AND TECHNIQUE, 2003, 60 (01) : 2 - 12
  • [43] Erratum to: Effects of Disturbed Flow on Endothelial Cells
    Shu Chien
    Annals of Biomedical Engineering, 2010, 38 (3) : 1258 - 1258
  • [44] Adhesion behavior of endothelial progenitor cells to endothelial cells in simple shear flow
    Xiao-Bo Gong · Yu-Qing Li · Quan-Chao Gao · Bin-Bin Cheng · Bao-Rong Shen · Zhi-Qiang Yan · Zong-Lai Jiang Institute of Mechanobiology and Biomedical Engineering
    Acta Mechanica Sinica, 2011, (06) : 1071 - 1080
  • [45] Adhesion behavior of endothelial progenitor cells to endothelial cells in simple shear flow
    Gong, Xiao-Bo
    Li, Yu-Qing
    Gao, Quan-Chao
    Cheng, Bin-Bin
    Shen, Bao-Rong
    Yan, Zhi-Qiang
    Jiang, Zong-Lai
    ACTA MECHANICA SINICA, 2011, 27 (06) : 1071 - 1080
  • [46] Adhesion behavior of endothelial progenitor cells to endothelial cells in simple shear flow
    Xiao-Bo Gong
    Yu-Qing Li
    Quan-Chao Gao
    Bin-Bin Cheng
    Bao-Rong Shen
    Zhi-Qiang Yan
    Zong-Lai Jiang
    Acta Mechanica Sinica, 2011, 27 : 1071 - 1080
  • [47] Adhesion behavior of endothelial progenitor cells to endothelial cells in simple shear flow
    XiaoBo Gong YuQing Li QuanChao Gao BinBin Cheng BaoRong Shen ZhiQiang Yan ZongLai Jiang Institute of Mechanobiology and Biomedical EngineeringSchool of Life Sciences and BiotechnologyShanghai Jiao Tong University ShanghaiChina Department of Engineering MechanicsSchool of Naval ArchitectureOcean and Civil EngineeringShanghai Jiao Tong University ShanghaiChina
    Acta Mechanica Sinica, 2011, 27 (06) : 1071 - 1080
  • [48] Molecular Sensors of Blood Flow in Endothelial Cells
    Baratchi, Sara
    Khoshmanesh, Khashayar
    Woodman, Owen L.
    Potocnik, Simon
    Peter, Karlheinz
    McIntyre, Peter
    TRENDS IN MOLECULAR MEDICINE, 2017, 23 (09) : 850 - 868
  • [49] Response of vascular endothelial cells to fluid flow
    Fujiwara, K
    Masuda, M
    Osawa, M
    Katoh, K
    Kano, Y
    Harada, N
    Lopes, RB
    BIOLOGICAL BULLETIN, 1998, 194 (03): : 384 - 385
  • [50] APPLICATION OF AN IN-VITRO MODEL OF FLOW SENSING TO PULMONARY-ARTERY ENDOTHELIAL-CELLS
    ROLLER, JA
    FOUTY, B
    WALCHAK, S
    RODMAN, DM
    CLINICAL RESEARCH, 1994, 42 (01): : A58 - A58