A novel in vitro flow system for changing flow direction on endothelial cells

被引:42
|
作者
Wang, Chong [1 ]
Lu, Hao [2 ]
Schwartz, Martin Alexander [1 ,3 ,4 ,5 ]
机构
[1] Univ Virginia, Robert M Berne Cardiovasc Res Ctr, Charlottesville, VA 22908 USA
[2] Univ Minnesota Twin Cities, St Anthony Falls Lab, Minneapolis, MN USA
[3] Univ Virginia, Dept Microbiol, Charlottesville, VA 22908 USA
[4] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22908 USA
[5] Univ Virginia, Dept Cell Biol, Charlottesville, VA 22908 USA
关键词
Parallel plate device; Shear stress; Endothelial cells; Mechanotransduction; Cell alignment; WALL SHEAR-STRESS; DISTURBED FLOW; PULSATILE FLOW; BLOOD-FLOW; ATHEROSCLEROSIS; PATTERNS; BIFURCATION; DISTAL; AORTA;
D O I
10.1016/j.jbiomech.2012.01.045
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Atherosclerotic plaques localize to regions of flow disturbance, i.e. bifurcations, branch points and regions of high curvature. Shear stress in these regions can be multi-directional due to complex flow patterns such as time-varying vortices. However, commonly used in vitro flow models are incapable of changing flow orientation to any direction other than the reverse. We have developed a novel in vitro flow system to enable changes in flow direction to any angle. When cells were pre-aligned in laminar shear, and then rotated 90 degrees, cells re-aligned over 24 h. Re-alignment involved actin remodeling by gradual rotation of actin stress fibers. This device will enable that analysis of how endothelial cells sense changes in flow direction as occur in vivo. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1212 / 1218
页数:7
相关论文
共 50 条
  • [1] Alignment of endothelial cells in the direction of flow in porcine coronary arteries
    LaMack, JA
    Himburg, HA
    Friedman, MH
    FASEB JOURNAL, 2006, 20 (04): : A652 - A652
  • [2] Endothelial Cell Sensing of Flow Direction
    Wang, Chong
    Baker, Brendon M.
    Chen, Christopher S.
    Schwartz, Martin Alexander
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2013, 33 (09) : 2130 - 2136
  • [3] An In Vitro Hemodynamic Flow System to Study the Effects of Quantified Shear Stresses on Endothelial Cells
    Hamed Avari
    Eric Savory
    Kem A. Rogers
    Cardiovascular Engineering and Technology, 2016, 7 : 44 - 57
  • [4] An In Vitro Hemodynamic Flow System to Study the Effects of Quantified Shear Stresses on Endothelial Cells
    Avari, Hamed
    Savory, Eric
    Rogers, Kem A.
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2016, 7 (01) : 44 - 57
  • [5] An In Vitro Perfusion System to Examine the Responses of Endothelial Cells to Simulated Flow and Inflammatory Stimulation
    Cockcroft, Natalia Y.
    Oke, Oluwatobiloba
    Cunningham, Fiona
    Bishop, Emma
    Fearon, Ian M.
    Zantl, Roman
    Gaca, Marianna D.
    ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2009, 37 (06): : 657 - 669
  • [6] Application of a 45° bend pipe with a bypass flow meter without changing the flow direction or the system construction
    Trung, M. C.
    Nishiyama, S.
    Anyoji, H.
    TRANSACTIONS OF THE ASABE, 2007, 50 (06) : 2051 - 2057
  • [7] Flow-induced regulation of brain endothelial cells in vitro
    Mao, XiaOu
    Xie, Lin
    Greenberg, Rose B.
    Greenberg, Jack B.
    Peng, Botao
    Mieling, Isabelle
    Jin, Kunlin
    Greenberg, David A.
    VASCULAR PHARMACOLOGY, 2014, 62 (02) : 82 - 87
  • [8] Effect of flow direction on the morphological responses of cultured bovine aortic endothelial cells
    N. Kataoka
    S. Ujita
    M. Sato
    Medical and Biological Engineering and Computing, 1998, 36 : 122 - 128
  • [9] Effect of flow direction on the morphological responses of cultured bovine aortic endothelial cells
    Kataoka, N
    Ujita, S
    Sato, M
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (01) : 122 - 128