Assessment of the reliability of endothelial cell-density estimates in the presence of pseudoguttata

被引:4
作者
Doughty, Michael J. [1 ]
Jonuscheit, Sven [1 ]
Button, Norman F. [1 ]
机构
[1] Glasgow Caledonian Univ, Dept Vis Sci, Glasgow G4 OBA, Lanark, Scotland
关键词
Specular microscopy; Human; Corneal endothelium; Pseudoguttata; Morphometry; SPECULAR MICROSCOPY; CORNEA GUTTATA; ANTERIOR UVEITIS; DYSTROPHY;
D O I
10.1007/s00417-011-1812-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of this work is to assess the reliability of endothelial cell-density (ECD) estimates in corneas with different severity pseudoguttata. Specular microscopy was undertaken on grade 1, 2, or 3 pseudoguttata patients and age-matched controls aged 52-83 years. On high magnification prints of central cornea, areas of complete cells (all sides visible) and partial 'cells' (one or more sides obscured) were measured manually. Sets of 45 complete cells were selected, as well as 75 cells that were a mixture of complete and partial cells on guttate endothelia. ECD was calculated by a progressive averaging technique. Each group comprised 12 patients with similar range of ECD values (1,230-4,587 cells/mm(2)). Based on 40 complete cells, ECD could be estimated to within +/- 3.1% for grade 3 pseudoguttata versus +/- 2.0% for controls. If a mixture of complete and partial cells were measured, ECD could be estimated to within +/- 2.8% for grade 3 pseudoguttata images (n = 70 cells) and +/- 1.1% for controls. The estimated variability increases to substantial levels of +/- 20% if only ten cells were measured. No statistical differences in ECD were noted between guttate and normal endothelia if only complete cells were measured, but could be different if partial 'cells' were included. Providing adequate numbers of complete cells are measured and in the absence of obvious polymegathism, ECD estimates can be made to within around +/- 3% in the presence of typical but significant pseudoguttata.
引用
收藏
页码:111 / 121
页数:11
相关论文
共 32 条
  • [1] ALANKO HI, 1986, ACTA OPHTHALMOL, V64, P623
  • [2] Specular microscopy ancillary study methods for donor endothelial cell density determination of cornea donor study images
    Benetz, BA
    Gal, RL
    Ruedy, KJ
    Rice, C
    Beck, RW
    Kalajian, AD
    Lass, JH
    [J]. CURRENT EYE RESEARCH, 2006, 31 (04) : 319 - 327
  • [3] CORNEA GUTTATA IN SPECULAR MICROSCOPY
    BIGAR, F
    HURZELER, R
    REJMAN, P
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1980, 176 (04) : 644 - 647
  • [4] A COMPARISON OF CORNEAL ENDOTHELIAL MORPHOLOGY IN CORNEA GUTTATA, FUCHS DYSTROPHY AND BULLOUS KERATOPATHY
    BROOKS, AMV
    GRANT, G
    GILLIES, WE
    [J]. AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1988, 16 (02): : 93 - 100
  • [5] BURNS RR, 1981, INVEST OPHTH VIS SCI, V20, P77
  • [6] Corneal specular microscopy in infectious and noninfectious uveitis
    de Oliveira, Filipe
    de Oliveira Motta, Ana Carolina
    Muccioli, Cristina
    [J]. ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (04) : 457 - 461
  • [7] Deb-Joardar N, 2006, INVEST OPHTH VIS SCI, V47, P4343
  • [8] Dong Wei-Li, 2004, Zhonghua Yan Ke Za Zhi, V40, P465
  • [9] ASSESSMENT OF THE RELIABILITY OF CALCULATIONS OF THE COEFFICIENT OF VARIATION FOR NORMAL AND POLYMEGETHOUS HUMAN CORNEAL ENDOTHELIUM
    DOUGHTY, MJ
    FONN, D
    NGUYEN, KT
    [J]. OPTOMETRY AND VISION SCIENCE, 1993, 70 (09) : 759 - 770
  • [10] Assessment of the reliability of human corneal endothelial cell-density estimates using a noncontact specular microscope
    Doughty, MJ
    Müller, A
    Zaman, ML
    [J]. CORNEA, 2000, 19 (02) : 148 - 158