Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method

被引:100
作者
Chen, Huiping [1 ]
McCoy, Leslie F. [1 ,2 ]
Schleicher, Rosemary L. [1 ]
Pfeiffer, Christine M. [1 ]
机构
[1] Ctr Dis Control & Prevent, Atlanta, GA USA
[2] Battelle Mem Inst, Atlanta, GA USA
关键词
25-hydroxyvitamin D; HPLC; LC-MS/MS; radioimmunoassay; RIA; method comparison;
D O I
10.1016/j.cca.2008.01.017
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Measurement of vitamin D molecules are important in the management of patients with bone disease. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to measure 25OHD(3) and 25OHD(2) in human serum and compared it to the traditionally used DiaSorin radioimmunoassay (RIA). Methods: Serum samples (200 mu l) were treated with acetonitrile and centrifuged to remove protein. An online solid-phase extraction procedure was used. Calibration solutions (5-100 ng/ml) of 25OHD(2) and 25OHD(3) were prepared using 4% albumin in phosphate-buffered saline. Chromatography: C 18 column, isocratic ethanol/water (83/17, v/v). Mass spectrometry system: atmospheric pressure chemical ionization in the positive ion mode. Transitions: 250HD3, m/z 401.4 -> 383.4; 25OHD(2), m/z 413.4 -> 395.4; and the internal standard hexadeuterated-25OHD(3), m/z 407.7 -> 389.7. Results: Detection limits were 0.49 ng/ml (25OHD(3)) and 1.86 ng/ml (25OHD(2)). Intra- and inter-assay coefficients of variation (CV) were <7% and <11%, respectively, for 250HD3 and <9% and <16%, respectively, for 25OHD(2). Recovery averaged (SD) 99% (2%) for 25OHD(3) and 95% (0.8%) for 25OHD(2). In a method comparison of 551 specimens from the National Health and Nutrition Examination Survey, the LC-MS/MS method gave values that were on average 13% higher (95%CI: 11-15%) than RIA results. Conclusions: This high throughput candidate reference method requires minimal sample preparation and is suitable for routine use for analysis of vitamin D status. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:6 / 12
页数:7
相关论文
共 20 条
  • [1] Antoniucci DM, 2005, CLIN CHEM, V51, P258
  • [2] Vitamin D2 is much less effective than vitamin D3 in humans
    Armas, LAG
    Hollis, BW
    Heaney, RP
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2004, 89 (11) : 5387 - 5391
  • [3] The anomalous behaviour of exogenous 25-hydroxyvitamin D in competitive binding assays
    Carter, G. D.
    Jones, J. C.
    Berry, J. L.
    [J]. JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2007, 103 (3-5) : 480 - 482
  • [4] Prospective study of serum vitamin D and cancer mortality in the United States
    Freedman, D. Michal
    Looker, Anne C.
    Chang, Shih-Chen
    Graubard, Barry I.
    [J]. JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2007, 99 (21): : 1594 - 1602
  • [5] Vitamin D and prevention of breast cancer: Pooled analysis
    Garland, Cedric F.
    Gorham, Edward D.
    Mohr, Sharif B.
    Grant, William B.
    Giovannucci, Edward L.
    Lipkin, Martin
    Newmark, Harold
    Holick, Michael F.
    Garland, Frank C.
    [J]. JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2007, 103 (3-5) : 708 - 711
  • [6] Optimal vitamin D status for colorectal cancer prevention - A quantitative meta analysis
    Gorham, Edward D.
    Garland, Cedric F.
    Garland, Frank C.
    Grant, William B.
    Mohr, Sharif B.
    Lipkin, Martin
    Newmark, Harold L.
    Giovannucci, Edward
    Wei, Melissa
    Holick, Michael F.
    [J]. AMERICAN JOURNAL OF PREVENTIVE MEDICINE, 2007, 32 (03) : 210 - 216
  • [7] The vitamin D epidemic and its health consequences
    Holick, MF
    [J]. JOURNAL OF NUTRITION, 2005, 135 (11) : 2739S - 2748S
  • [8] Holick MF, 2004, AM J CLIN NUTR, V79, P362
  • [9] Vitamin D deficiency
    Holick, Michael F.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (03) : 266 - 281
  • [10] HOLLIS BW, 1993, CLIN CHEM, V39, P529