An In Vitro Biomechanical Comparison of Single-Rod, Dual-Rod, and Dual-Rod With Transverse Connector in Anterior Thoracolumbar Instrumentation

被引:9
|
作者
Reddy, Chandan G. [1 ]
Magnetta, Michael [2 ]
Dahdaleh, Nader S. [1 ]
Demmer, Matthew [2 ]
Iyamah, Kingsley Abode [1 ]
Lim, Tae-Hong [2 ]
Torner, James C. [3 ]
Hitchon, Patrick W. [1 ]
机构
[1] Univ Iowa, Dept Neurosurg, Iowa City, IA USA
[2] Univ Iowa, Dept Biomed Engn, Iowa City, IA USA
[3] Univ Iowa, Dept Epidemiol, Iowa City, IA USA
关键词
Anterior fixation; Biomechanics; Corpectomy; Thoracolumbar spine; BURST FRACTURES; LUMBAR SPINE; CADAVERIC SPINE; PEDICLE SCREW; POSTERIOR; DECOMPRESSION; FUSION; STABILIZATION; SCOLIOSIS; FIXATION;
D O I
10.1227/NEU.0b013e31823cf254
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: After thoracolumbar corpectomy, standard anterolateral instrumentation may consist of dual rods with cross-connectors. However, when the vertebral bodies are small or involved with disease, only 1 rod may be possible. OBJECTIVE: To compare the biomechanics of an in vitro L1 corpectomy model using 1 rod, 2 rods, or 2 rods with 2 cross-connectors. METHODS: Eight fresh frozen human cadaveric spines were potted from T9 to L3. Pure moments of 1.5, 3, and 4.5 Nm were applied, and the motion of the spine was measured using 3 infrared cameras. Loads were applied in flexion and extension, right and left lateral bending, and right and left axial rotation. Each spine was first tested in the intact state. After performing an L1 corpectomy and replacement with a carbon fiber reinforced polymer cage, 3 constructs were tested: single rod (1R), dual rod (2R), and dual rod with 2 transverse connectors (CC). RESULTS: Analysis of variance suggests significant main effects of load (P < .0001), axis (P = .022), construct (P = .0019), and individual spine (P < .0001). Overall, the single-rod construct is significantly less rigid than the intact spine in axial rotation. There is no significant difference between the intact spine and either the dual-rod construct or the dual-rod cross-connector construct. CONCLUSION: In our in vitro model of anterior spinal stabilization after corpectomy and grafting, a single-rod construct is significantly less rigid than the intact spine. Addition of a second rod returns the rigidity of the spine to the intact state. A dual-rod cross-connector construct is significantly more rigid than a single-rod construct.
引用
收藏
页码:1017 / 1023
页数:7
相关论文
共 50 条
  • [2] Single-rod versus dual-rod anterior instrumentation for idiopathic scoliosis -: A biomechanical study
    Lowe, TG
    Enguidanos, ST
    Smith, DAB
    Hashim, S
    Eule, JM
    O'Brien, MF
    Diekmann, MJ
    Wilson, L
    Trommeter, JM
    SPINE, 2005, 30 (03) : 311 - 317
  • [3] New rod-plate anterior instrumentation for thoracolumbar/lumbar scoliosis: Biomechanical evaluation compared with dual-rod and single-rod with structural interbody support
    Zhang, Hong
    Johnston, Charles E., II
    Pierce, William A.
    Ashman, Richard B.
    Bronson, Dwight G.
    Haideri, Nessie F.
    SPINE, 2006, 31 (25) : E934 - E940
  • [4] Novel Dual-Rod Screw for Thoracoscopic Anterior Instrumentation Biomechanical Evaluation Compared With Single-Rod and Double-Screw/Double-Rod Anterior Constructs
    Zhang, Hong
    Sucato, Daniel J.
    Pierce, William A.
    Ross, David
    SPINE, 2009, 34 (05) : E183 - E188
  • [5] Single- versus dual-rod anterior instrumentation of thoracolumbar curves in adolescent idiopathic scoliosis
    Mithun Nambiar
    Yi Yang
    Susan Liew
    Peter L. Turner
    Ian P. Torode
    European Spine Journal, 2016, 25 : 3249 - 3255
  • [6] Single- versus dual-rod anterior instrumentation of thoracolumbar curves in adolescent idiopathic scoliosis
    Nambiar, Mithun
    Yang, Yi
    Liew, Susan
    Turner, Peter L.
    Torode, Ian P.
    EUROPEAN SPINE JOURNAL, 2016, 25 (10) : 3249 - 3255
  • [7] DUAL-ROD INSTRUMENTATION VIA THE ANTERIOR APPROACH FOR THORACOLUMBAR AND LUMBAR ADOLESCENT IDIOPATHIC SCOLIOSIS
    Sudo, Hideki
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2022, 12 (04):
  • [8] Prospective radiographic and clinical outcomes of dual-rod instrumented anterior spinal fusion in adolescent idiopathic scoliosis: Comparison with single-rod constructs
    Hurford, Robert K., Jr.
    Lenke, Lawrence G.
    Lee, Stanley S.
    Cheng, Ivan
    Sides, Brenda
    Bridwell, Keith H.
    SPINE, 2006, 31 (20) : 2322 - 2328
  • [9] Range of motion after thoracolumbar corpectomy: evaluation of analogous constructs with a novel low-profile anterior dual-rod system and a traditional dual-rod system
    Gehrchen, Martin
    Hegde, Sajan K.
    Moldavsky, Mark
    Chinthukunta, Suresh
    Gudipally, Manasa
    Bucklen, Brandon
    Salloum, Kanaan
    Khalil, Saif
    EUROPEAN SPINE JOURNAL, 2017, 26 (03) : 666 - 670
  • [10] Range of motion after thoracolumbar corpectomy: evaluation of analogous constructs with a novel low-profile anterior dual-rod system and a traditional dual-rod system
    Martin Gehrchen
    Sajan K. Hegde
    Mark Moldavsky
    Suresh Chinthukunta
    Manasa Gudipally
    Brandon Bucklen
    Kanaan Salloum
    Saif Khalil
    European Spine Journal, 2017, 26 : 666 - 670