An optimally designed digital differentiator based preprocessor for R-peak detection in electrocardiogram signal

被引:29
|
作者
Nayak, Chandan [1 ]
Saha, Suman Kumar [1 ]
Kar, Rajib [2 ]
Mandal, Durbadal [2 ]
机构
[1] NIT Raipur, Dept Elect & Telecommun Engn, Raipur 492010, Chhattisgarh, India
[2] NIT Durgapur, Dept Elect & Commun Engn, Durgapur 713209, W Bengal, India
关键词
Electrocardiogram (ECG); Gravitational search algorithm; Integer order digital differentiator; Hilbert transform; QRS complex detection; QRS-DETECTION ALGORITHM; AUTOMATIC DETECTION; OPTIMIZATION ALGORITHM; COMPLEX DETECTION; FIDUCIAL POINTS; ECG; HILBERT; FILTERS;
D O I
10.1016/j.bspc.2018.09.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Globally the human death rate is accelerating day by day due to the cardiovascular diseases (CVDs), and it will be elevated shortly. In this scenario, the QRS complex detection of electrocardiogram (ECG) signal is considered as a simple, non-invasive, inexpensive, and preliminary diagnosis method used to assess the cardiac health of a patient. In this paper, an optimally designed Integer Order Digital Differentiator (IODD) based preprocessor is proposed for the accurate estimation of R-peak locations in the ECG signal. IODD, one of the major constituents of the preprocessor, is designed most proficiently by using a metaheuristic evolutionary optimization method called Gravitational Search Algorithm (GSA). In GSA, as the number of iteration increases the exploration capability fades out, and the exploitation capability fades in, which help it to avoid the local optima stagnation problem and results in faster convergence. The IODD based preprocessor accentuates the QRS complexes of the ECG signal irrespective of its abnormal morphology. The employed detector is a simple threshold independent R-peak decision logic designed by utilizing the properties of the Hilbert transform. In order to emphasize the superiority of the proposed research work the proposed IODD based QRS detection approach is validated on the first channel records of MIT/BIH Arrhythmia database (MBAD), QT database (QTDB), MIT/BIH noise stress test database (NSTDB), atrial fibrillation termination challenge database (AFTDB), and MIT/BIH ST change database (STDB). The sensitivity (Se) and positive Predictivity (+P) values for MBAD, QTDB, NSTDB, AFTDB, and STDB are Se=99.92% and +P=99.92%, Se=99.98% and +P=99.96%, Se=95.23% and +P=94.41%, Se=99.03% and +P=99.76%, and Se=99.93% and +P=99.90%, respectively. These performance metrics ensure the accuracy of the proposed R-peak detection technique for a wide variety of QRS morphologies and thereby affirm the applicability of the proposed IODD for the efficient detection of R-peak locations. The performance of the proposed R-peak detector significantly outperforms the reported methods in terms of all the performance metrics. The enhanced QRS detection accuracy of the proposed approach is due to the better feature signal generating capability of the proposed IODD. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:440 / 464
页数:25
相关论文
共 50 条
  • [41] R-PEAK DETECTION USING WAVELET TRANSFORMS TECHNIQUE
    Bensegueni, Skander
    Bennia, Abdelhak
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2015, 77 (03): : 135 - 148
  • [42] Robust ECG R-peak Detection Using LSTM
    Laitala, Juho
    Jiang, Mingzhe
    Syrjala, Elise
    Naeini, Emad Kasaeyan
    Airola, Antti
    Rahmani, Amir M.
    Dutt, Nikil D.
    Liljeberg, Pasi
    PROCEEDINGS OF THE 35TH ANNUAL ACM SYMPOSIUM ON APPLIED COMPUTING (SAC'20), 2020, : 1104 - 1111
  • [43] Variable Threshold Method for ECG R-peak Detection
    Kew, Hsein-Ping
    Jeong, Do-Un
    JOURNAL OF MEDICAL SYSTEMS, 2011, 35 (05) : 1085 - 1094
  • [44] Single-lead fetal electrocardiogram estimation by means of combining R-peak detection, resampling and comb filter
    Zheng Wei
    Liu Hongxing
    He Aijun
    Ning Xinbao
    Cheng Jianchun
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (07) : 708 - 719
  • [45] R-Peak Detection in ECG Signal Using Yule-Walker and Principal Component Analysis
    Gupta, Varun
    Mittal, Monika
    IETE JOURNAL OF RESEARCH, 2021, 67 (06) : 921 - 934
  • [46] Adaptive Fourier Decomposition Based R-peak Detection for Noisy ECG Signals
    Wang, Ze
    Wong, Chi Man
    Wan, Feng
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 3501 - 3504
  • [47] Performance Evaluation of Various Pre-Processing Techniques for R-Peak Detection in ECG Signal
    Gupta, Varun
    Mittal, Monika
    Mittal, Vikas
    IETE JOURNAL OF RESEARCH, 2022, 68 (05) : 3267 - 3282
  • [48] Total Variation Denoising based Approach for R-peak Detection in ECG Signals
    Kumar, Sachin S.
    Mohan, Neethu
    Prabaharan, P.
    Soman, K. P.
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING AND COMMUNICATIONS, 2016, 93 : 697 - 705
  • [49] Adaptive R-Peak Detection Algorithm Based on Brown Exponential Smoothing Model
    Hao, Zihao
    Zhang, Xiaoming
    Lai, Zhengxi
    IEEE ACCESS, 2022, 10 : 114355 - 114363
  • [50] R Peak Detection in Electrocardiogram Signal Based on a Combination between Empirical Mode Decomposition and Hilbert Transform
    Mabrouki, Rebeh
    Khaddoumi, Balkine
    Sayadi, Mounir
    2014 1ST INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES FOR SIGNAL AND IMAGE PROCESSING (ATSIP 2014), 2014, : 183 - 187