An optimally designed digital differentiator based preprocessor for R-peak detection in electrocardiogram signal

被引:29
|
作者
Nayak, Chandan [1 ]
Saha, Suman Kumar [1 ]
Kar, Rajib [2 ]
Mandal, Durbadal [2 ]
机构
[1] NIT Raipur, Dept Elect & Telecommun Engn, Raipur 492010, Chhattisgarh, India
[2] NIT Durgapur, Dept Elect & Commun Engn, Durgapur 713209, W Bengal, India
关键词
Electrocardiogram (ECG); Gravitational search algorithm; Integer order digital differentiator; Hilbert transform; QRS complex detection; QRS-DETECTION ALGORITHM; AUTOMATIC DETECTION; OPTIMIZATION ALGORITHM; COMPLEX DETECTION; FIDUCIAL POINTS; ECG; HILBERT; FILTERS;
D O I
10.1016/j.bspc.2018.09.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Globally the human death rate is accelerating day by day due to the cardiovascular diseases (CVDs), and it will be elevated shortly. In this scenario, the QRS complex detection of electrocardiogram (ECG) signal is considered as a simple, non-invasive, inexpensive, and preliminary diagnosis method used to assess the cardiac health of a patient. In this paper, an optimally designed Integer Order Digital Differentiator (IODD) based preprocessor is proposed for the accurate estimation of R-peak locations in the ECG signal. IODD, one of the major constituents of the preprocessor, is designed most proficiently by using a metaheuristic evolutionary optimization method called Gravitational Search Algorithm (GSA). In GSA, as the number of iteration increases the exploration capability fades out, and the exploitation capability fades in, which help it to avoid the local optima stagnation problem and results in faster convergence. The IODD based preprocessor accentuates the QRS complexes of the ECG signal irrespective of its abnormal morphology. The employed detector is a simple threshold independent R-peak decision logic designed by utilizing the properties of the Hilbert transform. In order to emphasize the superiority of the proposed research work the proposed IODD based QRS detection approach is validated on the first channel records of MIT/BIH Arrhythmia database (MBAD), QT database (QTDB), MIT/BIH noise stress test database (NSTDB), atrial fibrillation termination challenge database (AFTDB), and MIT/BIH ST change database (STDB). The sensitivity (Se) and positive Predictivity (+P) values for MBAD, QTDB, NSTDB, AFTDB, and STDB are Se=99.92% and +P=99.92%, Se=99.98% and +P=99.96%, Se=95.23% and +P=94.41%, Se=99.03% and +P=99.76%, and Se=99.93% and +P=99.90%, respectively. These performance metrics ensure the accuracy of the proposed R-peak detection technique for a wide variety of QRS morphologies and thereby affirm the applicability of the proposed IODD for the efficient detection of R-peak locations. The performance of the proposed R-peak detector significantly outperforms the reported methods in terms of all the performance metrics. The enhanced QRS detection accuracy of the proposed approach is due to the better feature signal generating capability of the proposed IODD. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:440 / 464
页数:25
相关论文
共 50 条
  • [21] R-peak detection and signal averaging for simulated stress ECG using EMD
    Nimunkar, Amit J.
    Tompkins, Willis J.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1261 - 1264
  • [22] ECG Enhancement and R-Peak Detection Based on Window Variability
    Wu, Lu
    Xie, Xiaoyun
    Wang, Yinglong
    HEALTHCARE, 2021, 9 (02)
  • [23] Fetal Electrocardiogram R-peak Detection using Robust Tensor Decomposition and Extended Kalman Filtering
    Akhbari, Mahsa
    Niknazar, Mohammad
    Jutten, Christian
    Shamsollahi, Mohammad B.
    Rivet, Bertrand
    2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 189 - 192
  • [24] Comparison Between Linear and Nonlinear Haar Wavelet for the Detection of the R-peak in the Electrocardiogram of Small Animals
    Yamada, P. Y.
    Garcia, E., V
    XXVII BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2020, 2022, : 1967 - 1972
  • [25] A New LMS Based Noise Removal and DWT Based R-peak Detection in ECG Signal for Biotelemetry Applications
    S. Satheeskumaran
    M. Sabrigiriraj
    National Academy Science Letters, 2014, 37 : 341 - 349
  • [26] Modified automatic R-peak detection algorithm for patients with epilepsy using a portable electrocardiogram recorder
    Jeppesen, J.
    Beniczky, S.
    Frederiksen, A. Fuglsang
    Sidenius, P.
    Johansen, P.
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 4082 - 4085
  • [27] A New LMS Based Noise Removal and DWT Based R-peak Detection in ECG Signal for Biotelemetry Applications
    Satheeskumaran, S.
    Sabrigiriraj, M.
    NATIONAL ACADEMY SCIENCE LETTERS-INDIA, 2014, 37 (04): : 341 - 349
  • [28] Accurate ECG R-Peak Detection for Telemedicine
    Liao, Yangdong
    Na, Ru-Xin
    Rayside, Derek
    2014 IEEE CANADA INTERNATIONAL HUMANITARIAN TECHNOLOGY CONFERENCE (IHTC), 2014,
  • [29] A Novel Approach to ECG R-Peak Detection
    Amandeep Kaur
    Alpana Agarwal
    Ravinder Agarwal
    Sanjay Kumar
    Arabian Journal for Science and Engineering, 2019, 44 : 6679 - 6691
  • [30] A Novel Approach to ECG R-Peak Detection
    Kaur, Amandeep
    Agarwal, Alpana
    Agarwal, Ravinder
    Kumar, Sanjay
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2019, 44 (08) : 6679 - 6691