New Respiratory Gating Technique for Whole Heart Cine Imaging: Integration of a Navigator Slice in Steady State Free Precession Sequences

被引:9
作者
Uribe, Sergio [1 ,2 ,3 ]
Tejos, Cristian [3 ,4 ]
Razavi, Reza [2 ]
Schaeffter, Tobias [2 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Radiol, Santiago, Chile
[2] Guys & St Thomas NHS Fdn Trust, Kings Coll London, Div Imaging Sci, BHF Ctr,NIHR Biomed Res Ctr, London, England
[3] Pontificia Univ Catolica Chile, Biomed Imaging Ctr, Santiago, Chile
[4] Pontificia Univ Catolica Chile, Dept Elect Engn, Santiago, Chile
关键词
respiratory self-gating; whole heart imaging; k(o) projections; BALANCED SSFP; COMPENSATION; ANGIOGRAPHY; MRI;
D O I
10.1002/jmri.22625
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the performance of a slice navigator sequence integrated into a b-SSFP sequence for obtaining real time respiratory self-gated whole heart cine imaging. Materials and Methods: In this work, we present a novel and robust approach for respiratory motion detection by integrating a slice navigator sequence into a balanced steady state free precession (b-SSFP) sequence, while maintaining the steady state. The slice navigator sequence is integrated into consecutive repetition times (TRs) of a b-SSFP sequence to excite and read out a navigator slice. We performed several phantom experiments to test the performance of the slice navigator sequence. Additionally, the method was evaluated in five volunteers and compared with breathing signals obtained from conventional pencil beam navigator sequence. Finally, the navigator slice was used to obtain whole heart MR cine images. Results: The breathing signals detected by the proposed method showed an excellent agreement with those obtained from pencil beam navigators. Moreover, the technique was capable of removing respiratory motion artifacts with minimal distortion of the steady state. Image quality comparison showed a statistical significant improvement from a quality score of 2.1 obtained by the nonrespiratory gated images, compared to a quality score of 3.4 obtained by the respiratory gated images. Conclusion: This novel method represents a robust approach to estimate breathing motion during SSFP Imaging. The technique was successfully applied to acquire whole heart artifact-free cine images.
引用
收藏
页码:211 / 219
页数:9
相关论文
共 22 条
  • [1] Analysis and compensation of eddy currents in balanced SSFP
    Bieri, O
    Markl, M
    Scheffler, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) : 129 - 137
  • [2] Generalized self-navigated motion detection technique: Preliminary investigation in abdominal imaging
    Brau, ACS
    Brittain, JH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (02) : 263 - 270
  • [3] CURCIC J, 2008, P 11 ANN SCMR SCI SE
  • [4] PROJECTION ANGIOGRAMS OF BLOOD LABELED BY ADIABATIC FAST PASSAGE
    DIXON, WT
    DU, LN
    FAUL, DD
    GADO, M
    ROSSNICK, S
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (03) : 454 - 462
  • [5] ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES
    EHMAN, RL
    FELMLEE, JP
    [J]. RADIOLOGY, 1989, 173 (01) : 255 - 263
  • [6] Foo TKF, 1999, MAGN RESON MED, V42, P548, DOI 10.1002/(SICI)1522-2594(199909)42:3<548::AID-MRM17>3.0.CO
  • [7] 2-5
  • [8] Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    Griswold, MA
    Jakob, PM
    Heidemann, RM
    Nittka, M
    Jellus, V
    Wang, JM
    Kiefer, B
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1202 - 1210
  • [9] Accelerating cardiac Cine 3D Imaging using k-t BLAST
    Kozerke, S
    Tsao, J
    Razavi, R
    Boesiger, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 19 - 26
  • [10] Respiratory self-gated four-dimensional coronary MR angiography: A feasibility study
    Lai, Peng
    Larson, Andrew C.
    Park, Jaeseok
    Carr, James C.
    Li, Debiao
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (06) : 1378 - 1385