Boiler Tube Leakage Acoustic Localization Base on AGA

被引:1
|
作者
Wang, Peng [1 ]
An, Liansuo [1 ]
Shen, Guoqing [1 ]
Shi, Jie [1 ]
Lu, Yongxing [1 ]
机构
[1] N China Elect Power Univ, Key Lab Condit Monitoring & Control Power Plant E, Minist Educ, Beijing 102206, Peoples R China
来源
2010 8TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA) | 2010年
关键词
Boiler; leakage localizition; time differences of arrive; generalized cross correlation; accelerationg genetic algorithm; error;
D O I
10.1109/WCICA.2010.5553788
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Efficient and reliable operation is the main requirement of the modern power plant, hence it's significant that the boiler tube leakage source is localized precisely. The four-element acoustic array was exploited in the furnace and the schematic of sensors distributed for capture the leakage signal were given. A set of hyperbolic equations were established and Accelerating genetic algorithm (AGA) was proposed to give an iterative solution avoiding initial guess and far-field assumption. The stable and sharp peak can be obtained by an approximation of the maximum likelihood (ML) estimator, which was verified via the experiment on localization of leakage. The time differences of arrival (TDOA) error level was 0.1us, the array failed to fix position as the remarkable coordinate error, while the error level was 0.01us, the coordinates error was linearized and reduced to the permitted range (less than 1m).
引用
收藏
页码:3179 / 3183
页数:5
相关论文
共 50 条
  • [31] Prediction of tube temperature distribution of boiler platen superheater by a coupled combustion and hydrodynamic model
    Jin, Donghao
    Yan, Jingwen
    Liu, Xin
    Zhang, Chaoqun
    Wang, Heyang
    ENERGY, 2023, 279
  • [32] Failure investigation of a water-wall tube of fossil-fuel fired boiler
    Ranjeeth, R.
    Aditya, D.
    Gautam, Anil
    Singh, S. P.
    Bhattacharya, S.
    ENGINEERING FAILURE ANALYSIS, 2024, 155
  • [33] Failure investigation of platen superheater tube in a 210 MW thermal power plant boiler
    Ghosh, D.
    Roy, H.
    Sahoo, T. K.
    Shukla, A. K.
    TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2010, 63 (2-3): : 687 - 690
  • [34] Effect of tube pitch ratio of in-line tube banks on acoustic resonance and vortex shedding
    Hamakawa, Hiromitsu
    Harada, Hiroki
    Shibayama, Kazuki
    Kurihara, Eru
    Nishida, Eiichi
    JOURNAL OF FLUID SCIENCE AND TECHNOLOGY, 2023, 18 (01):
  • [35] A Study on Bituminous Coal Base Acid Ratio to the Slagging Factor at Large Scale Boiler
    Samsudin, Salmi
    Aziz, Nuraini Abdul
    Hairuddin, Abdul Aziz
    Masuri, Siti Ujila
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2021, 39 (03) : 833 - 840
  • [36] Acoustic source localization with deep generalized cross correlations
    Manuel Vera-Diaz, Juan
    Pizarro, Daniel
    Macias-Guarasa, Javier
    SIGNAL PROCESSING, 2021, 187
  • [37] Hot Corrosion Behaviour of Different Ceramics Coatings on Boiler Tube Steel at 800 °C Temperature
    Singh A.
    Goyal K.
    Goyal R.
    Krishan B.
    Journal of Bio- and Tribo-Corrosion, 2021, 7 (01)
  • [38] Failure Analysis and Magnetic Evaluation of Tertiary Superheater Tube Used in Gas-Fired Boiler
    Mohapatra, J. N.
    Patil, Sujay
    Sah, Rameshwar
    Krishna, P. C.
    Eswarappa, B.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2018, 27 (02) : 580 - 589
  • [39] Failure Analysis and Magnetic Evaluation of Tertiary Superheater Tube Used in Gas-Fired Boiler
    J. N. Mohapatra
    Sujay Patil
    Rameshwar Sah
    P. C. Krishna
    B. Eswarappa
    Journal of Materials Engineering and Performance, 2018, 27 : 580 - 589
  • [40] Prediction of the tube temperature and oxide scale formation of boiler superheater by a coupled combustion and hydrodynamic model
    Yin, Hengyu
    Jin, Donghao
    Liu, Xin
    Li, Chi
    Li, Xinying
    Wang, Heyang
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2025, 163