The Immunological Effect of Oxygen Carriers on Normothermic Ex Vivo Liver Perfusion

被引:3
|
作者
Jennings, Heather [1 ]
Carlson, Kristin N. N. [1 ]
Little, Chris [1 ]
Verhagen, Joshua C. C. [1 ]
Nagendran, Jeevan [2 ]
Liu, Yongjun [3 ]
Verhoven, Bret [1 ]
Zeng, Weifeng [1 ]
McMorrow, Stacey [1 ]
Chlebeck, Peter [1 ]
Al-Adra, David P. P. [1 ]
机构
[1] Univ Wisconsin, Sch Med & Publ Hlth, Dept Surg, Div Transplantat, Madison, WI 53706 USA
[2] Univ Alberta, Dept Surg, Edmonton, AB, Canada
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Pathol, Madison, WI USA
来源
FRONTIERS IN IMMUNOLOGY | 2022年 / 13卷
关键词
liver; transplantation; normothermic perfusion; oxygen carrier; immune system; TRANSPLANTATION; PRESERVATION; IMPROVES; DISEASE; CELLS;
D O I
10.3389/fimmu.2022.833243
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
IntroductionNormothermic ex vivo liver perfusion (NEVLP) is an organ preservation method that allows liver graft functional assessment prior to transplantation. One key component of normothermic perfusion solution is an oxygen carrier to provide oxygen to the liver to sustain metabolic activities. Oxygen carriers such as red blood cells (RBCs) or hemoglobin-based oxygen carriers have an unknown effect on the liver-resident immune cells during NEVLP. In this study, we assessed the effects of different oxygen carriers on the phenotype and function of liver-resident immune cells. MethodsAdult Lewis rat livers underwent NEVLP using three different oxygen carriers: human packed RBCs (pRBCs), rat pRBCs, or Oxyglobin (a synthetic hemoglobin-based oxygen carrier). Hourly perfusate samples were collected for downstream analysis, and livers were digested to isolate immune cells. The concentration of common cytokines was measured in the perfusate, and the immune cells underwent phenotypic characterization with flow cytometry and quantitative reverse transcription polymerase chain reaction (qRT-PCR). The stimulatory function of the liver-resident immune cells was assessed using mixed lymphocyte reactions. ResultsThere were no differences in liver function, liver damage, or histology between the three oxygen carriers. qRT-PCR revealed that the gene expression of nuclear factor kappa light chain enhancer of activated B cells (NF-kB), Interleukin (IL-1 beta), C-C motif chemokine ligand 2 (CCL2), C-C motif chemokine ligand 7 (CCL7), and CD14 was significantly upregulated in the human pRBC group compared with that in the naive, whereas the rat pRBC and Oxyglobin groups were not different from that of naive. Flow cytometry demonstrated that the cell surface expression of the immune co-stimulatory protein, CD86, was significantly higher on liver-resident macrophages and plasmacytoid dendritic cells perfused with human pRBC compared to Oxyglobin. Mixed lymphocyte reactions revealed increased allogeneic T-cell proliferation in the human and rat pRBC groups compared to that in the Oxyglobin group. ConclusionsLiver-resident immune cells are important mediators of rejection after transplantation. In this study, we show that the oxygen carrier used in NEVLP solutions can affect the phenotype of these liver-resident immune cells. The synthetic hemoglobin-based oxygen carrier, Oxyglobin, showed the least amount of liver-resident immune cell activation and the least amount of allogeneic proliferation when compared to human or rat pRBCs. To mitigate liver-resident immune cell activation during NEVLP (and subsequent transplantation), Oxyglobin may be an optimal oxygen carrier.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Normothermic Ex Vivo Liver Machine Perfusion in Mouse
    Chen, Haotian
    Dirsch, Olaf
    Albadry, Mohamed
    Ana, Paz Hernandez
    Dahmen, Uta
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (199):
  • [2] Blood Is Not Required for Normothermic Ex Vivo Liver Perfusion
    Boehnert, M. U.
    Yeung, J. C.
    Knaak, J. -M.
    Bazerbachi, F.
    Selzner, N.
    Keshavjee, S.
    Levy, G. A.
    Grant, D. R.
    Selzner, M.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2012, 12 : 226 - 226
  • [3] Ex-vivo normothermic liver perfusion: an update
    Vogel, Thomas
    Brockmann, Jens G.
    Friend, Peter J.
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2010, 15 (02) : 167 - 172
  • [4] Normothermic and subnormothermic ex-vivo liver perfusion in liver transplantation
    Goldaracena, Nicolas
    Barbas, Andrew S.
    Selzner, Markus
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2016, 21 (03) : 315 - 321
  • [5] A Small Animal Model of Ex Vivo Normothermic Liver Perfusion
    Beal, Eliza W.
    Dumond, Curtis
    Kim, Jung-Lye
    Akateh, Clifford
    Eren, Emre
    Maynard, Katelyn
    Sen, Chandan K.
    Zweier, Jay L.
    Washburn, Kenneth
    Whitson, Bryan A.
    Black, Sylvester M.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (136):
  • [6] Clearance of Transaminases During Normothermic Ex Vivo Liver Perfusion
    Bral, M.
    Aboelnazar, N.
    Gala-Lopez, B.
    Hatami, S.
    Freed, D.
    Shapiro, A.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2017, 17 : 467 - 467
  • [7] Normothermic Ex-vivo Liver Perfusion and the Clinical Implications for Liver Transplantation
    Akateh, Clifford
    Beal, Eliza W.
    Whitson, Bryan A.
    Black, Sylvester M.
    JOURNAL OF CLINICAL AND TRANSLATIONAL HEPATOLOGY, 2018, 6 (03) : 276 - 282
  • [8] An adaptable research platform for ex vivo normothermic machine perfusion of the liver
    Magbagbeola, M.
    Rai, Z. L.
    Doyle, K.
    Lindenroth, L.
    Dwyer, G.
    Gander, A.
    Stilli, A.
    Davidson, B. R.
    Stoyanov, D.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2023, 18 (06) : 1101 - 1108
  • [9] Ex-vivo liver splitting during normothermic machine perfusion
    Lau, N. -S.
    Ly, M.
    Ewenson, K.
    Ly, H.
    Huang, J. L.
    Chanda, S.
    Wang, C.
    Liu, K.
    McCaughan, G.
    Crawford, M.
    Pulitano, C.
    TRANSPLANTATION, 2022, 106 (8S) : 63 - 63
  • [10] An adaptable research platform for ex vivo normothermic machine perfusion of the liver
    M. Magbagbeola
    Z. L. Rai
    K. Doyle
    L. Lindenroth
    G. Dwyer
    A. Gander
    A. Stilli
    B. R. Davidson
    D. Stoyanov
    International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 1101 - 1108