Multispectral imaging with three-dimensional rosette trajectories

被引:12
作者
Bucholz, Elizabeth K. [1 ,2 ]
Song, Jiayu [1 ,3 ]
Johnson, Allan [1 ,2 ]
Hancu, Ileana
机构
[1] Duke Univ, Ctr Vivo Microscopy, Durham, NC USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[3] Duke Univ, Dept Elect & Comp Engn, Durham, NC 27706 USA
关键词
rosette; multispectral; 3D; density compensation function;
D O I
10.1002/mrm.21551
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two-dimensional intersecting k-space trajectories have previously been demonstrated to allow fast multispectral imaging. Repeated sampling of k-space points leads to destructive interference of the signal coming from the off-resonance spectral peaks; on-resonance data reconstruction yields images of the on-resonance peak, with some of the off-resonance energy being spread as noise in the image. A shift of the k-space data by a given off-resonance frequency brings a second frequency of interest on resonance, allowing the reconstruction of a second spectral peak from the same k-space data. Given the higher signal-to-noise per unit time characteristic of a 3D acquisition, we extended the concept of intersecting trajectories to three dimensions. A 3D, rosette-like pulse sequence was designed and implemented on a clinical 1.5T scanner. An iterative density compensation function was developed to weight the 3D intersecting trajectories before Fourier transformation. Three volunteers were scanned using this sequence and separate fat and water images were reconstructed from the same imaging dataset.
引用
收藏
页码:581 / 589
页数:9
相关论文
共 30 条
  • [1] Analysis of multiple-acquisition SSFP
    Bangerter, NK
    Hargreaves, BA
    Vasanawala, SS
    Pauly, JM
    Gold, GE
    Nishimura, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) : 1038 - 1047
  • [2] NMR CHEMICAL-SHIFT IMAGING IN 3 DIMENSIONS
    BROWN, TR
    KINCAID, BM
    UGURBIL, K
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1982, 79 (11): : 3523 - 3526
  • [3] A SIGNAL-TO-NOISE CALIBRATION PROCEDURE FOR NMR IMAGING-SYSTEMS
    EDELSTEIN, WA
    BOTTOMLEY, PA
    PFEIFER, LM
    [J]. MEDICAL PHYSICS, 1984, 11 (02) : 180 - 185
  • [4] Real-time metabolic imaging
    Golman, Klaes
    in't Zandt, Rene
    Thaning, Mikkel
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (30) : 11270 - 11275
  • [5] Density compensation functions for spiral MRI
    Hoge, RD
    Kwan, RKS
    Pike, GB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) : 117 - 128
  • [6] SELECTION OF A CONVOLUTION FUNCTION FOR FOURIER INVERSION USING GRIDDING
    JACKSON, JI
    MEYER, CH
    NISHIMURA, DG
    MACOVSKI, A
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) : 473 - 478
  • [7] Cerebral perfusion assessment by bolus tracking using hyperpolarized 13C
    Johansson, E
    Månsson, S
    Wirestam, R
    Svesson, J
    Petersson, S
    Golman, K
    Ståhlberg, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) : 464 - 472
  • [8] Spiral readout gradients for the reduction of motion artifacts in chemical shift imaging
    Kim, DH
    Adalsteinsson, E
    Spielman, DM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) : 458 - 463
  • [9] Advantages of parallel imaging in conjunction with hyperpolarized helium- A new approach to MRI of the lung
    Lee, RF
    Johnson, G
    Grossman, RI
    Stoeckel, B
    Trampel, R
    McGuinness, G
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) : 1132 - 1141
  • [10] Levenson RM, 2000, AM LAB, V32, P26