Sensitive determination of epinephrine in pharmaceutical preparation by flow injection coupled with chemiluminescence detection and mechanism study

被引:21
作者
Liu, Yanming [1 ]
Liu, Zhuanli [1 ]
Shi, Yanmei [1 ]
机构
[1] Xinyang Normal Univ, Coll Chem & Chem Engn, Xinyang 464000, Peoples R China
基金
中国国家自然科学基金;
关键词
chemiluminescence; flow-injection; epinephrine; mechanism study; CAPILLARY-ELECTROPHORESIS; GOLD NANOPARTICLE; ELECTROCHEMILUMINESCENCE DETECTION; SPECTROPHOTOMETRIC DETERMINATION; HUMAN URINE; HUMAN SERUM; SYSTEM; CATECHOLAMINES; FORMULATIONS; NOREPINEPHRINE;
D O I
10.1002/bio.1186
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel, rapid and sensitive method was described for the determination of epinephrine (EP) using flow injection analysis coupled with chemiluminescence (CL) detection, which based on EP enhanced the weak CL emission of luminol-KIO(4) system in NaOH solution. Parameters affecting the CL intensity and reproducibility were optimized systematically. Under the optimized experiment conditions, the net CL intensity was proportional to the concentration of EP in the range of 5.0 x 10(-8) to 1.5 x 10(-6) mol/L with a detection limit of 1.9 x 10(-9) mol/L. The relative standard deviation (RSD) was found to be 0.7% for 13 replicate determinations of 3.0 x 10(-7) mol/L EP. The applicability of the proposed method was illustrated in the determination of EP in pharmaceutical preparation. The recoveries of EP at different levels in EP hydrochloride injection were between 95.4 and 104.7%. One assay procedure takes only 27 s, and the sampling rate was calculated about to be 130 samples/h. The possible mechanism of the enhanced CL intensity was studied by examining CL spectra and UV-vis spectra. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 50 条
  • [41] Sensitive Determination of Bovine Serum Albumin by Flow-Injection Chemiluminescence
    Du Jun-jun
    Wang Hui
    Ren Shu-wei
    Zhou Min
    Liu Ying-ying
    Liu Yan-ming
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (06) : 1693 - 1696
  • [42] Sensitive determination of Fenamiphos in water samples by flow injection photoinduced chemiluminescence
    Gomez-Benito, Carmen
    Meseguer-Lloret, Susana
    Torres-Cartas, Sagrario
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (02) : 152 - 165
  • [43] Flow injection-chemiluminescence determination of dopamine using potassium permanganate and formaldehyde system
    Wabaidur, Saikh Mohammad
    Alothman, Zeid Abdullah
    Alam, Seikh Mafiz
    Lee, Sang Hak
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2012, 96 : 221 - 225
  • [44] Determination of dopamine by flow-injection analysis coupled with luminol-hexacyanoferrate(III) chemiluminescence detection
    Nalewajko, E
    Ramírez, RB
    Kojlo, A
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (01) : 219 - 223
  • [45] Peroxyoxalate Photoinduced Chemiluminescence Detection of Norfloxacin in Pharmaceutical Products by Flow Injection Analysis
    Moreno-Gonzalez, David
    Garcia-Campana, Ana M.
    Gonzalez-Casado, Antonio
    ANALYTICAL LETTERS, 2010, 43 (15) : 2399 - 2410
  • [46] Highly sensitive trivalent copper chelate-luminol chemiluminescence system for capillary electrophoresis detection of epinephrine in the urine of smoker
    Li, Tao
    Wang, Zuorong
    Xie, Haoyue
    Fu, Zhifeng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 911 : 1 - 5
  • [47] A Sensitive Procedure for the Rapid Determination of Mandelic Acid by Flow Injection Analysis and Chemiluminescence Detection
    Alam, Seikh Mafiz
    Jeon, Chi Wan
    Karim, Mohammad Mainul
    Lee, Sang Hak
    Wabaidur, Saikh Mohammad
    Suh, Yeoun Suk
    Chung, Hye Young
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2009, 30 (01): : 102 - 106
  • [48] Determination of Picogram Levels of Levodopa in Pharmaceutical Preparations and Biofluids by Flow-Injection Chemiluminescence
    Zhang, Yun
    Gao, Suya
    BIOTECHNOLOGY, CHEMICAL AND MATERIALS ENGINEERING III, PTS 1 AND 2, 2014, 884-885 : 566 - 569
  • [49] Flow injection chemiluminescence analysis for highly sensitive determination of noscapine
    Zhuang, YF
    Cai, XL
    Yu, JS
    Ju, HX
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2004, 162 (2-3) : 457 - 462
  • [50] Determination of Cytochrome c in Human Serum and Pharmaceutical Injections Using Flow Injection Chemiluminescence
    Xin Li
    Houyong Liu
    Xili He
    Zhenghua Song