Sensitive determination of epinephrine in pharmaceutical preparation by flow injection coupled with chemiluminescence detection and mechanism study

被引:21
作者
Liu, Yanming [1 ]
Liu, Zhuanli [1 ]
Shi, Yanmei [1 ]
机构
[1] Xinyang Normal Univ, Coll Chem & Chem Engn, Xinyang 464000, Peoples R China
基金
中国国家自然科学基金;
关键词
chemiluminescence; flow-injection; epinephrine; mechanism study; CAPILLARY-ELECTROPHORESIS; GOLD NANOPARTICLE; ELECTROCHEMILUMINESCENCE DETECTION; SPECTROPHOTOMETRIC DETERMINATION; HUMAN URINE; HUMAN SERUM; SYSTEM; CATECHOLAMINES; FORMULATIONS; NOREPINEPHRINE;
D O I
10.1002/bio.1186
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel, rapid and sensitive method was described for the determination of epinephrine (EP) using flow injection analysis coupled with chemiluminescence (CL) detection, which based on EP enhanced the weak CL emission of luminol-KIO(4) system in NaOH solution. Parameters affecting the CL intensity and reproducibility were optimized systematically. Under the optimized experiment conditions, the net CL intensity was proportional to the concentration of EP in the range of 5.0 x 10(-8) to 1.5 x 10(-6) mol/L with a detection limit of 1.9 x 10(-9) mol/L. The relative standard deviation (RSD) was found to be 0.7% for 13 replicate determinations of 3.0 x 10(-7) mol/L EP. The applicability of the proposed method was illustrated in the determination of EP in pharmaceutical preparation. The recoveries of EP at different levels in EP hydrochloride injection were between 95.4 and 104.7%. One assay procedure takes only 27 s, and the sampling rate was calculated about to be 130 samples/h. The possible mechanism of the enhanced CL intensity was studied by examining CL spectra and UV-vis spectra. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 39 条
[1]   The determination of levofloxacin by flow injection analysis using UV detection, potentiometry, and conductometry in pharmaceutical preparations [J].
Altiokka, G ;
Atkosar, Z ;
Can, NO .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) :881-885
[2]   Flow injection screening and semiquantitative determination of polycyclic aromatic hydrocarbons in water by laser induced spectrofluorimetry -: chemometrics [J].
Amador-Hernández, J ;
Fernández-Romero, JM ;
de Castro, MDL .
ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) :61-69
[3]   A fast screening method for the presence of atrazine and other triazines in water using flow injection with chemiluminescent detection [J].
Beale, David J. ;
Porter, Nichola A. ;
Roddick, Felicity A. .
TALANTA, 2009, 78 (02) :342-347
[4]  
Deftereoss TN, 1993, ANALYST, V118, P627
[5]   Ultrasensitive flow injection chemiluminescence detection of DNA hybridization using nanoCuS tags [J].
Ding, Caifeng ;
Zhong, Hua ;
Zhang, Shusheng .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (08) :1314-1318
[6]   Epinephrine quantification in pharmaceutical formulations utilizing plant tissue biosensors [J].
Felix, Fabiana S. ;
Yamashita, Miyuki ;
Angnes, Lucio .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (12) :2283-2289
[7]   Chemiluminescence method for the determination of glutathione in human serum using the Ru( phen)32+ -: KMnO4 system [J].
Han, He-You ;
He, Zhi-Ke ;
Zeng, Yun-E .
MICROCHIMICA ACTA, 2006, 155 (3-4) :431-434
[8]   Cyclic voltammetry determination of epinephrine with a carbon fiber ultramicroelectrode [J].
Hernandez, P ;
Sanchez, I ;
Paton, F ;
Hernandez, L .
TALANTA, 1998, 46 (05) :985-991
[9]   Indirect chemiluminescence detection for capillary zone electrophoresis of monoamines and catechol using luminol-K3[Fe(CN)6] system [J].
Hu, YG ;
Li, XX ;
Pang, ZT .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1091 (1-2) :194-198
[10]   Flow-injection chemiluminescence determination of phentolamine based on its enhancing effect on the luminol-potassium ferricyanide system [J].
Huang, YM ;
Liu, WB .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 38 (03) :537-542