An Integrated Platform for Advanced Diagnostics

被引:0
作者
De Micheli, Giovanni [1 ]
Ghoreishizadeh, S. Sara [1 ]
Boero, Cristina [1 ]
Valgimigli, Francesco [2 ]
Carrara, Sandro [1 ]
机构
[1] Ecole Polytech Fed Lausanne, LSI, Lausanne, Switzerland
[2] A Menarini Diagnost, Florence, Italy
来源
2011 DESIGN, AUTOMATION & TEST IN EUROPE (DATE) | 2011年
关键词
biosensor; integrated circuit; metabolite; oxidase; cytochrome P450; potentiostat; DNA SENSOR; BIOSENSOR; ELECTROCHEMISTRY; CHOLESTEROL; FABRICATION; ELECTRODES; LACTATE; GLUCOSE; CONVERSION; OXIDASE;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The objective of this work is the systematic study of the use of electrochemical readout for advanced diagnosis and drug monitoring. Whereas to date various electrochemical principles have been studied and successfully tested, they typically operate on a single target molecule and are not integrated in a full data analysis chain. The present work aims to view various sensing approaches and explore the design space for integrated realization of multi-target sensors and sensor arrays.
引用
收藏
页码:1454 / 1459
页数:6
相关论文
共 30 条
[1]   A very low power CMOS potentiostat for bioimplantable applications [J].
Ahmadi, MM ;
Jullien, GA .
FIFTH INTERNATIONAL WORKSHOP ON SYSTEM-ON-CHIP FOR REAL-TIME APPLICATIONS, PROCEEDINGS, 2005, :184-189
[2]  
Antonini M, 2003, IEE Proc Nanobiotechnol, V150, P31, DOI 10.1049/ip-nbt:20030534
[3]   Screen-printed electrodes based on carbon nanotubes and cytochrome P450scc for highly sensitive cholesterol biosensors [J].
Carrara, Sandro ;
Shumyantseva, Victoria V. ;
Archakov, Alexander I. ;
Samori, Bruno .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (01) :148-150
[4]   Disposable glucose test strip for whole blood with integrated sensing/diffusion-limiting layer [J].
Chen, Zhencheng ;
Fang, Cheng ;
Wang, Hongyan ;
He, Jishan .
ELECTROCHIMICA ACTA, 2009, 55 (02) :544-550
[5]  
De Venuto D., 2010, P IEEE SENS C
[6]  
EGGINS BR, CHEM SENSORS BIOSENS, P125
[7]   Direct electrochemistry of immobilized human cytochrome P450 2E1 [J].
Fantuzzi, A ;
Fairhead, M ;
Gilardi, G .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (16) :5040-5041
[8]   Function of an Implanted Tissue Glucose Sensor for More than 1 Year in Animals [J].
Gough, David A. ;
Kumosa, Lucas S. ;
Routh, Timothy L. ;
Lin, Joe T. ;
Lucisano, Joseph Y. .
SCIENCE TRANSLATIONAL MEDICINE, 2010, 2 (42)
[9]   Design of a subcutaneous implantable biochip for monitoring of glucose and lactate [J].
Guiseppi-Elie, A ;
Brahim, S ;
Slaughter, G ;
Ward, KR .
IEEE SENSORS JOURNAL, 2005, 5 (03) :345-355
[10]   Microsomal cytochrome P450-3A4 (CYP3A4) nanobiosensor for the determination of 2,4-dichlorophenol-An endocrine disruptor compound [J].
Hendricks, Nicolette R. ;
Waryo, Tesfaye T. ;
Arotiba, Omotayo ;
Jahed, Nazeem ;
Baker, Priscilla G. L. ;
Iwuoha, Emmanuel I. .
ELECTROCHIMICA ACTA, 2009, 54 (07) :1925-1931