An unexpected complication after harvesting of the radial artery for coronary artery bypass grafting

被引:64
作者
Nunoo-Mensah, J [1 ]
机构
[1] John Radcliffe Hosp, Dept Cardiothorac Surg, Oxford OX3 9DT, England
关键词
D O I
10.1016/S0003-4975(98)00559-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Acute ischemia of the hand developed after coronary artery bypass grafting with a radial artery conduit. Perioperative tests established that there was good perfusion to the hand via the collateral vessels. Angiographic examination showed an absence of the ulnar artery. Circulation was restored with a vein graft. I briefly review noninvasive investigations available and suggest that color Doppler scanning should be routinely performed before the use of the radial artery as a conduit. (Ann Thorac Surg 1998;66:929-31) (C) 1998 by The Society of Thoracic Surgeons.
引用
收藏
页码:929 / 931
页数:3
相关论文
共 8 条
  • [1] REVIVAL OF THE RADIAL ARTERY FOR CORONARY-ARTERY BYPASS-GRAFTING
    ACAR, C
    JEBARA, VA
    PORTOGHESE, M
    BEYSSEN, B
    PAGNY, JY
    GRARE, P
    CHACHQUES, JC
    FABIANI, JN
    DELOCHE, A
    GUERMONPREZ, JL
    CARPENTIER, AF
    [J]. ANNALS OF THORACIC SURGERY, 1992, 54 (04) : 652 - 660
  • [2] RADIAL ARTERY AND INFERIOR EPIGASTRIC ARTERY IN COMPOSITE GRAFTS - IMPROVED MIDTERM ANGIOGRAPHIC RESULTS
    CALAFIORE, AM
    DIGIAMMARCO, G
    TEODORI, G
    DANNUNZIO, E
    VITOLLA, G
    FINO, C
    MADDESTRA, N
    [J]. ANNALS OF THORACIC SURGERY, 1995, 60 (03) : 517 - 524
  • [3] DIETL CA, 1995, ANN THORAC SURG, V60, P102
  • [4] PHOTO-ELECTRIC PLETHYSMOGRAPHY AS A MONITORING DEVICE IN ANESTHESIA - APPLICATION AND INTERPRETATION
    DORLAS, JC
    NIJBOER, JA
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1985, 57 (05) : 524 - 530
  • [5] COMPARISON OF DIGITAL BLOOD-PRESSURE, PLETHYSMOGRAPHY, AND THE MODIFIED ALLEN TEST AS MEANS OF EVALUATING THE COLLATERAL CIRCULATION TO THE HAND
    FUHRMAN, TM
    REILLEY, TE
    PIPPIN, WD
    [J]. ANAESTHESIA, 1992, 47 (11) : 959 - 961
  • [6] BLOOD-FLOW LIMITS AND PULSE OXIMETER SIGNAL-DETECTION
    LAWSON, D
    NORLEY, I
    KORBON, G
    LOEB, R
    ELLIS, J
    [J]. ANESTHESIOLOGY, 1987, 67 (04) : 599 - 603
  • [7] CIRCULATORY PATTERNS IN NORMAL HAND
    LITTLE, JM
    ZYLSTRA, PL
    WEST, J
    MAY, J
    [J]. BRITISH JOURNAL OF SURGERY, 1973, 60 (08) : 652 - 655
  • [8] COLOR-FLOW DOPPLER - IMAGING THE UPPER EXTREMITY
    TRAGER, S
    PIGNATARO, M
    ANDERSON, J
    KLEINERT, JM
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (04): : 621 - 625