Myocardial Strain Measurement With 2-Dimensional Speckle-Tracking Echocardiography Definition of Normal Range

被引:422
作者
Marwick, Thomas H. [1 ]
Leano, Rodel L.
Brown, Joseph
Sun, Jing-Ping [2 ]
Hoffmann, Rainer [3 ]
Lysyansky, Peter [4 ]
Becker, Michael [3 ]
Thomas, James D. [2 ]
机构
[1] Univ Queensland, Princess Alexandra Hosp, Dept Med, Brisbane, Qld 4102, Australia
[2] Cleveland Clin, Cleveland, OH 44106 USA
[3] RWTH Hosp, Aachen, Germany
[4] Gen Elect Med Syst, Haifa, Israel
关键词
regional left ventricular function; strain; speckle tracking; DEFORMATION;
D O I
10.1016/j.jcmg.2007.12.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The interpretation of wall motion is an important component of echocardiography but remains a source of variation between observers. It has been believed that automated quantification of left ventricular (LV) systolic function by measurement of LV systolic strain from speckle-tracking echocardiography might be helpful. This multicenter study of nearly 250 volunteers without evidence of cardiovascular disease showed an average LV peak systolic strain of -18.6 +/- 0.1%. Although strain was influenced by weight, blood pressure, and heart rate, these features accounted for only 16% of variance. However, there was significant segmental variation of regional strain to necessitate the use of site-specific normal ranges. (J Am Coll Cardiol Img 2009;2:80-4) (C) 2009 by the American College of Cardiology Foundation
引用
收藏
页码:80 / 84
页数:5
相关论文
共 4 条
[1]   Quantitative assessment of intrinsic regional myocardial deformation by Doppler strain rate echocardiography in humans - Validation against three-dimensional tagged magnetic resonance imaging [J].
Edvardsen, T ;
Gerber, BL ;
Garot, J ;
Bluemke, DA ;
Lima, JAC ;
Smiseth, OA .
CIRCULATION, 2002, 106 (01) :50-56
[2]   Can natural strain and strain rate quantify regional myocardial deformation? A study in healthy subjects [J].
Kowalski, M ;
Kukulski, T ;
Jamal, F ;
D'Hooge, J ;
Weidemann, F ;
Rademakers, F ;
Bijnens, B ;
Hatle, L ;
Sutherland, GR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (08) :1087-1097
[3]   Two-dimensional strain - A novel software for real-time quantitative echocardiographic assessment of myocardial function [J].
Leitman, M ;
Lysyansky, P ;
Sidenko, S ;
Shir, V ;
Peleg, E ;
Binenbaum, M ;
Kaluski, E ;
Krakover, R ;
Vered, Z .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (10) :1021-1029
[4]   Noninvasive quantification of regional myocardial function using Doppler-derived velocity, displacement, strain rate, and strain in healthy volunteers: Effects of aging [J].
Sun, JP ;
Popovic, ZB ;
Greenberg, NL ;
Xu, XF ;
Asher, CR ;
Stewart, WJ ;
Thomas, JD .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (02) :132-+