Distance between the descending aorta and the left inferior pulmonary vein as a determinant of biophysical parameters during paroxysmal atrial fibrillation cryoablation

被引:2
作者
Benali, Karim [1 ,2 ]
Da Costa, Antoine [1 ]
Macle, Laurent [3 ]
Hammache, Nefissa [2 ,4 ]
Galand, Vincent [5 ]
Romeyer, Cecile [1 ]
Guichard, Jean Baptiste [1 ]
Leclercq, Christophe [5 ]
Pavin, Dominique [5 ]
Martins, Raphael [5 ,6 ]
机构
[1] St Etienne Univ Hosp, Dept Cardiol, St Priest En Jarez, France
[2] Univ Nancy, CHU Nancy, U947, INSERM IADI, Vandoeuvre Les Nancy, France
[3] Montreal Heart Inst, Dept Med, Electrophysiol Serv, Montreal, PQ, Canada
[4] Nancy Univ Hosp, Dept Cardiol, Vandoeuvre Les Nancy, France
[5] Rennes Univ Hosp, Dept Cardiol, Rennes, France
[6] Univ Rennes, U1099, INSERM LTSI, CHU Rennes, Rennes, France
关键词
aorta; aortic imprint; atrial fibrillation; blood flow; cryoablation; cryoballoon; cryolesion; left inferior pulmonary vein; temperature; CRYOBALLOON-ABLATION; 2ND-GENERATION CRYOBALLOON; RADIOFREQUENCY ABLATION; CATHETER ABLATION; EFFICACY; TIME; SAFETY; CRYO;
D O I
10.1111/jce.15234
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The distance from the descending aorta (DA) to the posterior wall of the left atrium (LA) is variable. We aimed to determine whether the proximity between the DA and the left inferior pulmonary vein (LIPV) ostium has an impact on biophysical parameters and cryoballoon (CB) ablation efficacy during LIPV freezing. Methods Patients referred for CB-ablation of atrial fibrillation (AF) in two high-volume centers were included. Cryoablation data were collected prospectively for each patient. The anatomical relationships between the LIPV and the DA (distance LIPV ostium-DA, presence of an aortic imprint on the posterior aspect of the LIPV) were then retrospectively analysed on the LA computed tomography scans realized before AF ablation. Results A total of 350 patients were included (70% men, 59.7 +/- 11.5 years). The decrease in the Ostium-DA distance was significantly correlated to the increase in the time-to-isolation (TTI) (r = -.31; p = .036), with less negative temperature (r = -.11; p = .045). Similarly, the presence of an aortic imprint on the LIPV was associated with a longer TTI (p < .001). The analysis of redo procedures data shows a trend toward the presence of shorter ostium-DA distances (15.3 +/- 3.29 vs. 18.1 +/- 4.99, p = .15) and more frequent aortic imprints (63.6% vs. 47.5%, p = .34) in patients with LIPV reconnection as opposed to patients without reconnection in the LIPV. Conclusion Our findings indicated that the DA seems to have a "radiator" effect influencing LIPV cryoablation parameters during CB-ablation. Additional studies will be needed to elucidate whether this biophysical influence has a clinical impact in LIPVs reconnections.
引用
收藏
页码:2943 / 2952
页数:10
相关论文
共 35 条
  • [21] Safety and efficacy of a second-generation cryoballoon in the ablation of paroxysmal atrial fibrillation
    Martins, Raphael P.
    Hamon, David
    Cesari, Olivier
    Behaghel, Albin
    Behar, Nathalie
    Sellal, Jean-Marc
    Daubert, Jean-Claude
    Mabo, Philippe
    Pavin, Dominique
    [J]. HEART RHYTHM, 2014, 11 (03) : 386 - 393
  • [22] Cryoballoon ablation during atrial fibrillation is associated with faster temperature drop and lower freezing temperatures
    Mugnai, Giacomo
    Moran, Darragh
    Stroker, Erwin
    Ruggiero, Diego
    Coutino-Moreno, Hugo Enrique
    Takarada, Ken
    De Regibus, Valentina
    Choudhury, Rajin
    Iacopino, Saverio
    Filannino, Pasquale
    Umbrain, Vincent
    Beckers, Stefan
    Brugada, Pedro
    de Asmundis, Carlo
    Chierchia, Gian-Battista
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 47 (03) : 357 - 364
  • [23] Cryoballoon Pulmonary Vein Isolation Supported by Intracardiac Echocardiography: Integration of a Nonfluoroscopic Imaging Technique in Atrial Fibrillation Ablation
    Noelker, Georg
    Heintze, Johannes
    Gutleben, Klaus-Juergen
    Muntean, Bogdan
    Puetz, Vanessa
    Yalda, Ameera
    Vogt, Juergen
    Horstkotte, Dieter
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (12) : 1325 - 1330
  • [24] Arterial Clamping Increases Central Renal Cryoablation Efficacy: An Animal Study
    Nonboe, Lasse L.
    Nielsen, Tommy K.
    Hoyer, Soren
    Graumann, Ole
    Frokiaer, Jorgen
    Borre, Michael
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (04) : 414 - 420
  • [25] Cryoballoon ablation of atrial fibrillation in patients with atypical right pulmonary vein anatomy
    Pichard, Camille
    Nicolas, Amelie
    Galand, Vincent
    Coquard, Charlene
    Behar, Nathalie
    Cherel, Celine
    Daubert, Jean-Claude
    Mabo, Philippe
    Leclercq, Christophe
    Pavin, Dominique
    Lederlin, Mathieu
    Martins, Raphael P.
    [J]. ARCHIVES OF CARDIOVASCULAR DISEASES, 2020, 113 (11) : 690 - 700
  • [26] Contrasting effects of convective flow on catheter ablation lesion size: Cryo versus radiofrequency energy
    Pilcher, Thomas A.
    Saul, J. Philip
    Hlavacek, Anthony M.
    Haemmerich, Dieter
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (03): : 300 - 307
  • [27] Is lessmore? Impact of different ablation protocols on periprocedural complications in second-generation cryoballoon based pulmonary vein isolation
    Rottner, Laura
    Fink, Thomas
    Heeger, Christian-Hendrik
    Schlueter, Michael
    Goldmann, Britta
    Lemes, Christine
    Maurer, Tilman
    Reissmann, Bruno
    Rexha, Enida
    Riedl, Johannes
    Santoro, Francesco
    Wohlmuth, Peter
    Mathew, Shibu
    Sohns, Christian
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Metzner, Andreas
    [J]. EUROPACE, 2018, 20 (09): : 1459 - 1467
  • [28] Efficacy and safety of circumferential pulmonary vein isolation using a novel cryothermal balloon ablation system
    Sarabanda, AV
    Bunch, TJ
    Johnson, SB
    Mahapatra, S
    Milton, MA
    Leite, LR
    Bruce, GK
    Packer, DL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (10) : 1902 - 1912
  • [29] Acute pyloric spasm and gastric hypomotility - An extracardiac adverse effect of percutaneous radiofrequency ablation for atrial fibrillation
    Shah, D
    Dumonceau, JM
    Burri, H
    Sunthorn, H
    Schroft, A
    Gentil-Baron, P
    Yokoyama, Y
    Takahashi, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (02) : 327 - 330
  • [30] Cryoballoon Pulmonary Vein Isolation Guided by Transesophageal Echocardiography: Novel Aspects on an Emerging Ablation Technique
    Siklody, Claudia Herrera
    Minners, Jan
    Allgeier, Martin
    Allgeier, Hans-Juergen
    Jander, Nikolaus
    Weber, Reinhold
    Schiebeling-Roemer, Jochen
    Neumann, Franz-Josef
    Kalusche, Dietrich
    Arentz, Thomas
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (11) : 1197 - 1202