Comparison of Optic Disc Ovality Index and Rotation Angle Measurements in Myopic Eyes Using Photography and OCT Based Techniques

被引:8
作者
Rezapour, Jasmin [1 ,2 ]
Tran, Andrew Q. [1 ]
Bowd, Christopher [1 ]
El-Nimri, Nevin W. [1 ]
Belghith, Akram [1 ]
Christopher, Mark [1 ]
Brye, Nicole [1 ]
Proudfoot, James A. [1 ]
Dohleman, Jade [1 ]
Fazio, Massimo A. [1 ,3 ,4 ]
Jonas, Jost B. [5 ,6 ]
Weinreb, Robert N. [1 ]
Zangwill, Linda M. [1 ]
机构
[1] Univ Calif San Diego, Shiley Eye Inst, Hamilton Glaucoma Ctr, Viterbi Family Dept Ophthalmol, San Diego, CA 92093 USA
[2] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Ophthalmol, Mainz, Germany
[3] Univ Alabama Birmingham, Sch Med, Dept Ophthalmol, Birmingham, AL USA
[4] Univ Alabama Birmingham, Sch Engn, Dept Biomed Engn, Birmingham, AL USA
[5] Heidelberg Univ, Med Fac Mannheim, Dept Ophthalmol, Mannheim, Germany
[6] Inst Mol & Clin Ophthalmol, Basel, Switzerland
关键词
high myopia; glaucoma; OCT; Bruch's membrane opening; axial myopia; optic nerve head morphology; clinical disc margin; OCT landmarks; NERVE HEAD MORPHOLOGY; COHERENCE TOMOGRAPHY; POPULATION PREVALENCE; GLAUCOMA; TILT; THICKNESS; ASSOCIATION; CRESCENT; LOCATION; CHILDREN;
D O I
10.3389/fmed.2022.872658
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeTo compare optic nerve head (ONH) ovality index and rotation angle measurements based on semi-automated delineation of the clinical ONH margin derived from photographs and automated BMO configuration derived from optical coherence tomography (OCT) images in healthy and glaucomatous eyes with high-, mild- and no axial myopia. MethodsOne hundred seventy-five healthy and glaucomatous eyes of 146 study participants enrolled in the Diagnostic Innovations in Glaucoma Study (DIGS) with optic disc photographs and Spectralis OCT ONH scans acquired on the same day were stratified by level of axial myopia (non-myopic [n = 56, axial length (AL) <24 mm], mild-myopic [n = 58, AL 24-26 mm] and high-myopic [n = 32, AL >26 mm]. The clinical disc margin of each photograph was manually annotated, and semi-automated measurements were recorded of the ovality index and rotation angle based on a best-fit ellipse generated using ImageJ software. These semi-automated photograph-based measurements were compared to ovality index and rotation angle generated from custom automated BMO-based analysis using segmented OCT ONH volumes. R-2 values from linear mixed effects models were used to describe the associations between semi-automated, photograph-based and automated OCT-based measurements. ResultsAverage (95% CI) axial length was 23.3 (23.0, 23.3) mm, 24.8 (24.7, 25.0) mm and 26.8 (26.6, 27.0) mm in non-myopic, mild-myopic and high-myopic eyes, respectively (ANOVA, p <= 0.001 for all). The R-2 association (95% CI) between semi-automated photograph-based and automated OCT-based assessment of ONH OI for all eyes was [0.26 (0.16, 0.36); p < 0.001]. This association was weakest in non-myopic eyes [0.09 (0.01, 0.26); p = 0.02], followed by mild-myopic eyes [0.13 (0.02, 0.29); p = 0.004] and strongest in high-myopic eyes [0.40 (0.19, 0.60); p < 0.001]. No significant associations were found between photography- and OCT-based assessment of rotation angle with R-2 values ranging from 0.00 (0.00, 0.08) in non-myopic eyes to 0.03 (0.00, 0.21) in high-myopic eyes (all associations p >= 0.33). ConclusionsAgreement between photograph-based and automated OCT-based ONH morphology measurements is limited, suggesting that these methods cannot be used interchangeably for characterizing myopic changes in the ONH.
引用
收藏
页数:11
相关论文
共 44 条
  • [11] Optic Disc Ovality in Primary School Children in Beijing
    Guo, Yin
    Liu, Li Juan
    Xu, Liang
    Lv, Yan Yun
    Tang, Ping
    Feng, Yi
    Zhou, Jin Qiong
    Meng, Meng
    Jonas, Jost B.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (08) : 4547 - 4553
  • [12] Global Prevalence of Myopia and High Myopia and Temporal Trends from 2000 through 2050
    Holden, Brien A.
    Fricke, Timothy R.
    Wilson, David A.
    Jong, Monica
    Naidoo, Kovin S.
    Sankaridurg, Padmaja
    Wong, Tien Y.
    Naduvilath, Thomas J.
    Resnikoff, Serge
    [J]. OPHTHALMOLOGY, 2016, 123 (05) : 1036 - 1042
  • [13] Measurement of the Optic Disc Vertical Tilt Angle With Spectral-Domain Optical Coherence Tomography and Influencing Factors
    Hosseini, Hamid
    Nassiri, Nariman
    Azarbod, Parham
    Giaconi, Joann
    Chou, Tom
    Caprioli, Joseph
    Nouri-Mahdavi, Kouros
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (04) : 737 - 744
  • [14] Population Prevalence of Tilted and Torted Optic Discs Among an Adult Chinese Population in Singapore
    How, Alicia C. S.
    Tan, Gavin S. W.
    Chan, Yiong-Huak
    Wong, Tina T. L.
    Seah, Steve K.
    Foster, Paul J.
    Aung, Tin
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (07) : 894 - 899
  • [15] Myopia and glaucoma: sorting out the difference
    Hsu, Chi-Hsin
    Chen, Rebecca I.
    Lin, Shan C.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2015, 26 (02) : 90 - 95
  • [16] Characteristics of Peripapillary Retinal Nerve Fiber Layer Thickness in Eyes With Myopic Optic Disc Tilt and Rotation
    Hwang, Young Hoon
    Yoo, Chungkwon
    Kim, Yong Yeon
    [J]. JOURNAL OF GLAUCOMA, 2012, 21 (06) : 394 - 400
  • [17] Myopic Optic Disc Tilt and the Characteristics of Peripapillary Retinal Nerve Fiber Layer Thickness Measured by Spectral-domain Optical Coherence Tomography
    Hwang, Young Hoon
    Yoo, Chungkwon
    Kim, Yong Yeon
    [J]. JOURNAL OF GLAUCOMA, 2012, 21 (04) : 260 - 265
  • [18] Optical Coherence Tomography Optic Nerve Head Morphology in Myopia I: Implications of Anterior Scleral Canal Opening Versus Bruch Membrane Opening Offset
    Jeoung, Jin Wook
    Yang, Hongli
    Gardiner, Stuart
    Wang, Ya Xing
    Hong, Seungwoo
    Fortune, Brad
    Girard, Michael J. A.
    Hardin, Christy
    Wei, Ping
    Nicolela, Marcelo
    Vianna, Jayme R.
    Chauhan, Balwantray C.
    Burgoyne, Claude F.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 218 : 105 - 119
  • [19] Parapapillary Gamma Zone and Axial Elongation-Associated Optic Disc Rotation: The Beijing Eye Study
    Jonas, Jost B.
    Wang, Ya Xing
    Zhang, Qi
    Fan, Yuan Yuan
    Xu, Liang
    Wei, Wen Bin
    Jonas, Rahul A.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (02) : 396 - 402
  • [20] Prevalence of Myopia and its Association with Body Stature and Educational Level in 19-Year-Old Male Conscripts in Seoul, South Korea
    Jung, Su-Kyung
    Lee, Jin Hae
    Kakizaki, Hirohiko
    Jee, Donghyun
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (09) : 5579 - 5583