Comparison of Optic Disc Ovality Index and Rotation Angle Measurements in Myopic Eyes Using Photography and OCT Based Techniques

被引:8
作者
Rezapour, Jasmin [1 ,2 ]
Tran, Andrew Q. [1 ]
Bowd, Christopher [1 ]
El-Nimri, Nevin W. [1 ]
Belghith, Akram [1 ]
Christopher, Mark [1 ]
Brye, Nicole [1 ]
Proudfoot, James A. [1 ]
Dohleman, Jade [1 ]
Fazio, Massimo A. [1 ,3 ,4 ]
Jonas, Jost B. [5 ,6 ]
Weinreb, Robert N. [1 ]
Zangwill, Linda M. [1 ]
机构
[1] Univ Calif San Diego, Shiley Eye Inst, Hamilton Glaucoma Ctr, Viterbi Family Dept Ophthalmol, San Diego, CA 92093 USA
[2] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Ophthalmol, Mainz, Germany
[3] Univ Alabama Birmingham, Sch Med, Dept Ophthalmol, Birmingham, AL USA
[4] Univ Alabama Birmingham, Sch Engn, Dept Biomed Engn, Birmingham, AL USA
[5] Heidelberg Univ, Med Fac Mannheim, Dept Ophthalmol, Mannheim, Germany
[6] Inst Mol & Clin Ophthalmol, Basel, Switzerland
关键词
high myopia; glaucoma; OCT; Bruch's membrane opening; axial myopia; optic nerve head morphology; clinical disc margin; OCT landmarks; NERVE HEAD MORPHOLOGY; COHERENCE TOMOGRAPHY; POPULATION PREVALENCE; GLAUCOMA; TILT; THICKNESS; ASSOCIATION; CRESCENT; LOCATION; CHILDREN;
D O I
10.3389/fmed.2022.872658
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeTo compare optic nerve head (ONH) ovality index and rotation angle measurements based on semi-automated delineation of the clinical ONH margin derived from photographs and automated BMO configuration derived from optical coherence tomography (OCT) images in healthy and glaucomatous eyes with high-, mild- and no axial myopia. MethodsOne hundred seventy-five healthy and glaucomatous eyes of 146 study participants enrolled in the Diagnostic Innovations in Glaucoma Study (DIGS) with optic disc photographs and Spectralis OCT ONH scans acquired on the same day were stratified by level of axial myopia (non-myopic [n = 56, axial length (AL) <24 mm], mild-myopic [n = 58, AL 24-26 mm] and high-myopic [n = 32, AL >26 mm]. The clinical disc margin of each photograph was manually annotated, and semi-automated measurements were recorded of the ovality index and rotation angle based on a best-fit ellipse generated using ImageJ software. These semi-automated photograph-based measurements were compared to ovality index and rotation angle generated from custom automated BMO-based analysis using segmented OCT ONH volumes. R-2 values from linear mixed effects models were used to describe the associations between semi-automated, photograph-based and automated OCT-based measurements. ResultsAverage (95% CI) axial length was 23.3 (23.0, 23.3) mm, 24.8 (24.7, 25.0) mm and 26.8 (26.6, 27.0) mm in non-myopic, mild-myopic and high-myopic eyes, respectively (ANOVA, p <= 0.001 for all). The R-2 association (95% CI) between semi-automated photograph-based and automated OCT-based assessment of ONH OI for all eyes was [0.26 (0.16, 0.36); p < 0.001]. This association was weakest in non-myopic eyes [0.09 (0.01, 0.26); p = 0.02], followed by mild-myopic eyes [0.13 (0.02, 0.29); p = 0.004] and strongest in high-myopic eyes [0.40 (0.19, 0.60); p < 0.001]. No significant associations were found between photography- and OCT-based assessment of rotation angle with R-2 values ranging from 0.00 (0.00, 0.08) in non-myopic eyes to 0.03 (0.00, 0.21) in high-myopic eyes (all associations p >= 0.33). ConclusionsAgreement between photograph-based and automated OCT-based ONH morphology measurements is limited, suggesting that these methods cannot be used interchangeably for characterizing myopic changes in the ONH.
引用
收藏
页数:11
相关论文
共 44 条
  • [1] Does the Location of Bruch's Membrane Opening Change Over Time? Longitudinal Analysis Using San Diego Automated Layer Segmentation Algorithm (SALSA)
    Belghith, Akram
    Bowd, Christopher
    Medeiros, Felipe A.
    Hammel, Naama
    Yang, Zhiyong
    Weinreb, Robert N.
    Zangwill, Linda M.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (02) : 675 - 682
  • [2] Belghith A, 2014, IEEE ENG MED BIO, P3869, DOI 10.1109/EMBC.2014.6944468
  • [3] Enhanced Detection of Open-angle Glaucoma with an Anatomically Accurate Optical Coherence Tomography-Derived Neuroretinal Rim Parameter
    Chauhan, Balwantray C.
    O'Leary, Neil
    AlMobarak, Faisal A.
    Reis, Alexandre S. C.
    Yang, Hongli
    Sharpe, Glen P.
    Hutchison, Donna M.
    Nicolela, Marcelo T.
    Burgoyne, Claude F.
    [J]. OPHTHALMOLOGY, 2013, 120 (03) : 535 - 543
  • [4] Optic Disc Tilt Direction Determines the Location of Initial Glaucomatous Damage
    Choi, Jin A.
    Park, Hae-Young Lopilly
    Shin, Hye-Young
    Park, Chan Kee
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (08) : 4991 - 4998
  • [5] Curtin B J, 1970, Trans Am Ophthalmol Soc, V68, P312
  • [6] Ophthalmoscopic-Perspectively Distorted Optic Disc Diameters and Real Disc Diameters
    Dai, Yi
    Jonas, Jost B.
    Ling, Zhihong
    Sun, Xinghuai
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (12) : 7076 - 7083
  • [7] Horizontal and vertical optic disc rotation. The Beijing Eye Study
    Fan, Yuan Yuan
    Jonas, Jost B.
    Wang, Ya Xing
    Chen, Chang Xi
    Wei, Wen Bin
    [J]. PLOS ONE, 2017, 12 (05):
  • [8] Histologic validation of optical coherence tomography-based three-dimensional morphometric measurements of the human optic nerve head: Methodology and preliminary results
    Fazio, Massimo A.
    Gardiner, Stuart K.
    Bruno, Luigi
    Hubbard, Meredith
    Bianco, Gianfranco
    Karuppanan, Udayakumar
    Kim, Jihee
    El Hamdaoui, Mustapha
    Grytz, Rafael
    Downs, J. Crawford
    Girkin, Christopher A.
    [J]. EXPERIMENTAL EYE RESEARCH, 2021, 205
  • [9] The complex interactions of retinal, optical and environmental factors in myopia aetiology
    Flitcroft, D. I.
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 2012, 31 (06) : 622 - 660
  • [10] Association between morphological characteristics of the optic disc and other anatomical features of the fundus in highly myopic eyes
    Guo, Xiaoxiao
    Chen, Xi
    Li, Min
    Li, Shanshan
    You, Ran
    Wang, Yanling
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (05) : 2329 - 2338