Solid-phase extraction assisted dispersive liquid-liquid microextraction based on solidification of floating organic droplet to determine sildenafil and its analogues in dietary supplements

被引:7
作者
Li, Jing [1 ]
Roh, Si Hun [1 ]
Shaodong, Jia [1 ]
Hong, Ji Yeon [1 ]
Lee, Dong-Kyu [1 ]
Shin, Byong-kyu [1 ]
Park, Jeong Hill [1 ,2 ,3 ]
Lee, Jeongmi [4 ]
Kwon, Sung Won [1 ,2 ,5 ]
机构
[1] Seoul Natl Univ, Coll Pharm, 1 Gwanak Ro, Seoul 08826, South Korea
[2] Seoul Natl Univ, Res Inst Pharmaceut Sci, Seoul, South Korea
[3] Ton Duc Thang Univ, Fac Pharm, Ho Chi Minh City, Vietnam
[4] Sungkyunkwan Univ, Sch Pharm, Suwon, South Korea
[5] Seoul Natl Univ, Plant Genom & Breeding Inst, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
adulteration; ion-pairing chromatography; mixed-mode solid-phase extraction; reversed-phase dispersive liquid-liquid microextraction; sildenafil; TANDEM MASS-SPECTROMETRY; ERECTILE DYSFUNCTION; HUMAN PLASMA; HUMAN URINE; PHOSPHODIESTERASE-5; INHIBITORS; STRUCTURE ELUCIDATION; SEXUAL PERFORMANCE; IONIC LIQUID; CHROMATOGRAPHY; VARDENAFIL;
D O I
10.1002/jssc.201700159
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel analytical method for the simultaneous determination of the concentration of sildenafil and its five analogues in dietary supplements using solid-phase extraction assisted reversed-phase dispersive liquid-liquid microextraction based on solidification of floating organic droplet combined with ion-pairing liquid chromatography with an ultraviolet detector was developed. Parameters that affect extraction efficiency were systematically investigated, including the type of solid-phase extraction cartridge, pH of the extraction environment, and the type and volume of extraction and dispersive solvent. The method linearity was in the range of 5.0-100 ng/mL for sildenafil, homosildenafil, udenafil, benzylsildenafil, and thiosildenafil and 10-100 ng/mL for acetildenafil. The coefficients of determination were = 0.996 for all regression curves. The sensitivity values expressed as limit of detection were between 2.5 and 7.5 ng/mL. Furthermore, intraday and interday precisions expressed as relative standard deviations were less than 5.7 and 9.9%, respectively. The proposed method was successfully applied to the analysis of sildenafil and its five analogues in complex dietary supplements.
引用
收藏
页码:3120 / 3129
页数:10
相关论文
共 42 条
  • [1] Sensitive and rapid HPLC-UV method with back-extraction step for the determination of sildenafil in human plasma
    Al-Hroub, Hamza
    Alkhawaja, Bayan
    Alkhawaja, Eman
    Arafat, Tawfiq
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1009 : 1 - 6
  • [2] Aschenbrenner DS, 2008, AM J NURS, V108, P79
  • [3] High-performance liquid chromatography with diode array detection method for the simultaneous determination of seven selected phosphodiesterase-5 inhibitors and serotonin reuptake inhibitors used as male sexual enhancers
    Baker, Mostafa M.
    Belal, Tarek S.
    Mahrous, Mohamed S.
    Ahmed, Hytham M.
    Daabees, Hoda G.
    [J]. JOURNAL OF SEPARATION SCIENCE, 2016, 39 (09) : 1656 - 1665
  • [4] Analysis of herbal dietary supplements for sexual performance enhancement: First characterization of propoxyphenyl-thiohydroxyhomosildenafil and identification of sildenafil, thiosildenafil, phentolamine and tetrahydropalmatine as adulterants
    Balayssac, Stephane
    Gilard, Veronique
    Zedde, Chantal
    Martino, Robert
    Malet-Martino, Myriam
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 63 : 135 - 150
  • [5] Structure elucidation of sildenafil analogues in herbal products
    Blok-Tip, L
    Zomer, B
    Bakker, F
    Hartog, KD
    Hamzink, M
    ten Hove, J
    Vredenbregt, M
    de Kaste, D
    [J]. FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2004, 21 (08): : 737 - 748
  • [6] BRADBURY RP, 1947, CHEM IND-LONDON, P196
  • [7] Low-density extraction solvent-based solvent terminated dispersive liquid-liquid microextraction combined with gas chromatography-tandem mass spectrometry for the determination of carbamate pesticides in water samples
    Chen, Hao
    Chen, Ruiwen
    Li, Shengqing
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (08) : 1244 - 1248
  • [8] Quantification of free and total bisphenol A and bisphenol B in human urine by dispersive liquid-liquid microextraction (DLLME) and heart-cutting multidimensional gas chromatography-mass spectrometry (MD-GC/MS)
    Cunha, S. C.
    Fernandes, J. O.
    [J]. TALANTA, 2010, 83 (01) : 117 - 125
  • [9] Synthesis of core-shell magnetic molecularly imprinted polymers and detection of sildenafil and vardenafil in herbal dietary supplements
    Ding, Meijuan
    Wu, Xiaoli
    Yuan, Lihua
    Wang, Shu
    Li, Yun
    Wang, Ruoyu
    Wen, Tingting
    Du, Shuhu
    Zhou, Xuemin
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2011, 191 (1-3) : 177 - 183
  • [10] Application of tandem dispersive liquid-liquid microextraction for the determination of doxepin, citalopram, and fluvoxamine in complicated samples
    Fahimirad, Bahareh
    Asghari, Alireza
    Bazregar, Mohammad
    Rajabi, Maryam
    Fahimi, Ebrahim
    [J]. JOURNAL OF SEPARATION SCIENCE, 2016, 39 (24) : 4828 - 4834