Effects of Traction on Interpretation of Lumbar Bone Mineral Density in Patients with Duchenne Muscular Dystrophy: A New Measurement Method and Diagnostic Criteria Based on Comparison of Dual-Energy X-Ray Absorptiometry and Quantitative Computed Tomography

被引:10
作者
Lee, Je-Sang [1 ,2 ]
Kim, Keunyoung [3 ]
Jeon, Yun Kyung [4 ,5 ]
Kim, Jinmi [6 ]
Jung, Hwi [1 ,2 ]
Kim, Sang Hun [1 ,2 ]
Shin, Myung Jun [1 ,2 ]
Shin, Yong Beom [1 ,2 ]
机构
[1] Pusan Natl Univ, Dept Rehabil Med, Sch Med, 179 Gudeok Ro, Busan, South Korea
[2] Pusan Natl Univ Hosp, Biomed Res Inst, 179 Gudeok Ro, Busan, South Korea
[3] Pusan Natl Univ Hosp, Dept Nucl Med & Biomed Res Inst, Busan, South Korea
[4] Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Internal Med, Div Endocrinol,Sch Med, Busan, South Korea
[5] Pusan Natl Univ, Med Res Inst, Busan, South Korea
[6] Pusan Natl Univ Hosp, Clin Trial Ctr, Biomed Res Inst, Dept Biostat, Busan, South Korea
关键词
Bone density; duchenne muscular dystrophy; dual-energy X-ray absorptiometry; scoliosis; quantitative computed tomography; IDIOPATHIC SCOLIOSIS; ROTATION CORRECTION; GENERAL-ANESTHESIA; CURVE FLEXIBILITY; OSTEOPOROSIS; RADIOGRAPHS; STRENGTH; FEMUR; SPINE; PRONE;
D O I
10.1016/j.jocd.2018.07.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: This study aimed to compare the performance of dual-energy X-ray absorptiometry (DXA) and quantitative computed tomography (QCT) in evaluating bone mineral density (BMD) of patients with Duchenne muscular dystrophy and scoliosis. Methodology: Twenty-nine participants (mean age 19.72 +/- 6.13 years) underwent whole spine radiography, DXA before and after traction, and QCT alone without traction. Scoliosis and vertebral rotation angles obtained before and after traction were compared, and BMD values from DXA were compared to those obtained via QCT. The scoliosis angle, presented as Cobb's angle of L1-L4, was measured. Results: Cobb's angle significantly decreased from 30.38 degrees +/- 24.83 degrees before traction to 22.78 degrees +/- 20.41 degrees after traction (p < 0.0001) and the Z-score decreased from -1.88 +/- 1.59 to -2.86 +/- 2.16 (p < 0.0001). Changes in rotation angle, BMD, and bone mineral content were not significant. Post-traction BMD values and Z-scores showed a higher correlation with QCT measurements than pretraction. Moreover, pre and post-traction Z-scores (<= -1.1 and -1.36, respectively) were more accurate in identifying patients with osteoporosis according to QCT scans compared with the preexisting Z-score of -2 or less. Conclusion: Lumbar BMD measured via DXA and scoliosis allowed a more accurate diagnosis of osteoporosis when traction was applied.
引用
收藏
页码:53 / 62
页数:10
相关论文
共 50 条
[41]   Usefulness of quantitative heel ultrasound compared with dual-energy X-ray absorptiometry in determining bone mineral density in chronic haemodialysis patients [J].
Taal, MW ;
Cassidy, MJD ;
Pearson, D ;
Green, D ;
Masud, T .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1999, 14 (08) :1917-1921
[42]   Comparison of computed tomography and dual-energy X-ray absorptiometry in the evaluation of body composition in patients with obesity [J].
Palmas, Fiorella ;
Ciudin, Andreea ;
Guerra, Raul ;
Eiroa, Daniel ;
Espinet, Carina ;
Roson, Nuria ;
Burgos, Rosa ;
Simo, Rafael .
FRONTIERS IN ENDOCRINOLOGY, 2023, 14
[43]   Dual-energy X-ray absorptiometry overestimates bone mineral density of the lumbar spine in persons with spinal cord injury [J].
W A Bauman ;
E Schwartz ;
I S Y Song ;
S Kirshblum ;
C Cirnigliaro ;
N Morrison ;
A M Spungen .
Spinal Cord, 2009, 47 :628-633
[44]   In vivo differences among scan modes in bone mineral density measurement at dual-energy X-ray absorptiometry [J].
Michele Bandirali ;
Luca M. Sconfienza ;
Alberto Aliprandi ;
Giovanni Di Leo ;
Daniele Marchelli ;
Fabio M. Ulivieri ;
Francesco Sardanelli .
La radiologia medica, 2014, 119 :257-260
[45]   Bone mineral density of the mandible in ovariectomized rats: analyses using dual energy X-ray absorptiometry and peripheral quantitative computed tomography [J].
Kuroda, S ;
Mukohyama, H ;
Kondo, H ;
Aoki, K ;
Ohya, K ;
Ohyama, T ;
Kasugai, S .
ORAL DISEASES, 2003, 9 (01) :24-28
[46]   Soft tissue density variations in thalassemia major: a possible pitfall in lumbar bone mineral density measurements by dual-energy X-ray a absorptiometry [J].
Yildiz, M ;
Canatan, D .
PEDIATRIC HEMATOLOGY AND ONCOLOGY, 2005, 22 (08) :723-726
[47]   Relationship of gray values in cone beam computed tomography and bone mineral density obtained by dual energy X-ray absorptiometry [J].
Shokri, Abbas ;
Ghanbari, Mahsa ;
Maleki, Fatemeh Hafez ;
Ramezani, Leila ;
Amini, Payam ;
Tapak, Leili .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2019, 128 (03) :319-331
[48]   Correlation between Bone Mineral Density Measured by Dual-Energy X-Ray Absorptiometry and Hounsfield Units Measured by Diagnostic CT in Lumbar Spine [J].
Lee, Sungjoon ;
Chung, Chun Kee ;
Oh, So Hee ;
Park, Sung Bae .
JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2013, 54 (05) :384-389
[49]   Dual-energy X-ray absorptiometry, peripheral quantitative computed tomography, and micro-computed tomography techniques are discordant for bone density and geometry measurements in the guinea pig [J].
Mak, Ivy L. ;
DeGuire, Jason R. ;
Lavery, Paula ;
Agellon, Sherry ;
Weiler, Hope A. .
JOURNAL OF BONE AND MINERAL METABOLISM, 2016, 34 (03) :266-276
[50]   Inappropriate reference range for peak bone mineral density in dual-energy X-ray absorptiometry:: Implications for the interpretation of T-scores [J].
Gürlek, A ;
Bayraktar, M ;
Ariyürek, M .
OSTEOPOROSIS INTERNATIONAL, 2000, 11 (09) :809-813