Effects of Traction on Interpretation of Lumbar Bone Mineral Density in Patients with Duchenne Muscular Dystrophy: A New Measurement Method and Diagnostic Criteria Based on Comparison of Dual-Energy X-Ray Absorptiometry and Quantitative Computed Tomography

被引:12
|
作者
Lee, Je-Sang [1 ,2 ]
Kim, Keunyoung [3 ]
Jeon, Yun Kyung [4 ,5 ]
Kim, Jinmi [6 ]
Jung, Hwi [1 ,2 ]
Kim, Sang Hun [1 ,2 ]
Shin, Myung Jun [1 ,2 ]
Shin, Yong Beom [1 ,2 ]
机构
[1] Pusan Natl Univ, Dept Rehabil Med, Sch Med, 179 Gudeok Ro, Busan, South Korea
[2] Pusan Natl Univ Hosp, Biomed Res Inst, 179 Gudeok Ro, Busan, South Korea
[3] Pusan Natl Univ Hosp, Dept Nucl Med & Biomed Res Inst, Busan, South Korea
[4] Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Internal Med, Div Endocrinol,Sch Med, Busan, South Korea
[5] Pusan Natl Univ, Med Res Inst, Busan, South Korea
[6] Pusan Natl Univ Hosp, Clin Trial Ctr, Biomed Res Inst, Dept Biostat, Busan, South Korea
关键词
Bone density; duchenne muscular dystrophy; dual-energy X-ray absorptiometry; scoliosis; quantitative computed tomography; IDIOPATHIC SCOLIOSIS; ROTATION CORRECTION; GENERAL-ANESTHESIA; CURVE FLEXIBILITY; OSTEOPOROSIS; RADIOGRAPHS; STRENGTH; FEMUR; SPINE; PRONE;
D O I
10.1016/j.jocd.2018.07.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: This study aimed to compare the performance of dual-energy X-ray absorptiometry (DXA) and quantitative computed tomography (QCT) in evaluating bone mineral density (BMD) of patients with Duchenne muscular dystrophy and scoliosis. Methodology: Twenty-nine participants (mean age 19.72 +/- 6.13 years) underwent whole spine radiography, DXA before and after traction, and QCT alone without traction. Scoliosis and vertebral rotation angles obtained before and after traction were compared, and BMD values from DXA were compared to those obtained via QCT. The scoliosis angle, presented as Cobb's angle of L1-L4, was measured. Results: Cobb's angle significantly decreased from 30.38 degrees +/- 24.83 degrees before traction to 22.78 degrees +/- 20.41 degrees after traction (p < 0.0001) and the Z-score decreased from -1.88 +/- 1.59 to -2.86 +/- 2.16 (p < 0.0001). Changes in rotation angle, BMD, and bone mineral content were not significant. Post-traction BMD values and Z-scores showed a higher correlation with QCT measurements than pretraction. Moreover, pre and post-traction Z-scores (<= -1.1 and -1.36, respectively) were more accurate in identifying patients with osteoporosis according to QCT scans compared with the preexisting Z-score of -2 or less. Conclusion: Lumbar BMD measured via DXA and scoliosis allowed a more accurate diagnosis of osteoporosis when traction was applied.
引用
收藏
页码:53 / 62
页数:10
相关论文
共 50 条
  • [1] EFFECTS OF TRACTION ON INTERPRETATION OF LUMBAR BONE MINERAL DENSITY IN PATIENTS WITH DUCHENNE MUSCULAR DYSTROPHY
    Shin, Yong Beom
    Lee, Je-Sang
    MUSCLE & NERVE, 2018, 58 : S41 - S41
  • [2] Evaluation of bone mineral density of the lumbar spine in patients with β-thalassemia major with dual-energy X-ray absorptiometry and quantitative computed tomography -: A comparison study
    Angelopoulos, NG
    Katounda, E
    Rombopoulos, G
    Goula, A
    Kaltzidou, V
    Kaltsas, D
    Ioannis, P
    Tolis, G
    JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2006, 28 (02) : 73 - 78
  • [3] Comparison of Lumbar Spine Bone Mineral Density Using Quantitative Computed Tomography and Dual-Energy X-Ray Absorptiometry in an Ovine Model of Osteoporosis
    Bisazza, Katie
    Nelson, Brad
    Sikes, Katie
    Stewart, Holly
    Easley, Jeremiah
    JOURNAL OF BONE AND MINERAL RESEARCH, 2023, 38 : 167 - 168
  • [4] Bone Mineral Density of the Lumbar Spine in Ambulatory Children with Cerebral Palsy by Dual-Energy X-ray Absorptiometry and Quantitative Computed Tomography
    Wren, Tishya A. L.
    Liang, Adriana
    Bent, Melissa
    Kay, Robert
    JOURNAL OF BONE AND MINERAL RESEARCH, 2024, 39 : 317 - 317
  • [5] Evaluation of bone mineral density of the lumbar spine in patients with beta-thalassemia major with dual-energy X-ray absorptiometry and quantitative computed tomography: A comparison study
    Angelopoulos, N. G.
    Goula, A.
    Rombopoulos, G.
    Kaltzidou, V
    Katounda, E.
    Tolis, G.
    OSTEOPOROSIS INTERNATIONAL, 2006, 17 : S318 - S318
  • [6] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18
  • [7] Comparison of dual-energy X-ray absorptiometry and peripheral quantitative computed tomography for bone mineral density analysis in the cynomolgus monkey.
    Niehoff, M
    Mohr, S
    Weinbauer, GF
    TOXICOLOGICAL SCIENCES, 2003, 72 : 129 - 129
  • [8] Comparison Between Quantitative Computed Tomography-Based Bone Mineral Density Values and Dual-Energy X-Ray Absorptiometry-Based Parameters of Bone Density and Microarchitecture: A Lumbar Spine Study
    Fusco, Stefano
    Spadafora, Pierino
    Gallazzi, Enrico
    Ghiara, Carlotta
    Albano, Domenico
    Sconfienza, Luca Maria
    Messina, Carmelo
    APPLIED SCIENCES-BASEL, 2025, 15 (06):
  • [9] A Comparison of Dual-energy X-ray Absorptiometry and Lumbar Computed Tomography Hounsfield Units
    Aynaszyan, Stephan
    Devia, Luis G.
    Parry, Matthew W.
    Badve, Siddharth
    DelSole, Edward M.
    CLINICAL SPINE SURGERY, 2023, 36 (08): : E369 - E374
  • [10] Vertebral bone density evaluated by dual-energy x-ray absorptiometry and quantitative computed tomography in vitro
    Ebbesen, EN
    Thomsen, JS
    Beck-Nielsen, H
    Nepper-Rasmussen, HJ
    Mosekilde, L
    BONE, 1998, 23 (03) : 283 - 290