Ocular Pulse Elastography: Imaging Corneal Biomechanical Responses to Simulated Ocular Pulse Using Ultrasound

被引:19
作者
Clayson, Keyton [1 ,2 ]
Pavlatos, Elias [1 ]
Pan, Xueliang [3 ]
Sandwisch, Thomas [1 ]
Ma, Yanhui [1 ]
Liu, Jun [1 ,2 ,4 ]
机构
[1] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[2] Ohio State Univ, Biophys Interdisciplinary Grp, Columbus, OH 43210 USA
[3] Ohio State Univ, Dept Biomed Informat, Columbus, OH 43210 USA
[4] Ohio State Univ, Dept Ophthalmol & Visual Sci, Columbus, OH 43210 USA
关键词
corneal biomechanical properties; intraocular pressure; ocular pulse; corneal crosslinking; high frequency ultrasound elastography; COLLAGEN CROSS-LINKING; INTRAOCULAR-PRESSURE; EX-VIVO; ELASTICITY; KERATOCONUS; THICKNESS; STRAIN; PARAMETERS; BEHAVIOR; IMPACT;
D O I
10.1167/tvst.9.1.5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: In vivo evaluation of corneal biomechanics holds the potential for improving diagnosis and management of ocular diseases. We aimed to develop an ocular pulse elastography (OPE) technique to quantify corneal strains generated by naturally occurring pulsations of the intraocular pressure (IOP) using high-frequency ultrasound. Methods: Simulated ocular pulses were induced in whole porcine and human donor globes to investigate the effects of physiologic variations in baseline IOP, ocular pulse amplitude, and frequency on corneal strains. Ocular pulse-induced strains were measured in additional globes before and after UVA-riboflavin-induced corneal crosslinking. The central cornea in each eye was imaged with a 50-MHz ultrasound imaging system and correlation-based speckle tracking of radiofrequency data was used to calculate tissue displacements and strains. Results: Ocular pulse-induced corneal strains followed the cyclic changes of IOP. Both baseline IOP and ocular pulse amplitude had a significant influence on strain magnitude. Variations in pulse frequency within the normal human heart rate range did not introduce detectable changes in corneal strains. A significant decrease of corneal strain, as quantified by the OPE technique, was observed after corneal crosslinking. The extent of corneal stiffening (i.e., strain reduction) seemed to correlate with the initial strain magnitude. Conclusions: This ex vivo study demonstrated the feasibility of the OPE method to quantify corneal strains generated by IOP pulsation and detect changes associated with corneal crosslinking treatment. Translational Relevance: Integrating in vivo measurement of IOP and ocular pulse amplitude, the OPE method may lead to a new clinical tool for safe and quick biomechanical evaluations of the cornea.
引用
收藏
页数:11
相关论文
共 60 条
[41]   Ultrasonic Microelastography to Assess Biomechanical Properties of the Cornea [J].
Qian, Xuejun ;
Ma, Teng ;
Shih, Cho-Chiang ;
Heur, Martin ;
Zhang, Jun ;
Shung, Koping Kirk ;
Varma, Rohit ;
Humayun, Mark S. ;
Zhou, Qifa .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (03) :647-655
[42]  
Randleman JB, 2008, OPHTHALMOLOGY, V115
[43]   Comparison of Corneal Epithelial Thickness Measurement Between Fourier-Domain OCT and Very High-Frequency Digital Ultrasound [J].
Reinstein, Dan Z. ;
Yap, Timothy E. ;
Archer, Timothy J. ;
Gobbe, Marine ;
Silverman, Ronald H. .
JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (07) :438-U81
[44]   In-vivo corneal pulsation in relation to in-vivo intraocular pressure and corneal biomechanics assessed in-vitro. An animal pilot study [J].
Rogala, Maja M. ;
Danielewska, Monika E. ;
Antonczyk, Agnieszka ;
Kielbowicz, Zdzislaw ;
Rogowska, Marta E. ;
Kozun, Marta ;
Detyna, Jerzy ;
Iskander, D. Robert .
EXPERIMENTAL EYE RESEARCH, 2017, 162 :27-36
[45]   Intraoperative corneal thickness change and clinical outcomes after corneal collagen crosslinking: Standard crosslinking versus hypotonic riboflavin [J].
Rosenblat, Elan ;
Hersh, Peter S. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04) :596-605
[46]   Corneal Biomechanics and Biomaterials [J].
Ruberti, Jeffrey W. ;
Roy, Abhijit Sinha ;
Roberts, Cynthia J. .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 13, 2011, 13 :269-295
[47]   Biomechanical Characterization of Keratoconus Corneas Ex Vivo With Brillouin Microscopy [J].
Scarcelli, Giuliano ;
Besner, Sebastien ;
Pineda, Roberto ;
Yun, Seok Hyun .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (07) :4490-4495
[48]  
Silverman RH, 2001, J ULTRAS MED, V20, P979
[49]   Epithelial Remodeling as Basis for Machine-Based Identification of Keratoconus [J].
Silverman, Ronald H. ;
Urs, Raksha ;
RoyChoudhury, Arindam ;
Archer, Timothy J. ;
Gobbe, Marine ;
Reinstein, Dan Z. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (03) :1580-1587
[50]   Measuring the cornea: the latest developments in corneal topography [J].
Swartz, Tracy ;
Marten, Lisa ;
Wang, Ming .
CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (04) :325-333