Ocular Pulse Elastography: Imaging Corneal Biomechanical Responses to Simulated Ocular Pulse Using Ultrasound

被引:19
作者
Clayson, Keyton [1 ,2 ]
Pavlatos, Elias [1 ]
Pan, Xueliang [3 ]
Sandwisch, Thomas [1 ]
Ma, Yanhui [1 ]
Liu, Jun [1 ,2 ,4 ]
机构
[1] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[2] Ohio State Univ, Biophys Interdisciplinary Grp, Columbus, OH 43210 USA
[3] Ohio State Univ, Dept Biomed Informat, Columbus, OH 43210 USA
[4] Ohio State Univ, Dept Ophthalmol & Visual Sci, Columbus, OH 43210 USA
关键词
corneal biomechanical properties; intraocular pressure; ocular pulse; corneal crosslinking; high frequency ultrasound elastography; COLLAGEN CROSS-LINKING; INTRAOCULAR-PRESSURE; EX-VIVO; ELASTICITY; KERATOCONUS; THICKNESS; STRAIN; PARAMETERS; BEHAVIOR; IMPACT;
D O I
10.1167/tvst.9.1.5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: In vivo evaluation of corneal biomechanics holds the potential for improving diagnosis and management of ocular diseases. We aimed to develop an ocular pulse elastography (OPE) technique to quantify corneal strains generated by naturally occurring pulsations of the intraocular pressure (IOP) using high-frequency ultrasound. Methods: Simulated ocular pulses were induced in whole porcine and human donor globes to investigate the effects of physiologic variations in baseline IOP, ocular pulse amplitude, and frequency on corneal strains. Ocular pulse-induced strains were measured in additional globes before and after UVA-riboflavin-induced corneal crosslinking. The central cornea in each eye was imaged with a 50-MHz ultrasound imaging system and correlation-based speckle tracking of radiofrequency data was used to calculate tissue displacements and strains. Results: Ocular pulse-induced corneal strains followed the cyclic changes of IOP. Both baseline IOP and ocular pulse amplitude had a significant influence on strain magnitude. Variations in pulse frequency within the normal human heart rate range did not introduce detectable changes in corneal strains. A significant decrease of corneal strain, as quantified by the OPE technique, was observed after corneal crosslinking. The extent of corneal stiffening (i.e., strain reduction) seemed to correlate with the initial strain magnitude. Conclusions: This ex vivo study demonstrated the feasibility of the OPE method to quantify corneal strains generated by IOP pulsation and detect changes associated with corneal crosslinking treatment. Translational Relevance: Integrating in vivo measurement of IOP and ocular pulse amplitude, the OPE method may lead to a new clinical tool for safe and quick biomechanical evaluations of the cornea.
引用
收藏
页数:11
相关论文
共 60 条
[11]   3D Characterization of corneal deformation using ultrasound speckle tracking [J].
Clayson, Keyton ;
Pavlatos, Elias ;
Ma, Yanhui ;
Liu, Jun .
JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2017, 10 (06)
[12]   Corneoscleral stiffening increases IOP spike magnitudes during rapid microvolumetric change in the eye [J].
Clayson, Keyton ;
Pan, Xueliang ;
Pavlatos, Elias ;
Short, Ryan ;
Morris, Hugh ;
Hart, Richard T. ;
Liu, Jun .
EXPERIMENTAL EYE RESEARCH, 2017, 165 :29-34
[13]   Intravascular ultrasound elastography: an overview [J].
de Korte, CL ;
van der Steen, AFW .
ULTRASONICS, 2002, 40 (1-8) :859-865
[14]   Morphological and mechanical information of coronary arteries obtained with intravascular elastography - Feasibility study in vivo [J].
de Korte, CL ;
Carlier, SG ;
Mastik, F ;
Doyley, MM ;
van der Steen, AFW ;
Serruys, PW ;
Bom, N .
EUROPEAN HEART JOURNAL, 2002, 23 (05) :405-413
[15]   Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro [J].
de Korte, CL ;
Pasterkamp, G ;
van der Steen, AFW ;
Woutman, HA ;
Bom, N .
CIRCULATION, 2000, 102 (06) :617-623
[16]   Impact of Hydration Media on Ex Vivo Corneal Elasticity Measurements [J].
Dias, Janice ;
Ziebarth, Noel M. .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2015, 41 (05) :281-286
[17]   Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[18]   Comparative study of corneal strip extensometry and inflation tests [J].
Elsheikh, A ;
Anderson, K .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2005, 2 (03) :177-185
[19]   Biomechanical properties of human and porcine corneas [J].
Elsheikh, Ahmed ;
Alhasso, Daad ;
Rama, Paolo .
EXPERIMENTAL EYE RESEARCH, 2008, 86 (05) :783-790
[20]   Experimental assessment of human corneal hysteresis [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Rama, Paolo ;
Campanelli, Marino ;
Garway-Heath, David .
CURRENT EYE RESEARCH, 2008, 33 (03) :205-213