Automatic Deformable MR-Ultrasound Registration for Image-Guided Neurosurgery

被引:66
作者
Rivaz, Hassan [1 ,2 ]
Chen, Sean Jy-Shyang [3 ]
Collins, D. Louis [3 ]
机构
[1] Concordia Univ, Dept Elect & Comp Engn, Montreal, PQ H3G 1M8, Canada
[2] Concordia Univ, PERFORM Ctr, Montreal, PQ H3G 1M8, Canada
[3] McGill Univ, Montreal Neurol Inst, McConnell Brain Imaging Ctr, Montreal, PQ H3A 2B4, Canada
关键词
Brain surgery; IGNS; image guided neurosurgery; intraoperative ultrasound; nonrigid registration; online database; validation database; VESSEL-BASED REGISTRATION; FREEHAND 3D ULTRASOUND; NONRIGID REGISTRATION; MUTUAL-INFORMATION; RIGID REGISTRATION; SIMILARITY MEASURE; VALIDATION; OPTIMIZATION; MAXIMIZATION; FRAMEWORK;
D O I
10.1109/TMI.2014.2354352
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this work, we present a novel algorithm for registration of 3-D volumetric ultrasound (US) and MR using Robust PaTch-based cOrrelation Ratio (RaPTOR). RaPTOR computes local correlation ratio (CR) values on small patches and adds the CR values to form a global cost function. It is therefore invariant to large amounts of spatial intensity inhomogeneity. We also propose a novel outlier suppression technique based on the orientations of the RaPTOR gradients. Our deformation is modeled with free-form cubic B-splines. We analytically derive the derivatives of RaPTOR with respect to the transformation, i.e., the displacement of the B-spline nodes, and optimize RaPTOR using a stochastic gradient descent approach. RaPTORis validated on MR and tracked US images of neurosurgery. Deformable registration of the US and MR images acquired, respectively, preoperation and postresection is of significant clinical significance, but challenging due to, among others, the large amount of missing correspondences between the two images. This work is also novel in that it performs automatic registration of this challenging dataset. To validate the results, we manually locate corresponding anatomical landmarks in the US and MR images of tumor resection in brain surgery. Compared to rigid registration based on the tracking system alone, RaPTOR reduces the mean initial mTRE over 13 patients from 5.9 to 2.9 mm, and the maximum initial TRE from 17.0 to 5.9 mm. Each volumetric registration using RaPTOR takes about 30 sec on a single CPU core. An important challenge in the field of medical image analysis is the shortage of publicly available dataset, which can both facilitate the advancement of new algorithms to clinical settings and provide a benchmark for comparison. To address this problem, we will make our manually located landmarks available online.
引用
收藏
页码:366 / 380
页数:15
相关论文
共 50 条
  • [31] Evaluation of whole-body MR to CT deformable image registration
    Akbarzadeh, A.
    Gutierrez, D.
    Baskin, A.
    Ay, M. R.
    Ahmadian, A.
    Alam, N. Riahi
    Loevblad, K. O.
    Zaidi, H.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 238 - 253
  • [32] Cortical surface registration for image-guided neurosurgery using laser-range scanning
    Miga, MI
    Sinha, TK
    Cash, DM
    Galloway, RL
    Weil, RJ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (08) : 973 - 985
  • [33] Improving target registration accuracy in image-guided neurosurgery by optimizing the distribution of fiducial points
    Wang, Manning
    Song, Zhijian
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (01) : 26 - 31
  • [34] Using cortical vessels for patient registration during image-guided neurosurgery - A phantom study
    Sun, H
    Roberts, DW
    Hartov, A
    Rick, K
    Paulsen, KD
    MEDICAL IMAGING 2003: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2003, 5029 : 183 - 191
  • [35] Multimodal image registration system for image-guided orthopaedic surgery
    Zhang, J.
    Yan, C. H.
    Chui, C. K.
    Ong, S. H.
    Wang, S. C.
    MACHINE VISION AND APPLICATIONS, 2011, 22 (05) : 851 - 863
  • [36] An analysis of tracking error in image-guided neurosurgery
    Ian J. Gerard
    D. Louis Collins
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 1579 - 1588
  • [37] Towards estimating fiducial localization error of point-based registration in image-guided neurosurgery
    Zhi, Deng
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S943 - S949
  • [38] ROBUST SURFACE-MATCHING REGISTRATION BASED ON THE STRUCTURE INFORMATION FOR IMAGE-GUIDED NEUROSURGERY SYSTEM
    Chen, Xinrong
    Yang, Fuming
    Zhang, Ziqun
    Bai, Baodan
    Guo, Lei
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2021, 21 (05)
  • [39] An analysis of tracking error in image-guided neurosurgery
    Gerard, Ian J.
    Collins, D. Louis
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (10) : 1579 - 1588
  • [40] Large Scale Cloud-Based Deformable Registration for Image Guided Therapy
    Mohrehkesh, Shahram
    Fedorov, Andriy
    Vishwanatha, Arun Brahmavar
    Drakopoulos, Fotis
    Kikinis, Ron
    Chrisochoides, Nikos
    2016 IEEE FIRST INTERNATIONAL CONFERENCE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE), 2016, : 67 - 72