Identification of L-3-hydroxybutyrate as an original ketone body in rat serum by column-switching high-performance liquid chromatography and fluorescence derivatization

被引:31
作者
Tsai, YC [1 ]
Liao, TH [1 ]
Lee, JA [1 ]
机构
[1] Taipei Med Univ, Sch Pharm, Dept Pharmaceut Anal, Taipei 110, Taiwan
关键词
L-3-hydroxybutyrate; derivatization; NBD-PZ; enantiomeric separation; cellulose-based chiral column; column-switching HPLC;
D O I
10.1016/S0003-2697(03)00283-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
L-3-Hydroxybutyrate (L-3HB), the enantiorner of D-3-hydroxybutyrate (D-3HB), has traditionally been regarded the "unnatural" ketone body in mammals, although there is suspicion that it is a more-favorable energy fuel for mammalian tissues than D-3HB. In this study, we demonstrated that L-3HB is an original substance in rat serum by applying fluorescence derivatization and a column-switching high-performance liquid chromatography system as the analysis technique. Racemic 3HB in rat serum derivatized using 4-nitro-7-piperazino-2,1,3-benzoxadiazole was first separated by an ODS column and was further confirmed by verifying the disappearance of the racemic 3HB peak after pretreating rat serum with D-3-hydroxybutyryl dehydrogenase. A switching valve was used to simultaneously introduce isolated racemic 3HB to the enantiomeric separation by two CHIRALCEL OD-RH columns connected in tandem. An L isomer was found to accompany the D isomer, which were quantified to be 3.98 muM (3.61%) and 106.20 muM (96.39%), respectively. Using the present analytical method, the dubious interpretation of the existence of L-3HB was clarified. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:34 / 41
页数:8
相关论文
共 31 条
  • [1] Simple determination of azasetron in rat plasma by column-switching high-performance liquid chromatography
    Um, So Young
    Chae, Song Wha
    Park, Hyun Joo
    Chung, Myeon Woo
    Choi, Sun Ok
    Lee, Hwa Jeong
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (23-24) : 3638 - 3643
  • [2] Determination of Biogenic Amines in Fish Meat and Fermented Foods Using Column-Switching High-Performance Liquid Chromatography with Fluorescence Detection
    Ishimaru, Mami
    Muto, Yuma
    Nakayama, Akari
    Hatate, Hideo
    Tanaka, Ryusuke
    FOOD ANALYTICAL METHODS, 2019, 12 (01) : 166 - 175
  • [3] Fluorimetric determination of D-lactate in urine of normal and diabetic rats by column-switching high-performance liquid chromatography
    Lee, JA
    Tsai, YC
    Chen, HY
    Wang, CC
    Chen, SM
    Fukushima, T
    Imai, K
    ANALYTICA CHIMICA ACTA, 2005, 534 (02) : 185 - 191
  • [4] Column-switching high-performance liquid chromatography-fluorescence detection method for malic acid enantiomers in commercial wines
    Onozato, Mayu
    Kanda, Ryuji
    Sato, Yushi
    Sakamoto, Tatsuya
    Umino, Maho
    Fukushima, Takeshi
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2022, 106
  • [5] Determination of Biogenic Amines in Fish Meat and Fermented Foods Using Column-Switching High-Performance Liquid Chromatography with Fluorescence Detection
    Mami Ishimaru
    Yuma Muto
    Akari Nakayama
    Hideo Hatate
    Ryusuke Tanaka
    Food Analytical Methods, 2019, 12 : 166 - 175
  • [6] Designing a Column-Switching High-Performance Liquid Chromatograph System for Enantiomeric Separation of Mouse Urinary D,L-Lactate
    Chen, Chien-Ming
    Yen, Chi-Fu
    BIO-SCIENCE AND BIO-TECHNOLOGY, 2009, 57 : 69 - 75
  • [7] Determination of biogenic amines in wines by high-performance liquid chromatography with on-column fluorescence derivatization
    Busto, O
    Miracle, M
    Guasch, J
    Borrull, F
    JOURNAL OF CHROMATOGRAPHY A, 1997, 757 (1-2) : 311 - 318
  • [8] Determination of rat blood S-D-lactoylglutathione by a column-switching high-performance liquid chromatography with precolumn fluorescence derivatization with 4-fluoro-7-nitro-2,1,3-benzoxadiazole
    Uchino, E
    Fukushima, T
    Tsunoda, M
    Santa, T
    Imai, K
    ANALYTICAL BIOCHEMISTRY, 2004, 330 (02) : 186 - 192
  • [9] Automated column-switching high-performance liquid chromatography system for quantifying N-methyl-D- and -L-aspartate
    Sekine, M
    Fukuda, H
    Nimura, N
    Furuchi, T
    Homma, H
    ANALYTICAL BIOCHEMISTRY, 2002, 310 (01) : 114 - 121
  • [10] Stereoselective determination of unchanged and glucuroconjugated eliprodil, a new anti-ischaemic drug, in human plasma and urine by precolumn derivatization and column-switching high-performance liquid chromatography with fluorescence detection
    Malavasi, B
    Ripamonti, M
    Rouchouse, A
    Ascalone, V
    JOURNAL OF CHROMATOGRAPHY A, 1996, 729 (1-2) : 323 - 333