Effect of intravenous gadolinium-DTPA on diffusion-weighted magnetic resonance images for evaluation of focal hepatic lesions

被引:53
作者
Chiu, FY
Jao, JC
Chen, CY
Liu, GC
Jaw, TS
Chiou, YY
Hsu, FO
Hsu, JS
机构
[1] Kaohsiung Med Univ, Dept Med Imaging, Chung Ho Mem Hosp, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ, Grad Inst Med, Kaohsiung, Taiwan
[3] Kaohsiung Med Univ, Sch Med Radiat Technol, Kaohsiung, Taiwan
关键词
magnetic resonance imaging; apparent diffusion coefficient; diffusion-weighted imaging; hepatic lesions; gadolinium-DTPA;
D O I
10.1097/01.rct.0000157472.98277.5c
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Diffusion-weighted imaging (DWI) is usually performed before administration of intravenous contrast agents. Repetition of DWI is occasionally necessary after contrast administration, but the effects of contrast material on DWI and apparent diffusion coefficient (ADC) values in the abdomen have not yet been fully examined. The purpose of this work is to assess whether administration of gadolinium-based contrast material significantly affects DWI and ADC values at the focal hepatic lesions. Methods: The results of DWI at 3.0 T (Signa VH3; GE Medical Systems, Milwaukee, WI) were examined in 20 patients (age range: 33-86 years, mean age = 68 years) who were evaluated by means of a hepatic protocol at our hospital. Among the 20 patients studied, a total of 57 lesions were detected. Diffusion-weighted imaging was obtained using single-shot echo planar imaging with a b value of 500 s/mm(2). Patients were injected with 0.1 mmol/kg gadopentetate dimeglumine. The signal-to-noise ratio (SNR) of the liver and the hepatic lesions was examined, and the contrast-to-noise ratio (CNR) of each lesion was evaluated. In addition, the ADC values calculated from the DWI were compared before and after administration of contrast agent. The statistical significance of differences between precontrast and postcontrast administration was determined by use of a paired t test. Results: The SNR and CNR of the DWI were not significantly different before and after administration of contrast agent. The ADC values tended to decrease after administration of contrast agent for each focal hepatic lesion and the liver, although they did not reach statistical significance. Conclusion: There was no significant difference before and after administration of contrast agent in the SNR or CNR of DWI. This indicates the feasibility of postcontrast DWI as a substitute for an unsuccessful precontrast-enhanced study in clinical practice.
引用
收藏
页码:176 / 180
页数:5
相关论文
共 23 条
  • [1] Diffusion-weighted imaging with navigated interleaved echo-planar imaging and a conventional gradient system
    Bammer, P
    Stollberger, R
    Augustin, M
    Simbrunner, J
    Offenbacher, H
    Kooijman, H
    Ropele, S
    Kapeller, P
    Wach, P
    Ebner, F
    Fazekas, F
    [J]. RADIOLOGY, 1999, 211 (03) : 799 - 806
  • [2] ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    FELMLEE, JP
    GRIMM, RC
    [J]. RADIOLOGY, 1993, 189 (01) : 259 - 264
  • [3] Diffusion-weighted MR imaging of the liver: distinguishing hepatic abscess from cystic or necrotic tumor
    Chan, JHM
    Tsui, EYK
    Luk, SH
    Fung, ASL
    Yuen, MK
    Szeto, ML
    Cheung, YK
    Wong, KPC
    [J]. ABDOMINAL IMAGING, 2001, 26 (02): : 161 - 165
  • [4] Transient decrease in water diffusion observed in human occipital cortex during visual stimulation
    Darquié, A
    Poline, JB
    Poupon, C
    Saint-Jalmes, H
    Le Bihan, D
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2001, 98 (16) : 9391 - 9395
  • [5] Does MD, 1999, MAGNET RESON MED, V41, P236, DOI 10.1002/(SICI)1522-2594(199902)41:2<236::AID-MRM4>3.0.CO
  • [6] 2-3
  • [7] ECHO-PLANAR MR-IMAGING
    EDELMAN, RR
    WIELOPOLSKI, P
    SCHMITT, F
    [J]. RADIOLOGY, 1994, 192 (03) : 600 - 612
  • [8] Diffusion-weighted MR imaging with a single-shot echoplanar sequence: Detection and characterization of focal hepatic lesions
    Ichikawa, T
    Haradome, H
    Hachiya, J
    Nitatori, T
    Araki, T
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 397 - 402
  • [9] Technologic advances in abdominal MR imaging
    Keogan, MT
    Edelman, RR
    [J]. RADIOLOGY, 2001, 220 (02) : 310 - 320
  • [10] Diffusion-weighted single-shot echoplanar MR imaging for liver disease
    Kim, T
    Murakami, T
    Takahashi, S
    Hori, M
    Tsuda, K
    Nakamura, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (02) : 393 - 398