An Easy Wearable Gait Assessment System for Assessing Stroke Patients

被引:1
|
作者
Tseng, Mu-Hsun [1 ]
Chen, Tain-Song [1 ]
Chang, Ya-Ting [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan, Taiwan
来源
2020 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C 2020) | 2021年
关键词
stroke patient; inertial measurement component; wearable device; Android; gait analysis;
D O I
10.1109/IS3C50286.2020.00061
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The aftereffects of stroke are numerous, and about 88% of patients show hemiplegia with different severity after stroke. Patients can improve their condition through long-term rehabilitation. The effectiveness of rehabilitation can be assessed by the gait characteristics between the feet. However, most of today's gait analysis systems can only be carried out in biomechanical laboratories or medical related institutions. It has been proven that the equipment is expensive and takes up a long time and is not suitable for home care applications. A simple rehabilitation assessment system has become an important clinical issue. In this study, two inertial measurement components are respectively fixed on the instep of the two feet, then the acceleration and angular velocity in the inertial component are extracted as the basis for quantifying the gait characteristics. Due to the limitations of the accelerometer and the gyroscope itself, this study allows the two components to be calibrated to each other through the sensor fusion technique, and integrates the algorithms developed in the study to estimate the correct gait characteristics as much as possible. It can be known from the experimental results that for a normal subject with both feet, the symmetrical ratio presented in the gait characteristics of both feet is about 1. For subjects with difficulty walking on one foot, the symmetrical ratio is greater than 1 or less than 1, indicating that any one foot will be significantly different from the other in some gait characteristics. It can be seen from the results that the correlation of gait characteristics between the normal and abnormal gait feet is consistent with the pre-experiment hypothesis.
引用
收藏
页码:209 / 211
页数:3
相关论文
共 50 条
  • [41] Assessment of Agreement Between a New Application to Compute the Wisconsin Gait Score and 3-Dimensional Gait Analysis, and Reliability of the Application in Stroke Patients
    Guzik, Agnieszka
    Wolan-Nieroda, Andzelina
    Druzbicki, Mariusz
    FRONTIERS IN HUMAN NEUROSCIENCE, 2022, 16
  • [42] Reproducibility of gait kinematics and kinetics in chronic stroke patients
    Fotiadou, Styliani
    Aggeloussis, Nikolaos
    Gourgoulis, Vassilios
    Malliou, Paraskevi
    Papanas, Nikolaos
    Giannakou, Erasmia
    Iliopoulos, Ioannis
    Vadikolias, Konstantinos
    Terzoudi, Aikaterini
    Piperidou, Haritomeni
    NEUROREHABILITATION, 2018, 42 (01) : 53 - 61
  • [43] Gait asymmetry in stroke patients with unilateral spatial neglect
    Pasquale Moretta
    Leandro Donisi
    Pietro Balbi
    Giuseppe Cesarelli
    Luigi Trojano
    Giovanni D’Addio
    Medical & Biological Engineering & Computing, 2023, 61 : 651 - 659
  • [44] Validation of a Wearable System for Lower Extremity Assessment
    Zhang, Haohua
    Song, Yang
    Li, Cheng
    Dou, Yong
    Wang, Dacheng
    Wu, Yinyue
    Chen, Xiaoyi
    Liu, Di
    ORTHOPAEDIC SURGERY, 2023, 15 (11) : 2911 - 2917
  • [45] A Pilot Study to Validate a Wearable Inertial Sensor for Gait Assessment in Older Adults with Falls
    Garcia-Villamil, Guillermo
    Neira-Alvarez, Marta
    Huertas-Hoyas, Elisabet
    Ramon-Jimenez, Antonio
    Rodriguez-Sanchez, Cristina
    SENSORS, 2021, 21 (13)
  • [46] Wearable sensors for gait analysis Comparison between a MIMUs system and a gold standard electromechanical system
    Agostini, V.
    Knaflitz, M.
    Antenucci, L.
    Lisco, G.
    Gastaldi, L.
    Tadano, S.
    2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS, 2015, : 146 - 150
  • [47] Unstable gait assessment with a portable analysis system
    Bagalciague, F.
    San Roman, C.
    Arocena, M.
    Suarez, H.
    Ferreira, E.
    Pena, N.
    2014 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) PROCEEDINGS, 2014, : 181 - 185
  • [48] A Wearable Wireless System for Gait Analysis for Early Diagnosis of Alzheimer and Parkinson Disease
    Margiotta, N.
    Avitabile, G.
    Coviello, G.
    2016 5TH INTERNATIONAL CONFERENCE ON ELECTRONIC DEVICES, SYSTEMS AND APPLICATIONS (ICEDSA), 2016,
  • [49] Wearable Non-Invasive Computer Controlled System for Improving of Seniors Gait
    Simsik, Dusan
    Galajdova, Alena
    Drutarovsky, Milos
    Galajda, Pavol
    Pavlov, Peter
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2009, 32 : S35 - S35
  • [50] Clinical Effect Analysis of Wearable Sensor Technology-Based Gait Function Analysis in Post-Transcranial Magnetic Stimulation Stroke Patients
    Wang, Litong
    Wang, Likai
    Wang, Zhan
    Gao, Fei
    Wu, Jingyi
    Tang, Hong
    SENSORS, 2024, 24 (10)