Six months of hybrid closed loop in the real-world: An evaluation of children and young adults using the 670G system

被引:111
作者
Berget, Cari [1 ]
Messer, Laurel H. [1 ]
Vigers, Tim [2 ]
Frohnert, Brigitte I. [1 ]
Pyle, Laura [1 ,2 ]
Wadwa, R. Paul [1 ]
Driscoll, Kimberly A. [1 ,3 ]
Forlenza, Gregory P. [1 ]
机构
[1] Univ Colorado, Sch Med, Barbara Davis Ctr Childhood Diabet, Anschutz Campus, Aurora, CO 80045 USA
[2] Colorado Sch Publ Hlth, Dept Biostat & Informat, Aurora, CO USA
[3] Univ Florida, Dept Clin & Hlth Psychol, Gainesville, FL USA
关键词
pediatrics; artificial pancreas; automated insulin delivery; continuous glucose monitor; INSULIN DELIVERY-SYSTEM; QUALITY-OF-LIFE; PROBLEM AREAS; TYPE-1; ADOLESCENTS;
D O I
10.1111/pedi.12962
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To describe glycemic and psychosocial outcomes in youth with type 1 diabetes using a hybrid closed loop (HCL) system. Subjects Youth with type 1 diabetes (2-25 years) starting the 670G HCL system for their diabetes care were enrolled in an observational study. Methods Prospective data collection occurred during routine clinical care and included glycemic variables (sensor time in range [70-180 mg/dL], HbA1c), and psychosocial variables (Hypoglycemia Fear Survey [HFS]; Problem Areas in Diabetes [PAID]). Mixed models were used to analyze change across time. Results Ninety-two youth (mean age 15.7 +/- 3.6 years, 50% female, HbA1c 8.8% +/- 1.8%) started HCL for their diabetes care. Youth used Auto Mode 65.5% +/- 3.0% of the time at month 1, which decreased to 51.2% +/- 3.4% at month 6 (P = .001). Sensor time in range increased from 50.7% +/- 1.8% at baseline to 56.9% +/- 2.1% at 6 months (P = .007). HbA1c decreased from 8.7% +/- 0.2% at baseline to 8.4% +/- 0.2% after 6 months of use (P <= .0001), with the greatest HbA1c decline in participants with high baseline HbA1c. Increased percent time in auto mode was associated with lower HbA1c (P = .02). Thirty percent of youth discontinued HCL in the first 6 months of use. There were no changes in the HFS or PAID scores across time. Conclusions HCL use is associated with improved glycemic control and no change in psychosocial outcomes in this clinical sample. The decline in HCL use across time suggests that youth experience barriers in sustaining use of HCL. Further research is needed to understand reasons for HCL discontinuation and determine intervention strategies.
引用
收藏
页码:310 / 318
页数:9
相关论文
共 33 条
  • [1] Closing the loop overnight at home setting: psychosocial impact for adolescents with type 1 diabetes and their parents
    Barnard, Katharine D.
    Wysocki, Tim
    Allen, Janet M.
    Elleri, Daniela
    Thabit, Hood
    Leelarathna, Lalantha
    Gulati, Arti
    Nodale, Marianna
    Dunger, David B.
    Tinati, Tannaze
    Hovorka, Roman
    [J]. BMJ OPEN DIABETES RESEARCH & CARE, 2014, 2 (01):
  • [2] Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes
    Bergenstal, Richard M.
    Garg, Satish
    Weinzimer, Stuart A.
    Buckingham, Bruce A.
    Bode, Bruce W.
    Tamborlane, William V.
    Kaufman, Francine R.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (13): : 1407 - 1408
  • [3] Hemoglobin A1c (HbA1c) changes over time among adolescent and young adult participants in the T1D exchange clinic registry
    Clements, Mark A.
    Foster, Nicole C.
    Maahs, David M.
    Schatz, Desmond A.
    Olson, Beth A.
    Tsalikian, Eva
    Lee, Joyce M.
    Burt-Solorzano, Christine M.
    Tamborlane, William V.
    Chen, Vincent
    Miller, Kellee M.
    Beck, Roy W.
    [J]. PEDIATRIC DIABETES, 2016, 17 (05) : 327 - 336
  • [4] Psychiatric disorders during early adulthood in those with childhood onset type 1 diabetes: Rates and clinical risk factors from population-based follow-up
    Cooper, M. N.
    Lin, A.
    Alvares, G. A.
    De Klerk, N. H.
    Jones, T. W.
    Davis, E. A.
    [J]. PEDIATRIC DIABETES, 2017, 18 (07) : 599 - 606
  • [5] International Consensus on Use of Continuous Glucose Monitoring
    Danne, Thomas
    Nimri, Revital
    Battelino, Tadej
    Bergenstal, Richard M.
    Close, Kelly L.
    DeVries, J. Hans
    Garg, Satish
    Heinemann, Lutz
    Hirsch, Irl
    Amiel, Stephanie A.
    Beck, Roy
    Bosi, Emanuele
    Buckingham, Bruce
    Cobelli, Claudio
    Dassau, Eyal
    Doyle, Francis J., III
    Heller, Simon
    Hovorka, Roman
    Jia, Weiping
    Jones, Tim
    Kordonouri, Olga
    Kovatchev, Boris
    Kowalski, Aaron
    Laffel, Lori
    Maahs, David
    Murphy, Helen R.
    Norgaard, Kirsten
    Parkin, Christopher G.
    Renard, Eric
    Saboo, Banshi
    Scharf, Mauro
    Tamborlane, William V.
    Weinzimer, Stuart A.
    Phillip, Moshe
    [J]. DIABETES CARE, 2017, 40 (12) : 1631 - 1640
  • [7] Psychosocial impacts of hybrid closed-loop systems in the management of diabetes: a review
    Farrington, C.
    [J]. DIABETIC MEDICINE, 2018, 35 (04) : 436 - 449
  • [8] REAL-WORLD IMPLICATIONS OF HYBRID CLOSE LOOP (HCL) INSULIN DELIVERY SYSTEM
    Faulds, Eileen R.
    Zappe, Janet
    Dungan, Kathleen M.
    [J]. ENDOCRINE PRACTICE, 2019, 25 (05) : 477 - 484
  • [9] Factory-Calibrated Continuous Glucose Monitoring: How and Why It Works, and the Dangers of Reuse Beyond Approved Duration of Wear
    Forlenza, Gregory P.
    Kushner, Taisa
    Messer, Laurel H.
    Wadwa, R. Paul
    Sankaranarayanan, Sriram
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (04) : 222 - 229
  • [10] Safety Evaluation of the MiniMed 670G System in Children 7-13 Years of Age with Type 1 Diabetes
    Forlenza, Gregory P.
    Pinhas-Hamiel, Orit
    Liljenquist, David R.
    Shulman, Dorothy I.
    Bailey, Timothy S.
    Bode, Bruce W.
    Wood, Michael A.
    Buckingham, Bruce A.
    Kaiserman, Kevin B.
    Shin, John
    Huang, Suiying
    Lee, Scott W.
    Kaufman, Francine R.