An Experimental Comparison of Two Different Clinically Used Implant Designs and Surfaces

被引:39
作者
Gottlow, Jan [1 ]
Barkamo, Sargon [1 ]
Sennerby, Lars [2 ]
机构
[1] Gothenburg Univ, Dept Biomat, Inst Surg Sci, Sahlgrenska Acad, SE-40530 Gothenburg, Sweden
[2] Gothenburg Univ, Dept Oral & Maxillofacial Surg, Inst Odontol, Sahlgrenska Acad, SE-40530 Gothenburg, Sweden
关键词
anodic oxidation; dental implant; histology; hydrophilicity; removal torque; resonance frequency analysis; titanium; RESONANCE FREQUENCY-ANALYSIS; SUBMERGED TITANIUM IMPLANTS; OXIDIZED IMPLANTS; BONE INTEGRATION; RABBIT TIBIA; DOGS; APPOSITION; IMMEDIATE; DEFECTS;
D O I
10.1111/j.1708-8208.2012.00439.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Various designs of dental implants representing different geometries and surface technologies are commercially available and clinically used in patients. However, data with regard to bone tissue responses and stability for comparison of their biologic performances are rare. Purpose: The aim of the present experimental investigation was to compare the bone tissue responses and implant stability between two commonly used dental implants representing different geometries and surface characteristics. Materials and Methods: A total of 90 dental implants (4.3 mm in diameter, 10 mm long) with an oxidized surface (Replace Select Tapered, TiUnite, Nobel Biocare AB, Gothenburg, Sweden) (OX) and 90 implants (4.1 mm in diameter, 10 mm total length) with a hydrophilic sand-blasted and acid etched surface (Standard Plus, SLActive, Institut Straumann AG, Basel, Switzerland) (HSBA) were placed in the distal femur (n = 1) and tibia (n = 2) of 30 rabbits. The implants were analyzed with implant stability quotient (ISQ) measurements, removal torque (RTQ) and histomorphometry (boneimplant contact, BIC) after 10 days, 3, and 6 weeks. Moreover, RTQ values were corrected for differences in surface area by calculating the shear strength for each implant. Results: RTQ and ISQ measurements showed an increase with time for both implant types. A significantly higher RTQ value was observed for the HSBA implant at 3 weeks (p = .05). A lower ISQ value was seen for HSBA than for OX implants at placement in the tibia (p < 0.001). HSBA implants showed higher shear strength values than OX implants after 3 weeks (p < .001), and 6 weeks (p < .01). The morphometric measurements showed significantly higher BIC for HSBA implants after 10 days (p < .01), similar values after 3 weeks and significantly higher BIC for OX implants after 6 weeks (p < .001). Conclusions: Both HSBA and OX implants were well integrated in bone and showed firm and increased stability from placement to after 6 weeks of healing. The HSBA implant showed more BIC after 10 days and the OX implant more BIC after 6 weeks of healing. The HSBA implant showed significantly higher shear strength after 3 and 6 weeks and higher RTQ values after 3 weeks than the OX implant. The results may be due to differences in surface roughness and hydrophilic properties.
引用
收藏
页码:e204 / e212
页数:9
相关论文
共 33 条
  • [1] Albrektsson T, 2004, INT J PROSTHODONT, V17, P536
  • [2] Astra Tech and Branemark system implants:: a 5-year prospective study of marginal bone reactions
    Åstrand, P
    Engquist, B
    Dahlgren, S
    Gröndahl, K
    Engquist, E
    Feldmann, H
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) : 413 - 420
  • [3] Astrand Per, 2004, Clin Implant Dent Relat Res, V6, P130, DOI 10.1111/j.1708-8208.2004.tb00213.x
  • [4] Bahat O, 2009, INT J ORAL MAX IMPL, V24, P325
  • [5] Early Loading at 21 Days of Non-Submerged Titanium Implants With a Chemically Modified Sandblasted and Acid-Etched Surface: 3-Year Results of a Prospective Study in the Posterior Mandible
    Bornstein, Michael M.
    Wittneben, Julia-Gabriela
    Bragger, Urs
    Buser, Daniel
    [J]. JOURNAL OF PERIODONTOLOGY, 2010, 81 (06) : 809 - 818
  • [6] Oxidized titanium implants in reconstructive jaw surgery
    Brechter, M
    Nilson, H
    Lundgren, S
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 : S83 - S87
  • [7] Early bone tissue responses to turned and oxidized implants in the rabbit tibia
    Burgos, Patricia Miranda
    Rasmusson, Lars
    Meirelles, Luiz
    Sennerby, Lars
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2008, 10 (03) : 181 - 190
  • [8] INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS
    BUSER, D
    SCHENK, RK
    STEINEMANN, S
    FIORELLINI, JP
    FOX, CH
    STICH, H
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07): : 889 - 902
  • [9] Enhanced bone apposition to a chemically modified SLA titanium surface
    Buser, D
    Broggini, N
    Wieland, M
    Schenk, RK
    Denzer, AJ
    Cochran, DL
    Hoffmann, B
    Lussi, A
    Steinemann, SG
    [J]. JOURNAL OF DENTAL RESEARCH, 2004, 83 (07) : 529 - 533
  • [10] Davies John E, 2003, J Dent Educ, V67, P932