13C-methionine breath tests for mitochondrial liver function assessment

被引:0
作者
Candelli, M. [1 ]
Miele, L. [1 ]
Armuzzi, A. [1 ]
Nista, E. C. [1 ]
Pignataro, G. [2 ]
Fini, L. [1 ]
Cazzato, I. A. [1 ]
Zocco, M. A. [1 ]
Bartolozzi, F. [1 ]
Gasbarrini, G. [1 ]
Grieco, A. [1 ]
Gasbarrini, A. [1 ]
机构
[1] Univ Cattolica Sacro Cuore, Dept Internal Med, I-00168 Rome, Italy
[2] Univ Cattolica Sacro Cuore, Emergency Dept, I-00168 Rome, Italy
关键词
methionine; breath test; ethanol; liver;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
C-13-methionine breath test has been proposed as a non-invasive tool for the assessment of human hepatic mithocondrial function. Two methionine breath labeled with C-13 in differents point of his molecular structure have been used for breath test analisys. Aim of this study was to compare two differently C-13-abeled methionines in the evaluation of mitochondrial oxidation in basal conditions and after an acute oxidative stress. 15 healthy male subjects (mean age 30.5 +/- 3.1) received [methyl-C-13]-methionine dissolved in water. Breath samples were taken at baseline and and 10, 20, 30, 45, 60, 75, 90, 105 and 120 minutes after the ingestion of the labeled substrate. Forthy-eight hours later, subjects underwent the same test 30 minutes after ethanol ingestion (0,3 g/kg of body weight). Seven-day later, subjects underwent breath test using (L-methionine-1-(COOH)-C-13) as substrate, in basal condition and after ethanol ingestion. At basal condition, the cumulative percentage of (CO2)-C-13 recovered in breath during the test period (%cum-dose) was higher using L-methionine-1 -(COOH)-C-13 than [methyl-C-13] -methionine (10.25 +/- 1.0 vs 4.07 +/- 0.8; p < 0.01). After ethanol ingestion, % cum dose was significantly decreased at 60 and 120 minutes with both methionines (120 min: 10.25 +/- 1.0 vs 5.03% 1.8; < 0.01 and 4.07 +/- 0.8 vs 2.16% +/- 0.9; p < 0.01, respectively). However, %cum-dose during L-methionine-1 13 C-breath test was significantly lower than that observed during methyl-C-13-methionine breath test (120 minutes: 5.03% 1.8 vs 2.16% 0.9; p < 0.01) In conclusion, breath test based on L-methionine-1-13COOH seems to show a greater reliability when compared to [methyl-13C]-methionine to assess mitochondrial function because a larger amount of labeled carbon that reaches the Krebs' cicle.
引用
收藏
页码:245 / 249
页数:5
相关论文
共 21 条
  • [1] Functional evaluation techniques in mitochondrial disorders
    Argov, Z
    [J]. EUROPEAN NEUROLOGY, 1998, 39 (02) : 65 - 71
  • [2] Non-invasive assessment of human hepatic mitochondrial function through the 13C-methionine breath test
    Armuzzi, A
    Marcoccia, S
    Zocco, MA
    De Lorenzo, A
    Grieco, A
    Tondi, P
    Pola, P
    Gasbarrini, G
    Gasbarrini, A
    [J]. SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2000, 35 (06) : 650 - 653
  • [3] S-adenosyl-L-methionine (SAMe):: from the bench to the bedside -: molecular basis of a pleiotrophic molecule
    Bottiglieri, T
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 2002, 76 (05) : 1151S - 1157S
  • [4] Quantitative evaluation of liver function by the methionine and aminopyrine breath tests in the early stages of liver transplantation
    Di Campli, C
    Angelini, G
    Armuzzi, A
    Nardo, B
    Zocco, MA
    Candelli, M
    Santoliquido, A
    Cavallari, A
    Bernardi, M
    Gasbarrini, A
    [J]. EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2003, 15 (07) : 727 - 732
  • [5] METHIONINE METABOLISM IN MAMMALS
    FINKELSTEIN, JD
    [J]. JOURNAL OF NUTRITIONAL BIOCHEMISTRY, 1990, 1 (05) : 228 - 237
  • [6] Homocysteine
    Finkelstein, JD
    Martin, JJ
    [J]. INTERNATIONAL JOURNAL OF BIOCHEMISTRY & CELL BIOLOGY, 2000, 32 (04) : 385 - 389
  • [7] Geypens B, 1999, J NUCL MED, V40, P1451
  • [8] 13C-Aminopyrine breath test to evaluate severity of disease in patients with chronic hepatitis C virus infection
    Giannini, E
    Fasoli, A
    Chiarbonello, B
    Malfatti, F
    Romagnoli, P
    Botta, F
    Testa, E
    Polegato, S
    Fumagalli, A
    Testa, R
    [J]. ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2002, 16 (04) : 717 - 725
  • [9] Evaluation of liver regeneration using the L-[1-13C]methionine breath test
    Ishii, Y
    Asai, S
    Kohno, T
    Takahashi, Y
    Nagata, T
    Suzuki, S
    Kohno, T
    Iwai, S
    Ishikawa, K
    [J]. JOURNAL OF SURGICAL RESEARCH, 2001, 95 (02) : 195 - 199
  • [10] 13C breath tests:: Visions and realities
    Klein, PD
    [J]. JOURNAL OF NUTRITION, 2001, 131 (05) : 1637S - 1642S