Cavity-enhanced absorption spectroscopy for shocktubes: Design and optimization

被引:14
|
作者
Chao, Xing [1 ,2 ]
Shen, Guofeng [3 ]
Sun, Kai [3 ]
Wang, Zhenhai [1 ,2 ]
Meng, Qinghui [1 ,2 ]
Wang, Shengkai [4 ]
Hanson, Ronald K. [4 ]
机构
[1] Tsinghua Univ, Ctr Combust Energy, Dept Energy & Power Engn, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Minist Educ, Key Lab Thermal Sci & Power Engn, Beijing 100084, Peoples R China
[3] Tongji Univ, Sch Automot Studies, Shanghai 201804, Peoples R China
[4] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
基金
美国国家科学基金会;
关键词
Cavity-enhanced absorption spectroscopy; Shocktube; Optical field; Chemical kinetics; TUBE MEASUREMENT; KINETICS; PATHS;
D O I
10.1016/j.proci.2018.06.230
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cavity-enhanced absorption spectroscopy (CEAS) has generated much interest in shocktube kinetics studies because of its recent success in achieving improved sensitivity and high time resolution with robust optical alignment. While recent progress demonstrated experimental schemes including off-axis scanned-wavelength approach and on-axis ps-pulsed laser approach, that both successfully suppressed the laser-cavity coupling noise, this paper develops a theoretical model to predict the CEAS sensor performance that can be used as a design tool applicable to more generalized cases. The method models the optical field in the cavity based on the decentered Gaussian beam model, from which the cavity transmission spectrum and the laser-cavity coupling noise can be numerically calculated. The simulation results predict sensor performance for different cavity configurations and laser characteristics, including various degrees of laser-cavity mode-matching, laser linewidths, scanning rates, and cavity filling conditions. Simulation with example wavelengths in the ultraviolet, near-infrared, and mid-infrared showed increasing mode-matched beam waist size for increasing wavelengths. An off-axis alignment scheme was found to be capable of suppressing the coupling noise by two orders-of-magnitude at a moderate laser linewidth of 1 GHz. Coupling noise level on the order of le-5 for scanned-wavelength off-axis alignment case with a narrowband mid-infrared laser was obtained by model calculation and agreed with experimental results within acceptable uncertainty range. The developed method can serve to guide future design and optimization of CEAS system in shocktube studies. (C) 2018 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1345 / 1353
页数:9
相关论文
共 50 条
  • [21] Simultaneous cavity-enhanced and cavity ringdown absorption spectroscopy using optical feedback
    Thibault Desbois
    Irène Ventrillard
    Daniele Romanini
    Applied Physics B, 2014, 116 : 195 - 201
  • [22] Optical feedback cavity-enhanced absorption spectroscopy (OF-CEAS) in a ring cavity
    Hamilton, D. J.
    Nix, M. G. D.
    Baran, S. G.
    Hancock, G.
    Orr-Ewing, A. J.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2010, 100 (02): : 233 - 242
  • [23] Incoherent broad-band cavity-enhanced absorption spectroscopy of liquids
    Fiedler, SE
    Hese, A
    Ruth, AA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (02): : 023107 - 1
  • [24] Detection of Sulfur Dioxide by Broadband Cavity-Enhanced Absorption Spectroscopy (BBCEAS)
    Thalman, Ryan
    Bhardwaj, Nitish
    Flowerday, Callum E.
    Hansen, Jaron C.
    SENSORS, 2022, 22 (07)
  • [25] Applications of Supercontinuum Sources: Incoherent Broadband Cavity-Enhanced Absorption Spectroscopy
    Aalto, Antti
    Genty, Goery
    Toivonen, Juha
    Laurila, Toni
    2013 SIXTH RIO DE LA PLATA WORKSHOP ON LASER DYNAMICS AND NONLINEAR PHOTONICS, 2013,
  • [26] Influence of the cavity parameters on the output intensity in incoherent broadband cavity-enhanced absorption spectroscopy
    Fiedler, Sven E.
    Hese, Achim
    Heitmann, Uwe
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (07):
  • [27] Cavity-enhanced on-chip absorption spectroscopy using microring resonators
    Nitkowski, Arthur
    Chen, Long
    Lipson, Michal
    OPTICS EXPRESS, 2008, 16 (16) : 11930 - 11936
  • [28] Finesse and sensitivity gain in cavity-enhanced absorption spectroscopy of biomolecules in solution
    McGarvey, Timothy
    Conjusteau, Andre
    Mabuchi, Hideo
    OPTICS EXPRESS, 2006, 14 (22): : 10441 - 10451
  • [29] UV cavity-enhanced absorption spectroscopy detects 2 ps transients
    不详
    LASER FOCUS WORLD, 2016, 52 (02): : 10 - 10
  • [30] Optical-feedback cavity-enhanced absorption spectroscopy in a linear cavity: model and experiments
    Katherine M. Manfred
    Luca Ciaffoni
    Grant A. D. Ritchie
    Applied Physics B, 2015, 120 : 329 - 339