Some recent developments in reference methodology within the United Kingdom

被引:22
作者
Catterick, T [1 ]
Craston, D [1 ]
King, B [1 ]
Walker, RF [1 ]
Webb, KS [1 ]
机构
[1] Lab Govt Chemist, Teddington TW11 0LY, Middx, England
关键词
metrology; primary methods; reference materials; traceability; isotope dilution mass spectrometry;
D O I
10.1007/s007690050302
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The UK Valid Analytical Measurement Programme has pump-primed developments in chemical metrology, through a major project on reference methodology and reference materials. This paper provides an overview of developments during 1994-1997 and covers work on primary methods for trace inorganic and trace organic analysis, including the use of isotope dilution mass spectrometry: studies of sample pre-treatment including digestion, extraction, and separation aimed at improving this weak link in the traceability chain; prioritisation, production and marketing of both pure substance and matrix reference materials; and international collaboration concerned with interlaboratory comparisons and the development of concepts terminology and systems to underpin the international chemical measurement system. References are given to a number of papers covering specific parts of the programme.
引用
收藏
页码:3 / 13
页数:11
相关论文
共 30 条
[1]   Development of a multi-element hydride generation inductively coupled plasma mass spectrometry procedure for the simultaneous determination of arsenic, antimony and selenium in waters [J].
Bowman, J ;
Fairman, B ;
Catterick, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (03) :313-316
[2]  
Catterick T, 1995, ATOM SPECTROSC, V16, P229
[3]  
CATTERICK T, 1998, IN PRESS J ANAL ATOM
[4]  
DEBIEVRE P, 1992, ANAL P, V31, P377
[5]  
Dube G, 1998, RAPID COMMUN MASS SP, V12, P28, DOI 10.1002/(SICI)1097-0231(19980115)12:1<28::AID-RCM107>3.0.CO
[6]  
2-M
[7]   Reversed-phase ion-pair chromatography with inductively coupled plasma-mass spectrometry detection for the determination of organo-tin compounds in waters [J].
Fairman, B ;
Catterick, T ;
Wheals, B ;
Polinina, E .
JOURNAL OF CHROMATOGRAPHY A, 1997, 758 (01) :85-92
[8]   Simultaneous determination of arsenic, antimony and selenium in aqueous matrices by electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Fairman, B ;
Catterick, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (08) :863-866
[9]  
Harrington C. F., 1997, Spectroscopy Europe, V9, P16
[10]   REDUCTION OF SYSTEMATIC-ERRORS IN QUANTITATIVE-ANALYSIS BY ISOTOPE-DILUTION MASS-SPECTROMETRY (IDMS) - AN ITERATIVE METHOD [J].
HENRION, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (12) :657-658