Progress toward automated metabolic profiling of human serum: Comparison of CPMG and gradient-filtered NMR analytical methods

被引:27
作者
Lucas, LH
Larive, CK
Wilkinson, PS
Huhn, S
机构
[1] Univ Kansas, Dept Chem, Lawrence, KS 66045 USA
[2] Bruke BioSpin Corp, NMR Applicat Lab, Billerica, MA 01821 USA
关键词
metabonomics; NMR spectroscopy of biofluids; T-2; relaxation; diffusion; principal component analysis (PCA); spectral editing;
D O I
10.1016/j.jpba.2004.09.060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The investigation of drug delivery and metabolism requires the analysis of molecules in complicated biological matrices such as human serum. In NMR-based metabonomic analysis, T-2 relaxation editing with a CPMG filter is commonly used to suppress background signals from proteins and other endogenous components. Radio frequency pulse imperfections and incomplete irradiation across the spectral bandwidth can cause phase and baseline distortions in CPMG spectra. These distortions are exacerbated by water suppression techniques. Baseline correction methods included in commercially available data processing software packages may be incapable of producing artifact-free spectra. To increase the analytical precision of metabolic profiling, one NMR spectroscopist may be responsible for manually phasing and baseline correcting hundreds of spectra individually to remove operator-dependent variations, significantly reducing throughput. For metabonomic analysis of human serum, it was observed that the application of a pulsed field gradient filter produced H-1 NMR spectra well suited to automatic phasing routines. Superior baseline characteristics, an increased tolerance to radio frequency pulse imperfections, and improved water suppression were achieved. A concomitant reduction in signal intensity compared with the CPMG method was easily recovered by increasing the number of scans. Principal component analysis (PCA) of spectra, acquired under a variety of experimental conditions, revealed the improved reproducibility and robustness of H-1 NMR pulsed field gradient-filtered metabonomic analyses of serum compared to the CPMG method. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:156 / 163
页数:8
相关论文
共 35 条
[1]   Using pulsed gradient spin echo NMR for chemical mixture analysis: How to obtain optimum results [J].
Antalek, B .
CONCEPTS IN MAGNETIC RESONANCE, 2002, 14 (04) :225-258
[2]  
BIGLER P, 2000, NMR SPECTROSCOPY PRO, P183
[3]   Application of chemometrics to 1H NMR spectroscopic data to investigate a relationship between human serum metabolic profiles and hypertension [J].
Brindle, JT ;
Nicholson, JK ;
Schofield, PM ;
Grainger, DJ ;
Holmes, E .
ANALYST, 2003, 128 (01) :32-36
[4]  
*BRUK AN GMBH, 1997, XWIN NMR SOFTW MAN
[5]   EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[6]   Quantitative 1H NMR spectroscopy of blood plasma metabolites [J].
de Graaf, RA ;
Behar, KL .
ANALYTICAL CHEMISTRY, 2003, 75 (09) :2100-2104
[7]  
EVERETT JR, 1992, P 9 INT BIOAN FOR GU, P3
[8]   One-dimensional relaxation- and diffusion-edited NMR methods for screening compounds that bind to macromolecules [J].
Hajduk, PJ ;
Olejniczak, ET ;
Fesik, SW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (50) :12257-12261
[9]  
HORE PJ, 1989, METHOD ENZYMOL, V176, P64
[10]   SOLVENT PEAK SATURATION WITH SINGLE-PHASE AND QUADRATURE FOURIER TRANSFORMATION [J].
HOULT, DI .
JOURNAL OF MAGNETIC RESONANCE, 1976, 21 (02) :337-347